High resolution 3D imaging of synchrotron generated microbeams

被引:16
|
作者
Gagliardi, Frank M. [1 ,2 ]
Cornelius, Iwan [3 ,4 ]
Blencowe, Anton [5 ,6 ]
Franich, Rick D. [7 ,8 ]
Geso, Moshi [2 ]
机构
[1] The Alfred, Alfred Hlth Radiat Oncol, Melbourne, Vic 3004, Australia
[2] RMIT Univ, Sch Med Sci, Bundoora, Vic 3083, Australia
[3] Australian Synchrotron, Imaging & Med Beamline, Clayton, Vic 3168, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2500, Australia
[5] Univ S Australia, Sch Pharm & Med Sci, Div Hlth Sci, Adelaide, SA 5000, Australia
[6] Univ S Australia, Mawson Inst, Div Informat Technol Engn & Environm, Mawson Lakes, SA 5095, Australia
[7] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3000, Australia
[8] RMIT Univ, Hlth Innovat Res Inst, Melbourne, Vic 3000, Australia
关键词
MRT; microbeam imaging; PRESAGE (R) dosimeter; IntMRT; DynMRT; X-RAY MICROBEAMS; MONTE-CARLO-SIMULATION; RADIATION-THERAPY; MICROPLANAR BEAMS; MOSFET DOSIMETRY; TISSUE; BRAIN; RADIOSURGERY; RADIOTHERAPY; GLIOSARCOMA;
D O I
10.1118/1.4935410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE (R) dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE (R) dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25-50 mu m wide with 200 or 400 mu m peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A 1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 mu m/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE (R) dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:6973 / 6986
页数:14
相关论文
共 50 条
  • [1] 3D high resolution imaging of trabecular architecture by Synchrotron Radiation CT and MRI
    Peyrin, F
    Carrillon, Y
    Ludwig, W
    Beuf, O
    Barbier, B
    Laval-Jeantet, AM
    Briguet, A
    Meunier, PJ
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 983 - 983
  • [2] 3D visualization of DCIS by high resolution synchrotron CT
    Ichihara, Shu
    Ando, Masami
    Maksimenko, Anton
    Sugivania, Hiroshi
    Hashimoto, Eiko
    Yuasa, Tetsuya
    Bando, Hiroko
    Ueno, Ei
    Yamazaki, Katsuhito
    Ohbayashi, Chiho
    Hanioka, Keisuke
    MODERN PATHOLOGY, 2006, 19 : 13 - 13
  • [3] High spatial resolution scintillator dosimetry of synchrotron microbeams
    James Archer
    Enbang Li
    Jeremy Davis
    Matthew Cameron
    Anatoly Rosenfeld
    Michael Lerch
    Scientific Reports, 9
  • [4] High spatial resolution scintillator dosimetry of synchrotron microbeams
    Archer, James
    Li, Enbang
    Davis, Jeremy
    Cameron, Matthew
    Rosenfeld, Anatoly
    Lerch, Michael
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [5] MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams
    Siegbahn, E. A.
    Braeuer-Krisch, E.
    Bravin, A.
    Nettelbeck, H.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2009, 36 (04) : 1128 - 1137
  • [6] High resolution 3D imaging of bump-bonds by means of synchrotron radiation computed laminography
    Cecilia, A.
    Hamann, E.
    Koenig, T.
    Xu, F.
    Cheng, Y.
    Helfen, L.
    Ruat, M.
    Scheel, M.
    Zuber, M.
    Baumbach, T.
    Fauler, A.
    Fiederle, M.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [7] Development of 3D imaging systems using ion microbeams
    Matsuyama, Shigeo
    Hatakeyama, Taisuke
    Arai, Hirotsugu
    Kikuchi, Yohei
    Miwa, Misako
    Toyama, Sho
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 482 : 31 - 36
  • [8] High-resolution 3D imaging of tissue
    Burgess, Sean A.
    Yuan, Baohong
    Radosevich, Andrew J.
    Bouchard, Mathew B.
    Hillman, Elizabeth M. C.
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 5 - 6
  • [9] A Framework for Ultra High Resolution 3D Imaging
    Lu, Zheng
    Tai, Yu-Wing
    Ben-Ezra, Moshe
    Brown, Michael S.
    2010 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2010, : 1205 - 1212
  • [10] Ultra-high-resolution 3D digitalized imaging of the cerebral angioarchitecture in rats using synchrotron radiation
    Zhang, Meng-Qi
    Zhou, Luo
    Deng, Qian-Fang
    Xie, Yuan-Yuan
    Xiao, Ti-Qiao
    Cao, Yu-Ze
    Zhang, Ji-Wen
    Chen, Xu-Meng
    Yin, Xian-Zhen
    Xiao, Bo
    SCIENTIFIC REPORTS, 2015, 5