THE CONTAMINATION OF HOSPITAL WATER SUPPLY SYSTEMS BY LEGIONELLA PNEUMOPHILA

被引:0
|
作者
Tartakovsky, I. S. [1 ]
Gruzdeva, O. A. [2 ,3 ]
Sharapchenko, S. O. [4 ]
Gabrielyan, N., I [4 ]
机构
[1] Gamaleya Res Inst Epidemiol & Microbiol, Moscow, Russia
[2] Sechenov Univ, Moscow, Russia
[3] Ctr Hyg & Epidemiol, Moscow, Russia
[4] Shumakov Natl Med Res Ctr Transplantol & Artifici, Moscow, Russia
来源
关键词
Legionella pneumophila; legionellosis; biofilm; water biosecurity; PNEUMONIA;
D O I
10.15825/1995-1191-2021-1-125-130
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
The risk of severe infectious complications associated with provision of medical care continues to be a pressing issue in modern surgery. Legionella pneumophila, characterized by its wide distribution in water supply systems and is highly active in film formation, represents a dangerous/important cause of hospital-acquired pneumonia. Patients requiring immunosuppression, including organ transplant recipients, are in the special risk group. Prevention of hospital-acquired legionellosis in patients at risk is essential due to severe clinical manifestations and high mortality. Objective: to summarize the practical experience in detecting contamination of water supply systems by Legionella pneumophila strains in multidisciplinary hospitals in Moscow. Materials and methods. Isolation of Legionella pneumophila strains from water and biofilms of water supply systems in multidisciplinary hospitals in Moscow and serotyping of this pathogen using bacteriological, molecular genetic and enzyme immunoassay methods. Results. Legionella pneumophila content in water reached high levels. The peculiarities of Legionella pneumophila contamination of hot water supply systems included formation of stable biofilms, in which other hospital-acquired pathogens were also identified. The share of Legionella pneumophila "SG 1", which causes up to 80% legionellosis cases in the world, was 13% in the water of the hospitals surveyed. The most effective measures for prevention of legionellosis are actions aimed at ensuring water biosecurity. Conclusion. There are potential risks of disease in the surgical wards of hospitals providing medical care, including in immuno compromised patients. Due to potential risks, prevention of hospital-acquired legionellosis is a necessary component of ensuring the safety of treatment for immunosuppressed patients.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 50 条
  • [31] WATER FITTINGS AS SOURCES OF LEGIONELLA PNEUMOPHILA IN A HOSPITAL PLUMBING SYSTEM
    COLBOURNE, JS
    PRATT, DJ
    SMITH, MG
    FISHERHOCH, SP
    HARPER, D
    [J]. LANCET, 1984, 1 (8370): : 210 - 213
  • [32] The influence of contamination of a hospital hot-water system with Legionella pneumophila on serum antibody production by staff members
    Pancer, K
    Rabczenko, D
    Stypulkowska-Misiurewicz, H
    [J]. INDOOR AND BUILT ENVIRONMENT, 2006, 15 (01) : 105 - 109
  • [33] Enumeration of Legionella pneumophila in cooling tower water systems
    Türetgen, I
    Sungur, EI
    Cotuk, A
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2005, 100 (1-3) : 53 - 58
  • [34] PREVALENCE AND SIGNIFICANCE OF LEGIONELLA-PNEUMOPHILA CONTAMINATION OF RESIDENTIAL HOT-TAP WATER-SYSTEMS
    ARNOW, PM
    WEIL, D
    PARA, MF
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1985, 152 (01): : 145 - 151
  • [35] HOT WATER-SYSTEMS AS SOURCES OF LEGIONELLA-PNEUMOPHILA IN HOSPITAL AND NON-HOSPITAL PLUMBING FIXTURES
    WADOWSKY, RM
    YEE, RB
    MEZMAR, L
    WING, EJ
    DOWLING, JN
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1982, 43 (05) : 1104 - 1110
  • [36] Antibiotic susceptibility of Legionella pneumophila strains isolated from hospital water systems in Southern Italy
    De Giglio, Osvalda
    Napoli, Christian
    Lovero, Grazia
    Diella, Giusy
    Rutigliano, Serafina
    Caggiano, Giuseppina
    Montagna, Maria Teresa
    [J]. ENVIRONMENTAL RESEARCH, 2015, 142 : 586 - 590
  • [37] Nosocomial pneumonia caused by three genetically different strains of Legionella pneumophila and detection of these strains in the hospital water supply
    Lück, PC
    Wenchel, HM
    Helbig, JH
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (04) : 1160 - 1163
  • [38] Control of Legionella in a hospital potable water supply
    Williams, P
    [J]. JOURNAL OF HOSPITAL INFECTION, 1997, 37 (02) : 167 - 169
  • [39] Trend of Legionella colonization in hospital water supply
    D'Alessandro, D.
    Fabiani, M.
    Cerquetani, F.
    Orsi, G. B.
    [J]. ANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITA, 2015, 27 (02): : 460 - 466
  • [40] Control of Legionella pneumophila contamination in a respiratory hydrotherapy system with sulfurous spa water
    Leoni, E.
    Sacchetti, R.
    Zanetti, F.
    Legnani, P. P.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (07): : 716 - 721