THE CONTAMINATION OF HOSPITAL WATER SUPPLY SYSTEMS BY LEGIONELLA PNEUMOPHILA

被引:0
|
作者
Tartakovsky, I. S. [1 ]
Gruzdeva, O. A. [2 ,3 ]
Sharapchenko, S. O. [4 ]
Gabrielyan, N., I [4 ]
机构
[1] Gamaleya Res Inst Epidemiol & Microbiol, Moscow, Russia
[2] Sechenov Univ, Moscow, Russia
[3] Ctr Hyg & Epidemiol, Moscow, Russia
[4] Shumakov Natl Med Res Ctr Transplantol & Artifici, Moscow, Russia
来源
关键词
Legionella pneumophila; legionellosis; biofilm; water biosecurity; PNEUMONIA;
D O I
10.15825/1995-1191-2021-1-125-130
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
The risk of severe infectious complications associated with provision of medical care continues to be a pressing issue in modern surgery. Legionella pneumophila, characterized by its wide distribution in water supply systems and is highly active in film formation, represents a dangerous/important cause of hospital-acquired pneumonia. Patients requiring immunosuppression, including organ transplant recipients, are in the special risk group. Prevention of hospital-acquired legionellosis in patients at risk is essential due to severe clinical manifestations and high mortality. Objective: to summarize the practical experience in detecting contamination of water supply systems by Legionella pneumophila strains in multidisciplinary hospitals in Moscow. Materials and methods. Isolation of Legionella pneumophila strains from water and biofilms of water supply systems in multidisciplinary hospitals in Moscow and serotyping of this pathogen using bacteriological, molecular genetic and enzyme immunoassay methods. Results. Legionella pneumophila content in water reached high levels. The peculiarities of Legionella pneumophila contamination of hot water supply systems included formation of stable biofilms, in which other hospital-acquired pathogens were also identified. The share of Legionella pneumophila "SG 1", which causes up to 80% legionellosis cases in the world, was 13% in the water of the hospitals surveyed. The most effective measures for prevention of legionellosis are actions aimed at ensuring water biosecurity. Conclusion. There are potential risks of disease in the surgical wards of hospitals providing medical care, including in immuno compromised patients. Due to potential risks, prevention of hospital-acquired legionellosis is a necessary component of ensuring the safety of treatment for immunosuppressed patients.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 50 条
  • [1] A meta-analysis of Legionella pneumophila contamination in hospital water systems
    Fang, Zisi
    Zhou, Xiaocong
    Liao, Hui
    Xu, Hong
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2023, 51 (11) : 1250 - 1262
  • [2] LEGIONELLA-PNEUMOPHILA IN A HOSPITAL WATER-SUPPLY
    WALTER, CW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (06): : 379 - 380
  • [3] Legionella pneumophila contamination of hospital dishwashers
    Yoshida, Makiko
    Furuya, Naoko
    Hosokawa, Naoto
    Kanamori, Hajime
    Kaku, Mitsuo
    Koide, Michio
    Higa, Futoshi
    Fujita, Jiro
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2018, 46 (08) : 943 - 945
  • [4] Persistent contamination of a hospital hot water network by Legionella pneumophila
    Jeanvoine, Audrey
    Richard, Marion
    Meunier, Alexandre
    Chassagne, Sophie
    Cholley, Pascal
    Gbaguidi-Haore, Houssein
    Sauget, Marlene
    Bertrand, Xavier
    Hocquet, Didier
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2023, 250
  • [5] LEGIONELLA-PNEUMOPHILA IN A HOSPITAL WATER-SUPPLY - REPLY
    STOUT, J
    YU, VL
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1982, 307 (06): : 380 - 380
  • [6] Genetic diversity of Legionella pneumophila in hospital water systems
    Oberdorfer, Klaus
    Muessigbrodt, Grita
    Wendt, Constanze
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2008, 211 (1-2) : 172 - 178
  • [7] LEGIONELLA-PNEUMOPHILA IN A HOSPITAL POTABLE HOT WATER-SUPPLY
    WAGENVOORT, JHT
    NIEMANDSVERDRIET, PCJ
    MONNIER, C
    MICHEL, MF
    [J]. ANTONIE VAN LEEUWENHOEK JOURNAL OF MICROBIOLOGY, 1983, 49 (06): : 612 - 613
  • [8] Legionella anisa, a possible indicator of water contamination by Legionella pneumophila
    van der Mee-Marquet, N
    Domelier, AS
    Arnault, L
    Bloc, D
    Laudat, P
    Hartemann, P
    Quentin, R
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (01) : 56 - 59
  • [9] The high prevalence of Legionella pneumophila contamination in hospital potable water systems in Taiwan:: implications for hospital infection control in Asia
    Yu, Pei-Yi
    Lin, Yusen Eason
    Lin, Wei-Ru
    Shih, Hsiu-Yun
    Chuang, Yin-Ching
    Ben, Ren-Jy
    Huang, Wen-Kuei
    Chen, Yao-Shen
    Liue, Yung-Ching
    Chang, Feng-Yee
    Yen, Muh-Yong
    Liu, Ching-Chuan
    Ko, Wen-Chien
    Lin, Hsi-Hsun
    Shi, Zhi-Yuan
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2008, 12 (04) : 416 - 420
  • [10] Managing Legionella pneumophila in Water Systems
    LeChevallier, Mark W.
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2020, 112 (02): : 11 - 23