Theory of multiple-detection size-exclusion chromatography of complex branched polymers

被引:85
|
作者
Gaborieau, Marianne [1 ]
Gilbert, Robert G. [1 ]
Gray-Weale, Angus [1 ]
Hernandez, Javier M. [1 ]
Castignolles, Patrice [1 ]
机构
[1] Univ Sydney, Sch Chem F11, Key Ctr Polymer Colloids, Sydney, NSW 2006, Australia
关键词
band broadening; branching; chain; light scattering; multiple-detection size exclusion chromatography (SEC); viscometry;
D O I
10.1002/mats.200600046
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
SEC separates complex branched polymers by hydrodynamic volume, rather than by molecular weight or branching characteristics. Equations relating the response of different types of detectors are derived including band broadening, by defining a distribution function N'(M,V-h), the number of chains with molecular weight M and hydrodynamic volume V-h. While the true molecular weight distribution of complex polymers cannot be determined by SEC, irrespective of the detector used, the formalism enables multiple detection SEC data to be processed to both analyze the polymer sample and reveal mechanistic information about polymer synthesis. The formalism also shows how the true weight- and number-average molecular weight, (M) over bar (w) and (M) over bar (n), can be obtained from correct processing of the hydrodynamic volume distributions.
引用
收藏
页码:13 / 28
页数:16
相关论文
共 50 条
  • [31] Evaluation of size-exclusion chromatography and size-exclusion electrochromatography calibration curves
    Vander Heyden, Y
    Popovici, ST
    Schoenmakers, PJ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) : 127 - 137
  • [32] AN OVERVIEW OF SIZE-EXCLUSION CHROMATOGRAPHY
    JOHNSON, JF
    PLASTICS ENGINEERING, 1983, 39 (03) : 50 - 50
  • [33] ALTERNATIVES TO SIZE-EXCLUSION CHROMATOGRAPHY
    REVILLON, A
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (14-15): : 2991 - 3023
  • [34] Size-exclusion chromatography - Foreword
    Heftmann, E
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2003, 56 (1-3): : VII - VII
  • [35] Inverse Size-Exclusion Chromatography
    Sepsey, Annamaria
    Bacskay, Ivett
    Felinger, Attila
    ADVANCES IN CHROMATOGRAPHY, VOL 55, 2018, 55 : 205 - 227
  • [36] AN EXPERIMENTAL EVALUATION OF A NEW COMMERCIAL VISCOMETRIC DETECTOR FOR SIZE-EXCLUSION CHROMATOGRAPHY (SEC) USING LINEAR AND BRANCHED POLYMERS
    STYRING, MG
    ARMONAS, JE
    HAMIELEC, AE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (05): : 783 - 804
  • [37] Advanced size-exclusion chromatography and field-flow fractionation for characterization of complex synthetic polymers
    Li, Yongfu
    Bashir, Mubasher
    Meunier, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [38] Characterization of branched polysaccharides using multiple-detection size separation techniques
    Vilaplana, Francisco
    Gilbert, Robert G.
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (22) : 3537 - 3554
  • [39] Longitudinal diffusion in size-exclusion chromatography: a stop-flow size-exclusion chromatography study
    Striegel, AM
    JOURNAL OF CHROMATOGRAPHY A, 2001, 932 (1-2) : 21 - 31
  • [40] Contactless conductivity detection of synthetic polymers in non-aqueous size-exclusion electrokinetic chromatography
    Oudhoff, KA
    Macka, M
    Haddad, PR
    Schoenmakers, PJ
    Kok, WT
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1068 (01) : 183 - 187