Organic matter removal in boiler feed water treatment of a power plant with ozone

被引:6
|
作者
Rico, B [1 ]
Perez, D [1 ]
Lema, JM [1 ]
Lucas, T [1 ]
机构
[1] THERMAL POWER PLANT,AS PONTES,CORUNA,SPAIN
关键词
ozone; power plant boiler feed water; organic matter; trihalomethanes; ozone hydrogen peroxide treatment;
D O I
10.1080/01919512.1997.10382872
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this work was to test the effectiveness of ozone as a treatment to remove organic matter of the boiler feed water of a power plant. In the experiments carried out in the power plant Endesa in As Pontes (Spain), chlorine was substituted for ozone in the pre-treatment stage. The use of ozone reduced the organic content of the boiler feed water by an average 20% compared with chlorination and by 50% when ozone was combined with hydrogen peroxide. The latter treatment achieved an organic content in the boiler feed water of less than 40 mu g C/L. The ozone treatment also reduced the content of trihalomethanes in the drinking water, produced by the same plant, to values in the range of 10 mu g/L and even to undetectable values when ozone was combined with hydrogen peroxide, in spite of the postchlorination applied to this stream to ensure a disinfectant capacity though the distribution system.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 50 条
  • [21] Oxygen removal from boiler feed water by sodium sulfite
    Kobe, KA
    Gooding, WL
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1935, 27 : 331 - 333
  • [22] Removal and structural changes in natural organic matter in a Spanish water treatment plant using nascent chlorine
    Iriarte-Velasco, Unai
    Alvarez-Uriarte, Jon I.
    Gonzalez-Velasco, Juan R.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2007, 57 (01) : 152 - 160
  • [23] Removal of iron oxide scale from boiler feed-water in thermal power plant by high gradient magnetic separation: field experiment
    Akiyama, Yoko
    Li, Suqin
    Akiyama, Koshiro
    Mori, Tatsuya
    Okada, Hidehiko
    Hirota, Noriyuki
    Yamaji, Tsuyoshi
    Matsuura, Hideki
    Namba, Seitoku
    Sekine, Tomokazu
    Mishima, Fumihito
    Nishijima, Shigehiro
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2021, 23 (03): : 14 - 19
  • [24] Advanced feed water and cooling water treatment at combined cycle power plant
    Takeishi, Ryo
    Hamada, Kunihiko
    Myogan, Ichiro
    Mitsuma, Shigeo
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 469 - +
  • [25] Cyclodextrin nanosponges in the removal of organic matter to produce water for power generation
    Mamba, B. B.
    Krause, R. W.
    Malefetse, T. J.
    Gericke, G.
    Sithole, S. P.
    WATER SA, 2008, 34 (05) : 657 - 660
  • [26] Cyclodextrin nanosponges in the removal of organic matter for ultrapure water in power generation
    Mamba, B. B.
    Krause, R. W.
    Malefetse, T. J.
    Gericke, G.
    Sithole, S. P.
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2009, 58 (04): : 299 - 304
  • [27] Feed-water treatment for a modern steam boiler
    Splittgerber, A
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1935, 79 : 339 - 346
  • [28] SUBSTITUTES FOR SODA ASH IN THE TREATMENT OF BOILER FEED WATER
    TANZOLA, WA
    REED, RL
    MAGUIRE, JJ
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1947, 39 (11): : 1440 - 1443
  • [29] Treatment of a boiler feed water by a zeolite softening system
    Powell, ST
    Wolfe, JH
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1925, 17 : 584 - 585
  • [30] CONVERTER CASCADE SYSTEM FOR BOILER WATER FEED PUMPS IN THE SIMMERING POWER-PLANT (WIENER STADTWERKE)
    HASLIK, R
    ELIN ZEITSCHRIFT, 1979, 31 (04): : 132 - 139