Topology Guided Demons Registration with Local Rigidity Preservation

被引:0
|
作者
Zheng, Chaojie [1 ]
Wang, Xiuying [1 ]
Feng, Dagan [2 ]
机构
[1] Univ Sydney, Sch Informat Technol, Biomed & Multimedia Informat Technol Res Grp, Sydney, NSW, Australia
[2] Shanghai Jiao Tong Univ, Med X Res Inst, Shanghai, Peoples R China
关键词
RADIATION-THERAPY; GUIDANCE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Demons has been well recognized for its deformable registration capability. However, it might lead to misregistration due to the large spatial distance between the expected corresponding contents or erroneous diffusion tendency. In this paper, we propose a new energy function with topology energy, distance function and demons energy for deformable registration. The new energy function incorporates topological relationships to guide the correct diffusion and deformation, and contributes to local rigidity preservation. The distance function contributes to pulling the corresponding regions into accurate alignment despite of a possible large distance gap. The method was validated on synthetic, phantom and real medical image data.
引用
收藏
页码:1171 / 1174
页数:4
相关论文
共 50 条
  • [21] TOPOLOGY PRESERVATION FOR IMAGE-REGISTRATION-RELATED DEFORMATION FIELDS
    Ozere, Solene
    Le Guyader, Carole
    COMMUNICATIONS IN MATHEMATICAL SCIENCES, 2015, 13 (05) : 1135 - 1161
  • [22] Topology Preservation and Anatomical Feasibility in Random Walker Image Registration
    Andrews, Shawn
    Tang, Lisa
    Hamarneh, Ghassan
    Medical Image Computing and Computer-Assisted Intervention - MICCAI 2014, Pt I, 2014, 8673 : 210 - 217
  • [23] ON THE TOPOLOGY PRESERVATION PROPERTY OF LOCAL PARALLEL OPERATIONS
    KAWAI, S
    COMPUTER GRAPHICS AND IMAGE PROCESSING, 1982, 19 (03): : 265 - 280
  • [24] Nonrigid registration using regularization that accommodates local tissue rigidity
    Ruan, Dan
    Fessler, Jeffrey A.
    Roberson, Michael
    Balter, James
    Kessler, Marc
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [25] Deformable registration using regularization that accommodates local tissue rigidity
    Ruan, D.
    Fessler, J.
    Roberson, M.
    Balter, J.
    Kessler, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2186 - 2186
  • [26] Demons deformable registration for CBCT-guided procedures in the head and neck: Convergence and accuracy
    Nithiananthan, S.
    Brock, K. K.
    Daly, M. J.
    Chan, H.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2009, 36 (10) : 4755 - 4764
  • [27] TOPOLOGY QUASI-PRESERVATION BY LOCAL PARALLEL OPERATIONS
    KAWAI, S
    COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1983, 23 (03): : 353 - 365
  • [28] Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
    Koenig, Lars
    Derksen, Alexander
    Papenberg, Nils
    Haas, Benjamin
    RADIATION ONCOLOGY, 2016, 11
  • [29] Improved Demons Three-Dimensional Registration Algorithm and the Application in Image-Guided Radiotherapy
    Wu, Qian
    Pi, Yifei
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (09) : 1887 - 1891
  • [30] Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
    Lars König
    Alexander Derksen
    Nils Papenberg
    Benjamin Haas
    Radiation Oncology, 11