The Calculation of Corona Inception Electric Field of HVDC Conductors

被引:0
|
作者
Han, Shaowei [1 ]
Lu, Tiebing [1 ]
Zhao, Zhibin [1 ]
机构
[1] N China Elect Power Univ, Sch Elect & Elect Engn, Baoding 071003, Peoples R China
关键词
HVDC; corona; CSM; corona inception electric field; corona inception voltage; DIGITAL-COMPUTER CALCULATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper calculates the single conductor corona inception voltage and corona inception electric field based on a corona inception voltage criterion. The calculated results agree with the results of Peek formula well. At the same time this paper analyzes the effect of air pressure, temperature and height above sea level on the corona inception voltage and corona inception electric field. It is found that the single conductor corona inception voltage and corona inception electric field become lower when the air pressure decreases, which is not good for electrical environment.
引用
收藏
页码:3377 / 3380
页数:4
相关论文
共 50 条
  • [41] Experimental Study on Impulse Corona Characteristics of HVDC Conductors With Space Charges
    Xiao, Fengnyu
    Zhang, Bo
    Deng, Yaqiang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1705 - 1713
  • [42] Polarity Effect on Electric Tree Inception in HVDC Cable Insulation
    Kumara, Sarath
    Hammarstrom, Thomas
    Serdyuk, Yuriy, V
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (05) : 1819 - 1827
  • [43] Positive dc corona inception on dielectric-coated stranded conductors in air
    Yi, Yong
    Zhang, Chuyan
    Wang, Liming
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (06) : 557 - 563
  • [44] DC positive corona inception performances of stranded conductors and its affecting factors
    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China
    Zhongguo Dianji Gongcheng Xuebao, 2009, 34 (108-114): : 108 - 114
  • [45] Effect of atmospheric factors on AC corona inception voltage of conductors and its correction
    Hu, Qin
    Shu, Lichun
    Jiang, Xingliang
    Sun, Caixin
    Yuan, Qianfei
    Yang, Zhangang
    Dianwang Jishu/Power System Technology, 2010, 34 (11): : 70 - 76
  • [46] Analysis on altitude correction factor of corona inception voltage/electric field of AC transmission lines using the mobile corona cage
    Chen, Yong
    Xie, Xiong-Jie
    Bian, Xing-Ming
    Liu, Yun-Peng
    Zhou, Wen-Jun
    Wang, Li-Ming
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (06): : 1385 - 1391
  • [47] CALCULATION OF ELECTRIC FIELD AND CHARGE DENSITY FOR BIPOLAR HVDC TRANSMISSION LINE.
    Fujioka, Nobuhiro
    Shiota, Tadahiro
    Fujiwara, Emilio
    Tsunoda, Yoshihiro
    1600, (107):
  • [48] Application of a corona onset criterion to calculation of corona onset voltage of stranded conductors
    Yamazaki, K
    Olsen, RG
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2004, 11 (04) : 674 - 680
  • [49] Total Electric Field Calculation of Body Model under HVDC Transmission Lines
    Zhen, Yongzan
    Cui, Xiang
    Lu, Tiebing
    Luo, Zhaonan
    Zhou, Xiangxian
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [50] CALCULATION OF ELECTRIC FIELD AND ION CURRENT DENSITY FOR BIPOLAR HVDC LINE.
    Fu Binlan
    1600, (07):