Comparison of thermal insulation performance of vacuum insulation panels with EPS protection layers measured with different methods

被引:38
|
作者
Lakatos, Akos [1 ]
Kovacs, Zsolt [2 ]
机构
[1] Univ Debrecen, Fac Engn, Dept Bldg Serv & Bldg Engn, Debrecen Otemeto Str 2-4, H-4028 Debrecen, Hungary
[2] INOX THERM Kft, Honved Str 8-1 2, H-1054 Budapest, Hungary
关键词
Hot box method; U-value; Vacuum insulation panels; Thermal insulation; SERVICE LIFE; VIPS; VERIFICATION;
D O I
10.1016/j.enbuild.2021.110771
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For reducing the energy use of buildings, the application of insulation materials can be a possible solution to improve energy efficiency. However, with the continuously tightening regulations, thicker and thicker insulations should be used (e.g., up to 20?25 cm in Hungary and about 40?50 cm in the Nordic countries) to fulfil the directives. In the past decades, developmental research started to focus on both decreasing the thickness and decreasing the thermal conductivity of materials parallels. With this research direction, the investigations of the new type of insulation materials took place. The use of materials having thermal conductivity with less than 0.020 W/mK spread over. These materials are the so-called super insulation materials. Besides Vacuum Insulation Panels (VIPs), aerogel-based materials belong to this group, too. This paper will present laboratory tests executed on two altered types of protected Vacuum Insulation Panels: a one side and a 2 side protected VIP, also called Vacuum Insulation Sandwich (VIS). The first one, type ?A? contains 20 mm thick laminated fumed silica, covered with 10 mm thick expanded polystyrene on one side, while type ?B? was the one where the 10 mm thick laminated fumed silica core was packed between two 10 mm thick EPS slabs. Firstly, thermal insulation performance was investigated by the so-called guarded hot-box method for U-value, where the samples were placed on a solid brick wall. Furthermore, the thermal insulation performance of protected VIPs was also tested with Hukseflux heat flux plates. To reveal the applicability limits caused by the thermal bridges infrared thermography images (IR) were taken, too. From the images and the measurement results, a theory was formed regarding the heat flow directions inside the encapsulated panels. The current article emphasizes the equivalent thermal conductivity for the assessment of the thermal protection performance of vacuum insulation panels. The paper states that by using VIPs at least, 70% reduction can be reached in the Uvalue compared to the value of the solid brick wall. Moreover, the paper points out that the use of EPS protection layer on both sides of the VIP has a promising effect by reducing the thermal bridges. Furthermore, the VIP protected with EPS slabs on both sides results in less equivalent thermal conductivity. ? 2021 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license For reducing the energy use of buildings, the application of insulation materials can be a possible solution to improve energy efficiency. However, with the continuously tightening regulations, thicker and thicker insulations should be used (e.g., up to 20-25 cm in Hungary and about 40-50 cm in the Nordic countries) to fulfil the directives. In the past decades, developmental research started to focus on both decreasing the thickness and decreasing the thermal conductivity of materials parallels. With this research direction, the investigations of the new type of insulation materials took place. The use of materials having thermal conductivity with less than 0.020 W/mK spread over. These materials are the so-called super insulation materials. Besides Vacuum Insulation Panels (VIPs), aerogel-based materials belong to this group, too. This paper will present laboratory tests executed on two altered types of protected Vacuum Insulation Panels: a one side and a 2 side protected VIP, also called Vacuum Insulation Sandwich (VIS). The first one, type "A" contains 20 mm thick laminated fumed silica, covered with 10 mm thick expanded poly-styrene on one side, while type "B" was the one where the 10 mm thick laminated fumed silica core was packed between two 10 mm thick EPS slabs. Firstly, thermal insulation performance was investi-gated by the so-called guarded hot-box method for U-value, where the samples were placed on a solid brick wall. Furthermore, the thermal insulation performance of protected VIPs was also tested with Hukseflux heat flux plates. To reveal the applicability limits caused by the thermal bridges infrared ther-mography images (IR) were taken, too. From the images and the measurement results, a theory was formed regarding the heat flow directions inside the encapsulated panels. The current article emphasizes the equivalent thermal conductivity for the assessment of the thermal protection performance of vacuum insulation panels. The paper states that by using VIPs at least, 70% reduction can be reached in the U-value compared to the value of the solid brick wall. Moreover, the paper points out that the use of EPS protection layer on both sides of the VIP has a promising effect by reducing the thermal bridges. Furthermore, the VIP protected with EPS slabs on both sides results in less equivalent thermal conductivity. (c) 2021 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Analysis of the temperature dependence of the thermal conductivity in Vacuum Insulation Panels
    Fantucci, Stefano
    Lorenzati, Alice
    Capozzoli, Alfonso
    Perino, Marco
    ENERGY AND BUILDINGS, 2019, 183 : 64 - 74
  • [22] A study on thermal bridge effect of vacuum insulation panels (VIPs)
    Liang, Weitao
    Di, Xiaobo
    Zheng, Shukui
    Wu, Leyu
    Zhang, Jianjun
    JOURNAL OF BUILDING ENGINEERING, 2023, 71
  • [23] Subtle issues in the measurement of the thermal conductivity of vacuum insulation panels
    Wessling, FC
    Moser, MD
    Blackwood, JM
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2004, 126 (02): : 155 - 160
  • [24] Building application and thermal performance of vacuum insulation panels (VIPs) in Canadian subarctic climate
    Mukhopadhyaya, P.
    MacLean, D.
    Korn, J.
    van Reenen, D.
    Molleti, S.
    ENERGY AND BUILDINGS, 2014, 85 : 672 - 680
  • [25] Vacuum Insulation Panels: thermal bridging effects and energy performance in real building applications
    Isaia, Francesco
    Fantucci, Stefano
    Capozzoli, Alfonso
    Perino, Marco
    SUSTAINABILITY IN ENERGY AND BUILDINGS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE SEB-15, 2015, 83 : 269 - 278
  • [26] Experimental and theoretical thermal performance analysis of additively manufactured polymer vacuum insulation panels
    Pei, Yong
    Shen, Ziyang
    Zhou, Jian
    Yang, Bao
    APPLIED THERMAL ENGINEERING, 2024, 256
  • [27] Vacuum Insulation Panels: Analysis of the Thermal Performance of Both Single Panel and Multilayer Boards
    Capozzoli, Alfonso
    Fantucci, Stefano
    Favoino, Fabio
    Perino, Marco
    ENERGIES, 2015, 8 (04) : 2528 - 2547
  • [28] The effect of temperature on thermal performance of fumed silica based Vacuum Insulation Panels for buildings
    Lorenzati, Alice
    Fantucci, Stefano
    Capozzoli, Alfonso
    Perino, Marco
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 500 - 509
  • [29] Functionalising kapok fibre with lignin to enhance the structural and thermal performance of vacuum insulation panels
    Sun, Qianqian
    Chen, Jingming
    Xu, Jun
    Zhang, Zhaohui
    Zhu, Shiyun
    Li, Jun
    Chen, Kefu
    Fan, Mizi
    INDUSTRIAL CROPS AND PRODUCTS, 2024, 220
  • [30] The effects of PE additive on the performance of polystyrene vacuum insulation panels
    Tseng, P. C.
    Chu, H. S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (13-14) : 3084 - 3090