Investigation of Depth of Interaction Encoding for a Pixelated LSO Array With a Single Multi-Channel PMT

被引:25
|
作者
Yang, Yongfeng [1 ]
Wu, Yibao [1 ]
Cherry, Simon R. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
Depth of interaction; positron emission tomography (PET); small-animal imaging; SMALL-ANIMAL PET; RESOLUTION RESEARCH TOMOGRAPH; POSITRON-EMISSION-TOMOGRAPHY; PERFORMANCE EVALUATION; DETECTOR MODULE; MICROPET SCANNER; IMAGING-SYSTEM; ECAT HRRT; DESIGN; ACQUISITION;
D O I
10.1109/TNS.2009.2016094
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new approach to depth or interaction (DOI) encoding for a pixelated LSO array using a single multi-channel PMT was investigated. In this method the DOI information was estimated by taking advantage of optical crosstalk between LSO elements and examining the standard deviation (spread) of signals on all channels of the PMT. Unpolished and polished 6 x 6 LSO arrays with a crystal size of 1.3 x 1.3 x 20 mm(3) were evaluated on a Hamamatsu H7546 64-channel PMT. The arrays were placed on the center of the PMT and the central 16 channels of the PMT were individually read out and digitized. For the unpolished array, all crystals were resolved in the flood histogram. An average DOI resolution of 8 mm was obtained. The energy resolution was similar to 25% after the signal amplitude was corrected using the measured DOI information. For the polished array, the flood histo-ram was superior to the unpolished array, however no DOI information could be measured. Using unpolished crystals, this method could be a practical way to achieve limited DOI information in PET detectors. The standard deviation of all PMT channels can be readily obtained using a resistor network. Only five signals (four signals to determine the x-y position and one signal measuring the standard deviation) need to be digitized, and this method only requires a single photon detector to read out the array. Unlike phoswich detectors, the method does not require segmenting the scintillator array into layers. The measured DOI resolution was much worse than that obtained with the dual-ended readout method, however, it was similar to that obtained with a two-layer phoswich detector.
引用
收藏
页码:2594 / 2599
页数:6
相关论文
共 50 条
  • [41] Development of a Multi-Channel Array Resistivity Method Instrument System
    Zeng, Weihua
    Zhang, Jingjing
    Tan, Handong
    Hou, Shengli
    IEEE Transactions on Instrumentation and Measurement, 2022, 71
  • [42] Suppression of the optical crosstalk in a multi-channel silicon photomultiplier array
    Masuda, Takahiko
    Ang, Daniel G.
    Hutzler, Nicholas R.
    Meisenhelder, Cole
    Sasao, Noboru
    Uetake, Satoshi
    Wu, Xing
    DeMille, David
    Gabrielse, Gerald
    Doyle, John M.
    Yoshimura, Koji
    OPTICS EXPRESS, 2021, 29 (11) : 16914 - 16926
  • [43] Multi-channel transimpedance measurement of a planar electromagnetic sensor array
    Chen, Dixiang
    Xie, Ruifang
    Zhou, Weihong
    Hu, Hengjiang
    Pan, Mengchun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (02)
  • [44] Note: An underwater multi-channel plasma array for water sterilization
    Yang, Y.
    Kim, H.
    Starikovskiy, A.
    Cho, Y. I.
    Fridman, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (09):
  • [45] MULTI-CHANNEL CORRELATOR ARRAY-FED MICROWAVE RADIOMETER
    Piepmeier, Jeffrey R.
    Mahnad, Ali
    De Amici, Giovanni
    Peng, Jinzheng
    Jordan, Jared
    Vanhille, Ken
    Holmes, Thomas
    Racette, Paul
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 8419 - 8422
  • [46] Development of a Multi-Channel Array Resistivity Method Instrument System
    Zeng, Weihua
    Zhang, Jingjing
    Tan, Handong
    Hou, Shengli
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [47] Multi-channel laser diode driver array and its application
    Tan, QS
    Vandewege, J
    FIBER OPTIC COMPONENTS AND OPTICAL COMMUNICATION, 1996, 2893 : 308 - 317
  • [48] Antenna array calibration for a multi-channel direction of arrival sounder
    Lewenz, R
    Filippidis, P
    Salous, S
    2001 HIGH FREQUENCY POSTGRADUATE STUDENT COLLOQUIUM, 2001, : 119 - 124
  • [49] Multi-channel data acquisition using multiplexed imaging with spatial encoding
    Horisaki, Ryoichi
    Tanida, Jun
    OPTICS EXPRESS, 2010, 18 (22): : 23041 - 23053
  • [50] Spatial resolution and depth-of-interaction studies with a PET detector module composed of LSO and an APD array
    Fremout, AAR
    Chen, RR
    Bruyndonckx, P
    Tavernier, SPK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 131 - 138