CT imaging of extraglottic airway device-pictorial review

被引:0
|
作者
Norii, Tatsuya [1 ]
Makino, Yohsuke [2 ]
Unuma, Kana [3 ]
Adolphi, Natalie L. [4 ]
Albright, Danielle [1 ]
Sklar, David P. [5 ]
Crandall, Cameron [1 ]
Braude, Darren [1 ,6 ]
机构
[1] Univ New Mexico, Hlth Sci Ctr, Dept Emergency Med, MSC11 6025 Lomas Blvd NE, Albuquerque, NM 87131 USA
[2] Univ Tokyo, Dept Forens Med, Tokyo, Japan
[3] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Forens Med, Tokyo, Japan
[4] Univ New Mexico, Hlth Sci Ctr, Dept Biochem & Mol Biol, Ctr Forens Imaging, Albuquerque, NM 87131 USA
[5] Arizona State Univ, Coll Hlth Solut, Phoenix, AZ USA
[6] Univ New Mexico, Hlth Sci Ctr, Dept Anesthesiol, Albuquerque, NM 87131 USA
关键词
Extraglottic airway device; Misplacement; Resuscitation; Airway management;
D O I
10.1007/s10140-021-01909-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Compared to intubation with a cuffed endotracheal tube, extraglottic airway devices (EGDs), such as laryngeal mask airways, are considered less definitive ventilation conduit devices and are therefore often exchanged via endotracheal intubation (ETI) prior to obtaining CT images. With more widespread use and growing comfort among providers, reports have now described use of EGDs for up to 24 h including cases for which clinicians obtained CT scans with an EGD in situ. The term EGD encompasses a wide variety of devices with more complex structure and CT appearance compared to ETI. All EGDs are typically placed without direct visualization and require less training and time for insertion compared to ETI. While blind insertion generally results in functional positioning, numerous studies have reported misplacements of EGDs identified by CT in the emergency department or post-mortem. A CT-based classification system has recently been suggested to categorize these misplacements in six dimensions: depth, size, rotation, device kinking, mechanical blockage of the ventilation opening(s), and injury from EGD placement. Identifying the type of EGD and its correct placement is critically important both to provide prompt feedback to clinicians and prevent inappropriate medicolegal problems. In this review, we introduce the main types of EGDs, demonstrate their appearance on CT images, and describe examples of misplacements.
引用
收藏
页码:665 / 673
页数:9
相关论文
共 50 条
  • [21] Extraglottic Airway Device Misplacement: A Novel Classification System and Findings in Postmortem Computed Tomography
    Norii, Tatsuya
    Makino, Yohsuke
    Unuma, Kana
    Hatch, Gary M.
    Adolphi, Natalie L.
    Dallo, Sarah
    Albright, Danielle
    Sklar, David P.
    Braude, Darren
    ANNALS OF EMERGENCY MEDICINE, 2021, 77 (03) : 285 - 295
  • [22] The Baska® Mask - A New Extraglottic Airway Device with Two Gastric Drains - A Feasibility Study
    van Zundert, Tom
    Gatt, Stephen
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 253 - 254
  • [23] Extraglottic device use is rare during emergency airway management: A National Emergency Airway Registry (NEAR) study
    April, Michael D.
    Driver, Brian
    Schauer, Steven G.
    Carlson, Jestin N.
    Bridwell, Rachel E.
    Long, Brit
    Stang, Jamie
    Farah, Subrina
    Lorenzo, Robert A. De
    Brown III, Calvin A.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2023, 72 : 95 - 100
  • [24] CT imaging for left atrial appendage closure: A review and pictorial essay
    Ismail, Teufik Fehmi
    Panikker, Sandeep
    Markides, Vias
    Foran, John P.
    Padley, Simon
    Rubens, Michael B.
    Wong, Tom
    Nicol, Edward
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (02) : 89 - 102
  • [25] CT and MR imaging of gastrointestinal stromal tumor of stomach: a pictorial review
    Gong, Jingshan
    Kang, Wenyan
    Zhu, Jin
    Xu, Jianmin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2012, 2 (04) : 274 - 279
  • [26] Pancreatic congenital anomalies and their features on CT and MR imaging: a pictorial review
    Amseian, Gary
    Ayuso, Juan-Ramon
    ABDOMINAL RADIOLOGY, 2024, 49 (05) : 1734 - 1746
  • [27] Pictorial review of SPECT/CT imaging applications in clinical nuclear medicine
    Bhargava, Peeyush
    He, Guocheng
    Samarghandi, Amin
    Delpassand, Ebrahim S.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 2 (02): : 221 - 231
  • [28] Evolution of the Extraglottic Airway: A Review of Its History, Applications, and Practical Tips for Success
    Hernandez, Michael R.
    Klock, P. Allan, Jr.
    Ovassapian, Adranik
    ANESTHESIA AND ANALGESIA, 2012, 114 (02): : 349 - 368
  • [29] Multi-detector computed tomography imaging of large airway pathology: A pictorial review
    Jugpal, Tejeshwar Singh
    Garg, Anju
    Sethi, Gulshan Rai
    Daga, Mradul Kumar
    Kumar, Jyoti
    WORLD JOURNAL OF RADIOLOGY, 2015, 7 (12): : 459 - 474
  • [30] Antenatal imaging: A pictorial review
    Bunyamin Ece
    Sonay Ayd?n
    Mecit Kantarci
    World Journal of Clinical Cases, 2022, (35) : 12854 - 12874