Use of automated home blood pressure monitoring in pregnancy: Is it safe?

被引:35
|
作者
Lo, C
Taylor, RS
Gamble, G
McCowan, L
North, RA
机构
[1] Univ Auckland, Dept Obstet & Gynecol, Auckland 1, New Zealand
[2] Univ Auckland, Dept Med, Auckland 1, New Zealand
关键词
blood pressure monitoring; oscillometric monitor; pregnancy; preeclampsia;
D O I
10.1067/mob.2002.126847
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: The purpose of this study was to investigate the relationship between blood pressure that is measured with the automated blood pressure monitor, Omron HEM-705CP (Omron Corporation, Tokyo, Japan), and mercury sphygmomanometry in normotensive and preeclamptic pregnant women. STUDY DESIGN: Healthy pregnant women (n = 101 women) underwent mercury and home Omron HEM-705CP monitor blood pressure measurements at 10 to 14, 19 to 22, 27 to 30, and 35 to 37 weeks of gestation and 5 to 9 weeks after delivery. After routine mercury blood pressure recordings that were taken by midwives, women with preeclampsia (n = 45 women) measured their own blood pressure using an Omron HEM-705CP monitor (n = 212 recordings). In the longitudinal cohort, mean +/- 2 SD were calculated for blood pressure levels throughout pregnancy. Individual variation in home Omron minus office mercury throughout pregnancy was determined. In preeclampsia, back-to-back blood pressure measurements by the two methods were correlated and quantified as being within 5, 10, and 15 mm Hg. Bland-Altman plots were calculated, and the sensitivity of the Omron HEM-705CP monitor to detect hypertension that was identified by mercury sphygmomanometry was evaluated. RESULTS: At 10 to 14, 19 to 22, 27 to 30, and 35 to 37 weeks of gestation, the upper limits for normal systolic blood pressure levels with the use of home Omron HEM-705CP monitor measurements were 132, 130, 133, and 138 mm Hg and for diastolic blood pressure levels were 82, 79, 81, and 88 mm Hg, respectively. For women who were normotensive and had preeclampsia (although group mean blood pressure values by mercury sphygmomanometry and Omron HEM-705CP monitor were similar), there were marked individual differences (! 40 mm Hg) between the devices. In preeclampsia, paired Omron monitor and mercury systolic and diastolic blood pressure levels were within 5, 10, and 15 mm Hg in 47%, 73%, and 82%, and 56%, 78%, and 92%, respectively. The Omron monitor identified > 90% of mild hypertension (140/90 mm Hg) but missed one third of hypertension with a blood pressure level of > 160/100 mm Hg by mercury sphygmomanometry. CONCLUSION: Clinicians should be aware of the potential differences between blood pressure measurements with mercury sphygmomanometers and Omron HEM-705CP monitors in pregnancy. The Omron HEM-705CP monitor should not be used to monitor hypertension in preeclampsia.
引用
收藏
页码:1321 / 1328
页数:8
相关论文
共 50 条
  • [41] Blood pressure monitoring during pregnancy
    Feldman, DM
    BLOOD PRESSURE MONITORING, 2001, 6 (01) : 1 - 7
  • [42] AUTOMATED BLOOD-PRESSURE RECORDING IN PREGNANCY
    BROWN, MA
    ADSETT, D
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART B-HYPERTENSION IN PREGNANCY, 1991, 10 (1-2): : 7 - 19
  • [43] AUTOMATED BLOOD-PRESSURE MEASUREMENT IN PREGNANCY
    MARX, GF
    SCHWALBE, SS
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (02) : 703 - 703
  • [44] Accuracy of automated blood pressure recorders in pregnancy
    Brown, MA
    Robinson, A
    Buddle, ML
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1998, 38 (03): : 262 - 265
  • [45] Out-of-Office Blood Pressure Monitoring: A Comparison of Ambulatory Blood Pressure Monitoring and Home (Self) Monitoring Of Blood Pressure
    Townsend, Raymond R.
    HYPERTENSION, 2020, 76 (06) : 1667 - 1673
  • [46] Home blood pressure during normal pregnancy
    Denolle, T
    Daniel, JC
    Calvez, C
    Ottavioli, JN
    Esnault, V
    Herpin, D
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (09) : 1178 - 1180
  • [47] Home Blood Pressure Monitoring and Blood Pressure Control in Treated Hypertensives
    Brandao, Andrea Araujo
    Sebba Barroso, Weimar Kunz
    Feitosa, Audes
    Duarte Barbosa, Eduardo Costa
    Miranda, Roberto Dischinger
    de Oliveira Vitorino, Priscila Valverde
    Pozzan, Roberto
    Ribeiro, Lucio Paulo
    Epelman, Abraham
    Saraiva, Giovanni Alves
    Silveira, Fabio Serra
    Braga, Antonio Almeida
    Gomes, Marco Mota
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2022, 119 (02) : 353 - 357
  • [48] Reduced Medical Spending Overtime With Use of a Home Blood Pressure Monitoring Program
    James, Roberta
    Lu, Wei
    Schnieder, Jennifer
    Shah, Bimal R.
    CIRCULATION, 2020, 142
  • [49] DOES THE USE OF HOME BLOOD PRESSURE MONITORING VARY BY RACE, EDUCATION, AND INCOME?
    Poon, Ivy O.
    Etti, Nicole
    Lal, Lincy S.
    ETHNICITY & DISEASE, 2010, 20 (01) : 2 - 6
  • [50] Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension
    Manning, G