Water quality modeling in the dead end sections of drinking water distribution networks

被引:69
|
作者
Abokifa, Ahmed A. [1 ]
Yang, Y. Jeffrey [2 ]
Lo, Cynthia S. [1 ]
Biswas, Pratim [1 ]
机构
[1] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
[2] US EPA, Off Res & Dev, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA
关键词
Chlorine; Dead end pipe; Advection dispersion; Genetic algorithm; Stochastic demands; Spatial distribution; Correction factors; CHLORINE CONCENTRATION DECAY; CONSTITUENT TRANSPORT; SIMULATION; FLOWS;
D O I
10.1016/j.watres.2015.11.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dead-end sections of drinking water distribution networks are known to be problematic zones in terms of water quality degradation. Extended residence time due to water stagnation leads to rapid reduction of disinfectant residuals allowing the regrowth of microbial pathogens. Water quality models developed so far apply spatial aggregation and temporal averaging techniques for hydraulic parameters by assigning hourly averaged water demands to the main nodes of the network. Although this practice has generally resulted in minimal loss of accuracy for the predicted disinfectant concentrations in main water transmission lines, this is not the case for the peripheries of the distribution network. This study proposes a new approach for simulating disinfectant residuals in dead end pipes while accounting for both spatial and temporal variability in hydraulic and transport parameters. A stochastic demand generator was developed to represent residential water pulses based on a non-homogenous Poisson process. Dispersive solute transport was considered using highly dynamic dispersion rates. A genetic algorithm was used to calibrate the axial hydraulic profile of the dead-end pipe based on the different demand shares of the withdrawal nodes. A parametric sensitivity analysis was done to assess the model performance under variation of different simulation parameters. A group of Monte-Carlo ensembles was carried out to investigate the influence of spatial and temporal variations in flow demands on the simulation accuracy. A set of three correction factors were analytically derived to adjust residence time, dispersion rate and wall demand to overcome simulation error caused by spatial aggregation approximation. The current model results show better agreement with field-measured concentrations of conservative fluoride tracer and free chlorine disinfectant than the simulations of recent advection dispersion reaction models published in the literature. Accuracy of the simulated concentration profiles showed significant dependence on the spatial distribution of the flow demands compared to temporal variation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:107 / 117
页数:11
相关论文
共 50 条
  • [31] Assessing water quality of drinking water distribution system in the South Taiwan
    Lou, Jie-Chung
    Han, Jia-Yun
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 134 (1-3) : 343 - 354
  • [32] Copper corrosion in drinking water distribution systems - the influence of water quality
    Dept of Inorganicf Chemistry, University of Goteborg, Sweden
    Corros Sci, 6 (1119-1132):
  • [33] Assessing water quality of drinking water distribution system in the South Taiwan
    Jie-Chung Lou
    Jia-Yun Han
    Environmental Monitoring and Assessment, 2007, 134 : 343 - 354
  • [34] Copper corrosion in drinking water distribution systems - The influence of water quality
    Broo, AE
    Berghult, B
    Hedberg, T
    CORROSION SCIENCE, 1997, 39 (06) : 1119 - 1132
  • [35] Automated water quality monitoring in water distribution networks
    Papadimitrakis, YA
    INTEGRATED TECHNOLOGIES FOR ENVIRONMENTAL MONITORING AND INFORMATION PRODUCTION, 2003, 23 : 103 - 118
  • [36] Adaptive control of water quality in water distribution networks
    Wang, Z
    Polycarpou, MM
    Uber, JG
    Shang, F
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2006, 14 (01) : 149 - 156
  • [37] A framework for assessing uncertainty of drinking water quality in distribution networks with application to monochloramine decay
    Frankel, Matthew
    Katz, Lynn E.
    Kinney, Kerry
    Werth, Charles J.
    Zigler, Corwin
    Sela, Lina
    JOURNAL OF CLEANER PRODUCTION, 2023, 407
  • [38] Saphir: An optimising tool on drinking water distribution networks
    Kora, R
    Fotoohi, F
    Konstantopedos, K
    HYDROINFORMATICS '96, VOLS 1 AND 2, 1996, : 901 - 904
  • [39] Impact of Pressure on the Deterioration of Drinking Water Distribution Networks
    Rjaibi, Amira
    Duchesne, Sophie
    WATER RESOURCES MANAGEMENT, 2024, 38 (12) : 4867 - 4882
  • [40] Modeling and Optimization of Production and Distribution of Drinking Water at VMW
    Verleye, Derek
    Aghezzaf, El-Houssaine
    NETWORK OPTIMIZATION, 2011, 6701 : 315 - 326