Development and Validation of a Predictive Model for Hemodynamic Responses to Resuscitation during Uncontrolled Hemorrhage

被引:0
|
作者
Reisner, Nicholas W. [1 ]
Peterson, Jeffrey T. [2 ]
Dubick, Michael A. [3 ]
Reisner, Andrew T. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Emergency Med, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
[3] US Army, Inst Surg Res, San Antonio, TX 78234 USA
关键词
BLOOD-PRESSURE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigated whether a statistical model could predict mean arterial pressure (MAP) during uncontrolled hemorrhage; such a model could be used for automated decision support, to help clinicians decide when to provide intravascular volume to achieve MAP goals. This was a secondary analysis of adult swine subjects during uncontrolled splenic bleeding. By protocol, after developing severe hypotension (MAP < 60 mmHg), subjects were resuscitated with either saline (NS) or fresh frozen plasma (FFP), determined randomly. Vital signs were documented at quasi-regular time-step intervals, until either subject death or 300 min. Subjects were randomly separated 50%/50% into training/validation sets, and regression models were developed to predict MAP for each subsequent (i.e., future) time-step. Median time-steps for serially recorded vital signs were +15 min. 5 subjects survived the protocol; 17 died after a median time of 87 min (IQR 78 - 134). The final model consisted of: current MAP; heart rate (HR); prior NS; imminent NS; and imminent FFP. The 95% limits-of-agreement between true subsequent MAP vs. predicted subsequent MAP were +10/-11 mmHg for the 79 time-steps in the training set; and +14/-13 for the 64 time-steps in the validation set. A total of 10 sudden death events (i.e., rapid, fatal MAP decrease within one single time-step) were excluded from analysis. In conclusion, for uncontrolled hemorrhage in a swine model, it was possible to estimate the next documented MAP value on the basis of the subject's current documented MAP; HR; prior NS; and the volume of resuscitation about to be administered. However, the model was unable to predict "sudden death" events. The applicability to populations with wider heterogeneity of hemorrhage patterns and with comorbidities requires further investigation.
引用
收藏
页码:4978 / 4981
页数:4
相关论文
共 50 条
  • [31] Peripheral Chemoreceptors Hemodynamic Responses During Simulated Hemorrhage Under Hypoxia Conditions
    Shepherd, John
    Baker, Sarah
    Holbein, Walter
    Limberg, Jacqueline
    Johnson, Blair
    Schroeder, Darrell
    Curry, Timothy
    Convertino, Victor
    Joyner, Michael
    FASEB JOURNAL, 2020, 34
  • [32] Hemodynamic responses and serum nitrite concentration during uncontrolled hemorrhagic shock in normotensive and hypertensive rats
    Khazaei, Majid
    Barmaki, Babak
    Nasimi, Ali
    BIOMEDICAL PAPERS-OLOMOUC, 2012, 156 (03): : 224 - 228
  • [33] A severe vicious cycle in uncontrolled subarachnoid hemorrhage: the effects on cerebral blood flow and hemodynamic responses upon intracranial hypertension
    Su, CF
    Yang, YL
    Lee, MC
    Chen, HI
    CHINESE JOURNAL OF PHYSIOLOGY, 2006, 49 (01): : 56 - 63
  • [34] DEVELOPMENT OF A NONHUMAN PRIMATE (RHESUS MACAQUE) MODEL OF UNCONTROLLED TRAUMATIC LIVER HEMORRHAGE
    Sheppard, Forest R.
    Macko, Antoni
    Fryer, Darren M.
    Ozuna, Kassandra M.
    Brown, Alexander K.
    Crossland, Randy F.
    Tadaki, Douglas K.
    SHOCK, 2015, 44 : 114 - 122
  • [35] METABOLIC ACIDEMIA WITH HYPOXIA ATTENUATES THE HEMODYNAMIC-RESPONSES TO EPINEPHRINE DURING RESUSCITATION IN LAMBS
    PREZIOSI, MP
    ROIG, JC
    HARGROVE, N
    BURCHFIELD, DJ
    CRITICAL CARE MEDICINE, 1993, 21 (12) : 1901 - 1907
  • [36] Development of a Large Animal Model for Investigating Resuscitation After Blast and Hemorrhage
    Garner, J. P.
    Watts, S.
    Parry, C.
    Bird, J.
    Kirkman, E.
    WORLD JOURNAL OF SURGERY, 2009, 33 (10) : 2194 - 2202
  • [37] Development of a Large Animal Model for Investigating Resuscitation After Blast and Hemorrhage
    J. P. Garner
    S. Watts
    C. Parry
    J. Bird
    E. Kirkman
    World Journal of Surgery, 2009, 33 : 2194 - 2202
  • [38] Modeling and Model Predictive Control of Hemodynamic Variables during Hemodialysis
    Javed, Faizan
    Savkin, Andrey V.
    Chan, Gregory S. H.
    Mackie, James D.
    49TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2010, : 4673 - 4678
  • [39] Damage Control Resuscitation Supplemented with Vasopressin in a Severe Polytrauma Model with Traumatic Brain Injury and Uncontrolled Internal Hemorrhage
    Dickson, J. Michael
    Wang, Xu
    St John, Alexander E.
    Lim, Esther B.
    Stern, Susan A.
    White, Nathan J.
    MILITARY MEDICINE, 2018, 183 (9-10) : E460 - E466
  • [40] Impact of Controlled and Uncontrolled Hemorrhage (Two-Hit Model) and Resuscitation of OxyBridge and/or Plasma on Coagulopathy and Hemostasis in a Lethal Rat Model
    Song, Bjorn
    Nugent, William
    Light, Richard
    Vandegriff, Kim
    Light, William
    Benites, Andres
    Hack, Dallas
    ANESTHESIA AND ANALGESIA, 2024, 138 : 89 - 90