Comparative Study of Pulsed Versus Continuous High-Intensity Focused Ultrasound Ablation Using in vitro and in vivo Models

被引:7
|
作者
Wang, Yanhao [1 ,2 ]
Wang, Qi [1 ]
Luo, Yong [1 ]
Jiang, Lu [1 ]
Zeng, Zihuan [1 ]
Gan, Lidan [1 ]
Chen, Jianli [1 ]
Han, Hongfei [1 ]
Zou, Jianzhong [1 ]
机构
[1] Chongqing Med Univ, State Key Lab Ultrasound Engn Med Cofounded Chon, Chongqing Collaborat Innovat Ctr Minimally Invasi, Coll Biomed Engn, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Coll Stomatol, Chongqing 401147, Peoples R China
基金
美国国家科学基金会;
关键词
ablation; comparison; duty cycle; high-intensity focused ultrasound; identical doses; CAVITATIONAL ULTRASOUND; NONINVASIVE THERAPY; TISSUE; HIFU; EMBOLIZATION; FEASIBILITY; BACKSCATTER;
D O I
10.1002/jum.15098
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To compare the efficacy of pulsed high-intensity focused ultrasound (PHIFU) versus continuous high-intensity focused ultrasound (CHIFU) ablation at identical doses. Methods Continuous and pulsed HIFU (1200 J) at duty cycles (DCs) of 60% and 20% were examined for their capacity to ablate bovine liver tissue in vitro and rabbit liver tissue in vivo. After ablation, grayscale changes and pathologic characteristics were observed or measured, and the tissue necrosis volume, energy efficiency factor, and average grayscale density were calculated. Results The pulsed mode generated greater liquefaction necrosis. An inconspicuous grayscale change was observed for PHIFU at a DC of 20% in some samples, which appeared as an elliptical cavity. The energy efficiency factor of PHIFU at a DC of 60% was significantly lower than that of CHIFU, as observed both in vitro and in vivo (P < .05). The grayscale value and average grayscale density in response to CHIFU were significantly greater than those in response to PHIFU (60% or 20%; P < .05). Histopathologic analysis revealed liquefaction necrosis in all PHIFU groups. Conclusions At identical doses, compared with CHIFU, a single session of PHIFU can generate liquefaction necrosis and at a higher DC can improve ablation efficiency. This increased efficacy of PHIFU may involve enhancement of tissue destruction by cavitation effects and a reduction in the obstruction effect of endogenous microbubbles through cavitation effects or a more effective diffusion of heat.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 50 条
  • [1] In vitro and in vivo ablation of porcine renal tissues using high-intensity focused ultrasound
    Damianou, C
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09): : 1321 - 1330
  • [2] In vitro ablation of cardiac valves using high-intensity focused ultrasound
    Otsuka, R
    Fujikura, K
    Hirata, K
    Pulerwitz, T
    Oe, Y
    Suzuki, T
    Sciacca, R
    Marboe, C
    Wang, J
    Burkhoff, D
    Muratore, R
    Lizzi, FL
    Homma, S
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 109 - 114
  • [3] Experimental study in vivo ablation of swine pancreas using high-intensity focused ultrasound
    Huang, Guanghui
    Ye, Xin
    Yang, Xia
    Zheng, Aimin
    Li, Wenhong
    Wang, Jiao
    Han, Xiaoying
    Wei, Zhigang
    Meng, Min
    Ni, Yang
    Qin, Chengkun
    Fei, Xingbo
    Xiong, Liulin
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (02) : 286 - 290
  • [4] In Vitro Atrial Septal Ablation Using High-Intensity Focused Ultrasound
    Takei, Yasuyoshi
    Muratore, Robert
    Kalisz, Andrew
    Okajima, Kazue
    Fujimoto, Kohei
    Hasegawa, Takuya
    Arai, Kotaro
    Rekhtman, Yelena
    Berry, Grace
    Di Tullio, Marco R.
    Homma, Shunichi
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (04) : 467 - 472
  • [5] In Vitro and In Vivo High-Intensity Focused Ultrasound Thrombolysis
    Wright, Cameron
    Hynynen, Kullervo
    Goertz, David
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (04) : 217 - 225
  • [6] In Vitro and In Vivo Brain Ablation Created by High-Intensity Focused Ultrasound and Monitored by MRI
    Damianou, Christakis
    Ioannides, Kleanthis
    Hadjisavvas, Venos
    Mylonas, Nicos
    Couppis, Andreas
    Iosif, Demitris
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (06) : 1189 - 1198
  • [7] A Comparative Study of Fibroid Ablation Rates Using Radio Frequency or High-Intensity Focused Ultrasound
    Meng, Xin
    He, Guangbin
    Zhang, Jun
    Han, Zenghui
    Yu, Ming
    Zhang, Miaomiao
    Tang, Yu
    Fang, Ling
    Zhou, Xiaodong
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (04) : 794 - 799
  • [8] A Comparative Study of Fibroid Ablation Rates Using Radio Frequency or High-Intensity Focused Ultrasound
    Xin Meng
    Guangbin He
    Jun Zhang
    Zenghui Han
    Ming Yu
    Miaomiao Zhang
    Yu Tang
    Ling Fang
    Xiaodong Zhou
    [J]. CardioVascular and Interventional Radiology, 2010, 33 : 794 - 799
  • [9] High-intensity focused ultrasound ablation: an in vitro agarose gel model
    Yang, Sen
    Chen, Yi-Jing
    Cui, Ran
    Zhao, Hua-Xin
    Zhao, Yu
    Liu, Zhu-Qing
    Yu, Yi
    Shao, Xiao-Yan
    Xu, Qing
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (11): : 15302 - 15308
  • [10] Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model
    Frenkel, V
    Oberoi, J
    Stone, MJ
    Park, M
    Deng, C
    Wood, BJ
    Neeman, Z
    Horne, M
    Li, KCP
    [J]. RADIOLOGY, 2006, 239 (01) : 86 - 93