A device for 24 hour ambulatory monitoring of abdominal girth using inductive plethysmography

被引:22
|
作者
Reilly, BP
Bolton, MP
Lewis, MJ
Houghton, LA
Whorwell, PJ
机构
[1] Christie Hosp, Manchester M20 4BX, Lancs, England
[2] Univ S Manchester Hosp, Dept Med, Manchester M20 2LR, Lancs, England
关键词
IBS; irritable bowel syndrome; bloating; plethysmography;
D O I
10.1088/0967-3334/23/4/306
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Inductive plethysmography (IP) sensors and oscillator modules were assessed for their potential use in the ambulatory monitoring of abdominal girth in subjects with irritable bowel syndrome (IBS) in order to objectively quantify their bloating symptoms. A dedicated microprocessor data logger was designed to record over 24 h the frequency output of IP oscillators connected to a belt around the subject's lower abdomen. Posture was also recorded via tilt switches (standing, sitting and lying). The system was separately calibrated by placing the belts around a variable rectangular phantom and measuring the frequency of oscillation. A theoretical geometric model was devised to convert measured frequency into circumference and account for changes caused by variations in shape. Using the calibration factors, it was found that the circumference of a circular phantom could be measured accurately (mean difference 1.27 cm and SD 0.25 cm). The system has been tested over 24 h with 20 volunteers. Movement introduced variations in measured girth larger than those found during periods of non-movement during sleep. We conclude that IP promises to be a useful and quantitative tool suitable for ambulatory monitoring of abdominal girth, a hitherto relatively unexplored symptom of IBS.
引用
收藏
页码:661 / 670
页数:10
相关论文
共 50 条
  • [21] Ambulatory 24-hour Blood Pressure Monitoring (ABDM)
    Zweiker, R.
    JOURNAL FUR HYPERTONIE, 2012, 16 : 27 - 29
  • [22] AMBULATORY 24 HOUR ESOPHAGEAL PH MONITORING IN INFANTS AND CHILDREN
    CANNON, RA
    CLINICAL RESEARCH, 1984, 32 (01): : A96 - A96
  • [23] 24-Hour ambulatory blood pressure monitoring.
    O'Shea, J. Conor
    Calliff, Robert M.
    AMERICAN HEART JOURNAL, 2006, 151 (05) : 962 - 968
  • [24] 24-HOUR AMBULATORY ELECTROCARDIOGRAPHIC MONITORING ON A REGIONAL BASIS
    CADIGAN, PJ
    WILLIAMS, DO
    BRITISH MEDICAL JOURNAL, 1977, 2 (6084): : 439 - 440
  • [25] SYMPTOMS AND ARRHYTHMIAS DURING 24 HOUR AMBULATORY ELECTROCARDIOGRAPHIC MONITORING
    BLANCO, MV
    PINEIRO, DJ
    ROMANO, EA
    SUAREZ, LD
    MEDICINA-BUENOS AIRES, 1987, 47 (04) : 389 - 394
  • [26] 24 HOUR AMBULATORY INTRA-GASTRIC PH MONITORING
    KAPUR, BK
    BARDHAN, KD
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 736 - 737
  • [27] 24 HOUR INTERMITTENT, AMBULATORY BLOOD-PRESSURE MONITORING
    EGGER, M
    BIANCHETTI, MG
    GNADINGER, M
    KOBELT, R
    OETLIKER, O
    ARCHIVES OF DISEASE IN CHILDHOOD, 1987, 62 (11) : 1130 - 1135
  • [28] 24-HOUR AMBULATORY EEG MONITORING IN INFANTILE SPASMS
    PLOUIN, P
    DULAC, O
    JALIN, C
    CHIRON, C
    EPILEPSIA, 1993, 34 (04) : 686 - 691
  • [29] ONE-HOUR VERSUS 24-HOUR AMBULATORY ELECTROCARDIOGRAPHIC MONITORING - REPLY
    KENNEDY, HL
    SAYTHER, KL
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (05): : 1107 - 1108
  • [30] USING A NOVEL NON-INVASIVE, CUFF-LESS, WIRELESS DEVICE FOR 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING
    Gepner, Yftach
    Nachman, Dean
    Gilan, Adi
    Goldstein, Nir
    Constantini, Keren
    Littman, Romi
    Eisenkraft, Arik
    Grossman, Ehud
    JOURNAL OF HYPERTENSION, 2021, 39 : E135 - E135