The design and application of an in-laboratory diffraction-enhanced x-ray imaging instrument

被引:41
|
作者
Nesch, Ivan [1 ]
Fogarty, Daniel P. [1 ]
Tzvetkov, Tochko [1 ]
Reinhart, Benjamin [1 ]
Walus, A. Charles [1 ]
Khelashvili, Gocha [1 ,2 ]
Muehleman, Carol [3 ]
Chapman, Dean [4 ]
机构
[1] Nesch LLC, Crown Point, IN 46307 USA
[2] Rush Univ, Med Ctr, Dept Radiat Oncol, Chicago, IL 60612 USA
[3] Rush Med Coll, Dept Biochem, Chicago, IL 60612 USA
[4] Coll Med, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2009年 / 80卷 / 09期
关键词
MASS-DENSITY IMAGES; COMPUTED-TOMOGRAPHY; SYNCHROTRON-RADIATION; ARTICULAR-CARTILAGE; SOFT-TISSUE; RADIOGRAPHY; REFRACTION; BONE; CONTRAST; MODEL;
D O I
10.1063/1.3213621
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the design and application of a new in-laboratory diffraction-enhanced x-ray imaging (DEXI) instrument that uses a nonsynchrotron, conventional x-ray source to image the internal structure of an object. In the work presented here, a human cadaveric thumb is used as a test-sample to demonstrate the imaging capability of our instrument. A 22 keV monochromatic x-ray beam is prepared using a mismatched, two-crystal monochromator; a silicon analyzer crystal is placed in a parallel crystal geometry with the monochromator allowing both diffraction-enhanced imaging and multiple-imaging radiography to be performed. The DEXI instrument was found to have an experimentally determined spatial resolution of 160 +/- 7 mu m in the horizontal direction and 153 +/- 7 mu m in the vertical direction. As applied to biomedical imaging, the DEXI instrument can detect soft tissues, such as tendons and other connective tissues, that are normally difficult or impossible to image via conventional x-ray techniques. (C) 2009 American Institute of Physics. [doi:10.1063/1.3213621]
引用
收藏
页数:6
相关论文
共 50 条
  • [1] In-Laboratory Diffraction-Enhanced X-Ray Imaging of an Equine Hoof
    Fogarty, Daniel P.
    Reinhart, Benjamin
    Tzvetkov, Tochko
    Nesch, Ivan
    Williams, Cooper
    [J]. JOURNAL OF EQUINE VETERINARY SCIENCE, 2011, 31 (07) : 365 - 369
  • [2] In-Laboratory Diffraction-Enhanced X-ray Imaging for Articular Cartilage
    Muehleman, Carol
    Fogarty, Daniel
    Reinhart, Benjamin
    Tzvetkov, Tochko
    Li, Jun
    Nesch, Ivan
    [J]. CLINICAL ANATOMY, 2010, 23 (05) : 530 - 538
  • [3] X-ray diffraction-enhanced imaging (DEI)
    Lewis, RA
    Hall, CJ
    Hufton, AP
    Arfelli, F
    Evans, AJ
    Evans, SH
    [J]. RADIOLOGY, 2001, 221 : 165 - 165
  • [4] Diffraction-enhanced X-ray imaging of articular cartilage
    Mollenhauer, J
    Aurich, ME
    Zhong, Z
    Muehleman, C
    Cole, CC
    Hasnah, M
    Oltulu, O
    Kuettner, KE
    Margulis, A
    Chapman, LD
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (03) : 163 - 171
  • [5] X-ray diffraction-enhanced imaging of uterine leiomyomas
    Liu, CL
    Zhang, Y
    Zhang, XY
    Yang, WT
    Peng, WJ
    Shi, D
    Zhu, PP
    Tian, YL
    Huang, WX
    [J]. MEDICAL SCIENCE MONITOR, 2005, 11 (05): : MT33 - MT38
  • [6] Quantitative diffraction-enhanced x-ray imaging of weak objects
    Nesterets, YI
    Gureyev, TE
    Paganin, D
    Pavlov, KM
    Wilkins, SW
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2004, 37 (08) : 1262 - 1274
  • [7] High-Energy Diffraction-Enhanced X-ray Imaging
    Yoneyama, Akio
    Takeda, Tohoru
    Yamazaki, Takanori
    Hyodo, Kazuyuki
    Ueda, Kazuhiro
    [J]. SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 477 - +
  • [8] Diffraction-enhanced imaging with synchrotron radiation X-ray for liver
    Peng, Yi-Feng
    Chen, Shaoliang
    Tang, Guangyu
    Chen, Yuesheng
    Shen, Renjie
    Chenb, Aiping
    Zhu, Pei-Ping
    Huang, Wan-Xia
    Yuan, Qing-Xi
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2007, 15 (02) : 97 - 100
  • [9] Visualization of hydrides in titanium by means of diffraction-enhanced X-ray imaging
    Mizuno, K
    Kobayashi, T
    Fujiki, F
    Okamoto, H
    Furuya, Y
    Hirano, K
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2005, 402 (1-2) : 109 - 114
  • [10] Biological imaging by X-ray phase tomography using diffraction-enhanced imaging
    Koyama, I
    Momose, A
    Wu, J
    Lwin, TT
    Takeda, T
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (11): : 8219 - 8221