The Fugl-Meyer assessment of the upper extremity: reliability, responsiveness and validity of the Danish version

被引:103
|
作者
Lundquist, Camilla Biering [1 ]
Maribo, Thomas [2 ,3 ]
机构
[1] Hammel Neurorehabil Ctr, Dept Dev, Voldbyvej 15, Hammel, Denmark
[2] Aarhus Univ, Rehabil Ctr Marselisborg, Dept Publ Hlth, Sect Social Med & Rehabil, Aarhus, Denmark
[3] Publ Hlth & Qual Improvement Cent Denmark Reg, Aarhus, Denmark
关键词
Danish; Fugl-Meyer assessment upper extremity; outcome assessment; reliability; stroke; validity; MOTOR-ASSESSMENT SCALE; RESEARCH ARM TEST; CLINICALLY IMPORTANT DIFFERENCES; HEALTH-STATUS QUESTIONNAIRES; STROKE PATIENTS; INTERRATER RELIABILITY; IMPORTANT DIFFERENCE; CULTURAL-ADAPTATION; CONSTRUCT-VALIDITY; SUBACUTE STROKE;
D O I
10.3109/09638288.2016.1163422
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To translate the Fugl-Meyer Assessment of the Upper Extremity (FMA-UE) into Danish and to establish the inter-tester reliability, responsiveness, Minimal Clinically Important Difference (MCID) and concurrent validity of the FMA-UE in a population of stroke patients. Method: The translation was conducted in accordance with the principles outlined by the ISPOR Task Force for Translation and Cultural Adaption. Inter-rater reliability was assessed at baseline. Each patient was tested by two examiners and inter class correlation (ICC) was calculated. Responsiveness was assessed using receiver operating characteristic (ROC) curve statistics. The FMA-UE change score was used to assess sensitivity and specificity and to correctly determine which patients had improved. The MCID and the area under the curve (AUC) were established using the ROC. The FMA-UE's concurrent validity with the Motor Assessment Scale was determined using Spearman's rank correlation. Setting: The study took place at Skive Neurorehabilition, Denmark from May 2014 to February 2015. Participants: Inpatients, who were in the acute to sub-acute stage of stroke and aged >18 years. Interventions: Not applicable. Main outcome measure: The FMA-UE. Results: In 50 inpatients the ICC was 0.95, AUC was 0.87, with a sensitivity of 77%, a specificity of 89% and an MCID >= 4. Concurrent validity was high, with r = 0.94-0.95. Conclusion: The FMA-UE was successfully translated into Danish. An MCID >= 4 was found. This study provides evidence that the FMA-UE is a reliable, responsive and valid instrument for measuring upper limb impairment after stroke.
引用
收藏
页码:934 / 939
页数:6
相关论文
共 50 条
  • [21] RELIABILITY OF THE FUGL-MEYER ASSESSMENT OF SENSORIMOTOR RECOVERY FOLLOWING CEREBROVASCULAR ACCIDENT
    DUNCAN, PW
    PROPST, M
    NELSON, SG
    PHYSICAL THERAPY, 1983, 63 (10): : 1606 - 1610
  • [22] Cross-cultural translation and adaptation of the Danish version of the Fugl-Meyer assessment for post stroke sensorimotor function
    Busk, H.
    Murphy, M. Alt
    Korsman, R.
    Skou, S. T.
    Wienecke, T.
    DISABILITY AND REHABILITATION, 2022, 44 (17) : 4888 - 4895
  • [23] The clinical significance of Fugl-Meyer Test of Motor Function upper extremity scores.
    Richards, LG
    Duncan, P
    Perera, S
    Lai, S
    Zahner, L
    Van Culin, V
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2002, 50 (04) : S96 - S97
  • [24] Intra- and inter-rater reliability of Fugl-Meyer Assessment of Lower Extremity early after stroke
    Hernandez, Edgar D.
    Forero, Sandra M.
    Galeano, Claudia P.
    Barbosa, Nubia E.
    Sunnerhagen, Katharina S.
    Alt Murphy, Margit
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2021, 25 (06) : 709 - 718
  • [25] Estimating TheMinimally Clinically Important Difference of the Upper Extremity Scale of the Fugl-Meyer Assessment in Chronic, Severe Stroke
    Barden, Elliot
    Plow, Ela
    Knutson, Jayme
    Wang, Xiaofeng
    Perlic, Kaitlin
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2023, 77
  • [26] Item Difficulty of Fugl-Meyer Assessment for Upper Extremity in Persons With Chronic Stroke With Moderate-to-Severe Upper Limb Impairment
    Hijikata, Nanako
    Kawakami, Michiyuki
    Ishii, Ryota
    Tsuzuki, Keita
    Nakamura, Takuya
    Okuyama, Kohei
    Liu, Meigen
    FRONTIERS IN NEUROLOGY, 2020, 11
  • [27] Cellphone-Based Automated Fugl-Meyer Assessment to Evaluate Upper Extremity Motor Function After Stroke
    Song, Xinyu
    Chen, Shugeng
    Jia, Jie
    Shull, Peter B.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (10) : 2186 - 2195
  • [28] Evaluation of Upper-Limb Feeding Performance Using the Fugl-Meyer Assessment
    Sone, Toshimasa
    Iokawa, Kazuaki
    Hasegawa, Keiichi
    Tsukada, Tetsu
    Kaneda, Mariko
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2017, 71 (04):
  • [29] Development and feasibility of a modified Fugl-Meyer lower extremity assessment for telerehabilitation: a pilot study
    Peters, Sue
    Botero, Marcela
    Evers, Allison
    Fong, Brianna
    Jakab, Botond
    Petter, Emily
    Eng, Janice J.
    PILOT AND FEASIBILITY STUDIES, 2021, 7 (01)
  • [30] Development and feasibility of a modified Fugl-Meyer lower extremity assessment for telerehabilitation: a pilot study
    Sue Peters
    Marcela Botero
    Allison Evers
    Brianna Fong
    Botond Jakab
    Emily Petter
    Janice J. Eng
    Pilot and Feasibility Studies, 7