摘要
Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
引用
收藏
页码:331 / 362
页数:34
相关论文
共 50 条
  • [31] Fluid-structure interaction in bi-leaflet mechanical heart valves
    Borazjani, Iman
    Ge, Liang
    Sotiropoulos, Fotis
    Dasi, Lakshm Prasad
    Yogonathan, Ajit
    Proceedings of the 2nd Frontiers in Biomedical Devices Conference, 2007, : 17 - 18
  • [33] Whole-heart modelling with valves in a fluid-structure interaction framework
    Feng, Liuyang
    Gao, Hao
    Luo, Xiaoyu
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2024, 420
  • [34] 3D PIV measurements of prosthetic heart valves fluid dynamics
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 868 - 868
  • [35] In VitroCalcification of Bioprosthetic Heart Valves: Test Fluid Validation on Prosthetic Material Samples
    Kiesendahl, N.
    Schmitz, C.
    Menne, M.
    Schmitz-Rode, T.
    Steinseifer, U.
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (02) : 885 - 899
  • [36] THE CEREBROSPINAL FLUID VALVES
    WELCH, K
    FRIEDMAN, V
    BRAIN, 1960, 83 (03) : 454 - &
  • [37] Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves
    Johansen, Peter
    Engholt, Henrik
    Tang, Mariann
    Nybo, Rasmus F.
    Rasmussen, Per D.
    Nielsen-Kudsk, Jens Erik
    EUROINTERVENTION, 2017, 13 (09) : 1026 - 1031
  • [38] A model for mechanics of primary lymphatic valves
    Mendoza, E
    Schmid-Schönbein, GW
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 407 - 414
  • [39] Quantum Mechanics and Spin-Valves
    Prevenslik, Thomas
    2013 13TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2013, : 784 - 788
  • [40] Fluid mechanics and continuum mechanics
    O. Molerus
    Heat and Mass Transfer, 2008, 44 : 625 - 633