Design and off-design performance comparison of supercritical carbon dioxide Brayton cycles for particle-based high temperature concentrating solar power plants

被引:61
|
作者
Chen, Rui [1 ,2 ]
Romero, Manuel [2 ]
Gonzalez-Aguilar, Jose [2 ]
Rovense, Francesco [3 ]
Rao, Zhenghua [1 ,2 ]
Liao, Shengming [1 ]
机构
[1] Cent South Univ, Sch Energy & Engn, Changsha 410083, Hunan, Peoples R China
[2] IMDEA Energy, High Temp Proc Unit, Avda Ramon de La Sagra 3, Madrid 28935, Spain
[3] Univ Rey Juan Carlos, Madrid 28933, Spain
关键词
Concentrating solar power; Supercritical carbon dioxide; Brayton cycle; Off-design performance; Solar particle receiver; Dry cooling; OPTIMIZATION; INTEGRATION; SYSTEM; TOWERS;
D O I
10.1016/j.enconman.2021.113870
中图分类号
O414.1 [热力学];
学科分类号
摘要
Concentrated solar power (CSP) plants using dense particle suspension as heat transfer fluid and particles as the storage medium are considered as a promising solution to provide the high temperature required for the supercritical carbon dioxide (S-CO2) Brayton cycle. During plant operation, variations in the heat transfer fluid temperature and ambient temperature would significantly affect system performance. Determining the suitable S-CO2 Brayton cycle configuration for this particle-based CSP plant requires accurate prediction and comprehensive comparison on the system performance both at design and off-design conditions. This study presents a common methodology to homogeneously assess the plant performance for six 10 MW S-CO2 Brayton cycles (i.e. simple regeneration, recompression, precompression, intercooling, partial cooling and split expansion) integrated with a hot particles thermal energy storage and a dry cooling system. This methodology includes both design and off-design detailed models based on the characteristic curves of all components. The optimal design for each thermodynamic cycle has been determined under the same boundary design constrains by a genetic algorithm. Then, their off-design performances have been quantitatively compared under varying particle inlet temperature and ambient temperature, in terms of cycle efficiency, net power output and specific work. Results show that the variation in ambient temperature contributes to a greater influence on the cycle off-design performance than typical variations of the heat transfer fluid temperature. Cycles with higher complexity have larger performance deterioration when the ambient temperature increases, though they could present higher peak efficiency and specific work at design-point. In particular, the cycle with maximum efficiency or specific work presents significant changes in different ranges of ambient temperature. This means that for the selection of the best configuration, the typical off-design operation conditions should be considered as well. For integrating with high-temperature CSP plants and dry cooling systems, the simple regeneration and the recompression cycles are the most suitable S-CO2 Brayton cycle configurations due to their fewer performance degradations at ambient temperatures above 30 degrees C, which is a frequent environmental condition in sunny areas of the world.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Rapid Prediction and Optimization for Off-design Performance of Gas and Supercritical Carbon Dioxide Combined Cycle Based on Neural Network
    Cao, Yue
    Chen, Ranjing
    Zhan, Jun
    Chen, Yifan
    Si, Fengqi
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (11): : 4178 - 4189
  • [32] Capital Cost Assessment of Concentrated Solar Power Plants Based on Supercritical Carbon Dioxide Power Cycles
    Crespi, Francesco
    Sanchez, David
    Sanchez, Tomas
    Martinez, Gonzalo S.
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2019, 141 (07):
  • [33] Off-design and annual performance analysis of supercritical carbon dioxide cycle with thermal storage for CSP application
    Thanganadar, Dhinesh
    Fornarelli, Francesco
    Camporeale, Sergio
    Asfand, Faisal
    Patchigolla, Kumar
    [J]. APPLIED ENERGY, 2021, 282
  • [34] Optical and thermal integration analysis of supercritical CO2 Brayton cycles with a particle-based solar thermal plant based on annual performance
    Chen, Rui
    Romero, Manuel
    Gonzalez-Aguilar, Jose
    Rovense, Francesco
    Rao, Zhenghua
    Liao, Shengming
    [J]. RENEWABLE ENERGY, 2022, 189 : 164 - 179
  • [35] Off-Design Model of Concentrating Solar Power Plant with Thermochemical Energy Storage Based on Calcium-Looping
    Ortiz, Carlos
    Binotti, Marco
    Romano, Matteo C.
    Manuel Valverde, Jose
    Chacartegui, Ricardo
    [J]. SOLARPACES 2018: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2019, 2126
  • [36] One-Dimensional Optimization Design of Supercritical Carbon Dioxide Radial Inflow Turbine and Performance Analysis under Off-Design Conditions
    Tong, Zhiting
    Song, Zedong
    Zhang, Chao
    Xing, Hao
    Sun, Yuxuan
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [38] ANALYSES OF OFF-DESIGN POINT PERFORMANCES OF SIMPLE AND INTERCOOLED BRAYTON HELIUM RECUPERATED GAS TURBINE CYCLES FOR GENERATION IV NUCLEAR POWER PLANTS
    Gad-Briggs, Arnold
    Pilidis, Pericles
    [J]. PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 9, 2017,
  • [39] An operation strategy and off-design performance for supercritical brayton cycle using CO2-propane mixture in a direct-heated solar power tower plant
    Ma, Ning
    Bu, Zhengkun
    Fu, Yanan
    Hong, Wenpeng
    Li, Haoran
    Niu, Xiaojuan
    [J]. ENERGY, 2023, 278
  • [40] Research on the Performance of 1000MW Supercritical Carbon Dioxide Power Cycle Coal-fired Unit Under Off-design Conditions
    Chen, Jing
    Chen, Lei
    Zhou, Jing
    Zhu, Meng
    Liao, Haiyan
    Liu, Hui
    Xu, Kai
    Xiang, Jun
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (17): : 6681 - 6687