Discussion on alternative systems for film radiography

被引:0
|
作者
Vaessen, B [1 ]
Perdieus, P [1 ]
Willems, P [1 ]
机构
[1] KATHOLIEKE UNIV LEUVEN,DEPT MET,LOUVAIN,BELGIUM
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Film radiography is a well-established NDT technique and an accepted method for quality assurance. Recently, so-called new developments have been introduced to the market as alternatives for film radiography. Examples are fluorescent screen/film systems, cost containment films, wide-latitude films and storage phosphor plate systems. The authors have evaluated these systems and their applicability for NDT, taking into account factors such as sensitivity (image quality), speed handling, portability, reliability. In this paper the value and applicability for the NDT market of two of these methods, namely fluorescent screen systems and storage phosphor plates, are discussed, in comparison with conventional film techniques. Both technologies have been developed and are available within Agfa-Gevaert, therefore we can overview all aspects for the for Agfa strategic NDT market and discuss Agfa's strategy regarding these technologies; the conclusion is that all that is new is not necessarily beautiful!.
引用
收藏
页码:719 / 723
页数:5
相关论文
共 50 条
  • [21] Relative speeds of Kodak computed radiography phosphors and screen-film systems
    Department of Radiology, SUNY Hlth. Sci. Center at Syracuse, 750 East Adams Street, Syracuse, NY 13210, United States
    不详
    MED. PHYS., 10 (1621-1628):
  • [22] Relative speeds of Kodak computed radiography phosphors and screen-film systems
    Huda, W
    Rill, LN
    Bruner, AP
    MEDICAL PHYSICS, 1997, 24 (10) : 1621 - 1628
  • [23] Quality assurance in film radiography
    Insight Non Destr Test Cond Monit, 9 (698):
  • [24] POLAROID PHOTOGRAPHIC FILM IN RADIOGRAPHY
    HARTLEY, DE
    AUSTRALASIAN RADIOLOGY, 1966, 10 (03): : 251 - &
  • [25] Croatian film for industrial radiography
    Kauzlaric, L
    INSIGHT, 2000, 42 (03) : 192 - 192
  • [26] Croatian film for industrial radiography
    Kauzlaric, L., 2000, British Inst of Non-Destructive Testing, Northampton, United Kingdom (42):
  • [27] QUALITY ASSURANCE IN FILM RADIOGRAPHY
    VANBELLEGEM, L
    VAESSEN, B
    JANSSENS, J
    INSIGHT, 1995, 37 (09): : 698 - 699
  • [28] FILM QUALITY IN MAMMARY RADIOGRAPHY
    DEICHGRA.E
    REICHMAN.S
    BUREN, M
    ACTA RADIOLOGICA-DIAGNOSIS, 1974, 15 (01): : 93 - 103
  • [29] Estimation of of Exposure Time in Digital Radiography Applicable to Film Radiography
    Yang, Jin Wook
    Jeon, Seo Ung
    Cho, Kap Ho
    Nam, Mun Ho
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2021, 41 (05) : 289 - 296
  • [30] ALTERNATIVE SCANNING APPROACHES TO EQUALIZATION RADIOGRAPHY
    PLEWES, DB
    SHAW, CG
    MEDICAL PHYSICS, 1985, 12 (04) : 512 - 512