Evaluation of substitutes for bone: Comparison of microradiographic and histological assessments

被引:20
|
作者
Thorwarth, M.
Wehrhan, F.
Srour, S.
Schultze-Mosgau, S.
Felszeghy, E.
Bader, R. D.
Schlegel, K. A.
机构
[1] Univ Jena, Dept Oral & Maxillofacial Surg Plast Surg, D-07747 Jena, Germany
[2] Univ Erlangen Nurnberg, Dept Oral & Maxillofacial Surg, D-91054 Erlangen, Germany
[3] Semmelweis Univ, Inst Forens Med, HU-1091 Budapest, Hungary
来源
关键词
microradiographic evaluation; bone regeneration; anorganic bone matrix; phycogenic hydroxyapatite; chemically sterilised bone; animal model; prospective study;
D O I
10.1016/j.bjoms.2006.03.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
We created defects of standard size in the frontal bones of adult pigs and filled them with four different materials. On six occasions (at 1, 2, 4, 8, 12, and 26 weeks), samples were harvested, and evaluated by computing microradiographic images. We examined the specimens histologically as controls. After insertion of anorganic materials, microradiographic evaluation was easy and precise, and there were no significant differences between them and the histological controls (p = 0.2). A quantitative evaluation of chemically sterilised bone by computer was not possible for more than 4 weeks. (C) 2006 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [1] Microradiographic and histological evaluation of the bone-screw and bone-plate interface of orthodontic miniplates in patients
    Vandergugten, Simon
    Cornelis, Marie A.
    Mahy, Pierre
    Nyssen-Behets, Catherine
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (03) : 325 - 329
  • [2] HISTOLOGICAL AND MICRORADIOGRAPHIC EFFECTS OF MECHANICAL-STRESS ON BONE
    HINRICHSEN, G
    JOURNAL OF DENTAL RESEARCH, 1976, 55 : B104 - B104
  • [3] MICRORADIOGRAPHIC AND HISTOLOGICAL STUDY OF THE STYLOID PROCESS OF THE TEMPORAL BONE
    LENGELE, B
    DHEM, A
    ACTA ANATOMICA, 1989, 135 (03): : 193 - 199
  • [4] In vivo evaluation of resorbable bone graft substitutes in beagles: Histological properties
    Shih, Tsai-Chin
    Teng, Nai-Chia
    Wang, Peter-D.
    Lin, Che-Tong
    Yang, Jen-Chang
    Fong, Sheng-Wei
    Lin, Hsi-Kuei
    Chang, Wei-Jen
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2013, 101 (08) : 2405 - 2411
  • [5] COMPARISON OF MICRORADIOGRAPHIC AND HISTOLOGIC PATTERNS IN BONE
    COHEN, J
    LACROIX, P
    LABORATORY INVESTIGATION, 1953, 2 (06) : 447 - 450
  • [6] MICRORADIOGRAPHIC AND HISTOLOGICAL EXAMINATION OF SPLIT-LINE FORMATION IN BONE
    BUCKLANDWRIGHT, JC
    JOURNAL OF ANATOMY, 1977, 124 (SEP) : 193 - 203
  • [7] Physical and Histological Comparison of Hydroxyapatite, Carbonate Apatite, and -Tricalcium Phosphate Bone Substitutes
    Ishikawa, Kunio
    Miyamoto, Youji
    Tsuchiya, Akira
    Hayashi, Koichiro
    Tsuru, Kanji
    Ohe, Go
    MATERIALS, 2018, 11 (10)
  • [8] Orthodontic loading of titanium miniplates in dogs:: microradiographic and histological evaluation
    Cornelis, M. A.
    Vandergugten, S.
    Mahy, P.
    De Clerck, H. J.
    Lengele, B.
    D'Hoore, W.
    Nyssen-Behets, C.
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (10) : 1054 - 1062
  • [9] BONE RESORPTION IN CHRONIC RENAL-FAILURE - COMPARISON OF RADIOLOGICAL AND HISTOLOGICAL ASSESSMENTS
    DOYLE, FH
    WILLIAMS, ED
    SHACKMAN, R
    CARROLL, RNP
    AUNG, T
    BRITISH MEDICAL BULLETIN, 1972, 28 (03) : 225 - &
  • [10] Evaluation of bone graft substitutes
    Gouin, F