Diffusion-weighted magnetic resonance imaging for the assessment of liver fibrosis in chronic viral hepatitis

被引:14
|
作者
Charatcharoenwitthaya, Phunchai [1 ]
Sukonrut, Kamonthip [1 ]
Korpraphong, Pornpim [2 ]
Pongpaibul, Ananya [3 ]
Saiviroonporn, Pairash [2 ]
机构
[1] Mahidol Univ, Fac Med, Siriraj Hosp, Dept Med,Div Gastroenterol, Bangkok, Thailand
[2] Mahidol Univ, Fac Med, Siriraj Hosp, Radiol Dept, Bangkok, Thailand
[3] Mahidol Univ, Fac Med, Siriraj Hosp, Pathol Dept, Bangkok, Thailand
来源
PLOS ONE | 2021年 / 16卷 / 03期
关键词
D O I
10.1371/journal.pone.0248024
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Accurate noninvasive methods for the assessment of liver fibrosis are urgently needed. This prospective study evaluated the diagnostic accuracy of diffusion-weighted magnetic resonance imaging (DWI) for the staging of liver fibrosis and proposed a diagnostic algorithm using DWI to identify cirrhosis in patients with chronic viral hepatitis. Methods One hundred twenty-one treatment-naive patients with chronic hepatitis B or C were evaluated with DWI followed by liver biopsy on the same day. Breath-hold single-shot echo-planar DWI was performed to measure the apparent diffusion coefficient (ADC) of the liver and spleen. Normalized liver ADC was calculated as the ratio of liver ADC to spleen ADC. Results There was an inverse correlation between fibrosis stage and normalized liver ADC (p<0.05). For the prediction of fibrosis stage >= 2, stage >= 3, and cirrhosis, the area under the receiver-operating curve of normalized liver ADC was 0.603, 0.704, and 0.847, respectively. The normalized liver ADC value <= 1.02 x 10(-3) mm(2)/s had 88% sensitivity, 81% specificity, 25% positive predictive value (PPV), and 99% negative predictive value (NPV) for the diagnosis of cirrhosis. Using a sequential approach with the Fibrosis-4 index followed by DWI, normalized liver ADC <= 1.02 x 10(-3) mm(2)/s in patients with Fibrosis-4 > 3.25 yielded an 80% PPV for cirrhosis, and a 100% NPV to exclude cirrhosis in patients with Fibrosis-4 between 1.45 and 3.25. Only 15.7% of patients would require a liver biopsy. This sequential strategy can reduce DWI examinations by 53.7%. Conclusion Normalized liver ADC measurement on DWI is an accurate and noninvasive tool for the diagnosis of cirrhosis in patients with chronic viral hepatitis.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Diffusion kurtosis imaging and diffusion-weighted imaging in assessment of liver fibrosis stage and necroinflammatory activity
    Ruo Fan Sheng
    He Qing Wang
    Li Yang
    Kai Pu Jin
    Yan Hong Xie
    Cai Zhong Chen
    Meng Su Zeng
    Abdominal Radiology, 2017, 42 : 1176 - 1182
  • [22] Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver
    Thomas C. Kwee
    Taro Takahara
    Tetsu Niwa
    Marko K. Ivancevic
    Gwenael Herigault
    Marc Van Cauteren
    Peter R. Luijten
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2009, 22 : 319 - 325
  • [23] Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver
    Kwee, Thomas C.
    Takahara, Taro
    Niwa, Tetsu
    Ivancevic, Marko K.
    Herigault, Gwenael
    Van Cauteren, Marc
    Luijten, Peter R.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2009, 22 (05) : 319 - 325
  • [24] The Fontan circulation and the liver: A magnetic resonance diffusion-weighted imaging study
    Wolff, Djoeke
    van Melle, Joost P.
    Dijkstra, Hildebrand
    Bartelds, Beatrijs
    Willems, Tineke P.
    Hillege, Hans
    van den Berg, Aad P.
    Ebels, Tjark
    Sijens, Paul E.
    Berger, Rolf M. F.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 202 : 595 - 600
  • [25] Diffusion-Weighted Magnetic Resonance Imaging in Assessment of Primary Liver Cancer after HIFU Treatment
    Li, Sheng
    Shi, Sili
    Le, Aiping
    Liu, Huihui
    Cai, Lili
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (04): : 305 - 308
  • [26] Liver fibrosis detected by diffusion-weighted magnetic resonance imaging and its functional correlates in Fontan patients
    Lu, Chun-Wei
    Wu, Chih-Horng
    Huang, Miao-Tzu
    Lee, Chee-Seng
    Chen, Huey-Ling
    Lin, Ming-Tai
    Chiu, Shuenn-Nan
    Tseng, Wei-Chieh
    Chen, Chun-An
    Wang, Jou-Kou
    Wu, Mei-Hwan
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 66 (01)
  • [27] Diffusion-weighted magnetic resonance imaging for staging liver fibrosis is less reliable in the presence of fat and iron
    Robin Bülow
    Birger Mensel
    Peter Meffert
    Diego Hernando
    Matthias Evert
    Jens-Peter Kühn
    European Radiology, 2013, 23 : 1281 - 1287
  • [28] Diffusion-weighted magnetic resonance imaging for staging liver fibrosis is less reliable in the presence of fat and iron
    Buelow, Robin
    Mensel, Birger
    Meffert, Peter
    Hernando, Diego
    Evert, Matthias
    Kuehn, Jens-Peter
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1281 - 1287
  • [29] Breast Magnetic Resonance Imaging: Diffusion-Weighted Imaging
    Brandao, Alice C.
    Lehman, Constance D.
    Partridge, Savannah C.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2013, 21 (02) : 321 - +
  • [30] Diffusion-weighted magnetic resonance imaging of the abdomen
    Schmid-Tannwald, C.