Potential for Peak Flow Reduction by Rainwater Harvesting Tanks

被引:15
|
作者
Campisano, A. [1 ]
Di Liberto, D. [1 ]
Modica, C. [1 ]
Reitano, S. [2 ]
机构
[1] Univ Catania, Dept Civil Engn & Architecture, Vle A Doria 6, I-95125 Catania, Italy
[2] Kore Univ Enna, Fac Engn & Architecture, I-94100 Enna, Italy
关键词
Rainwater harvesting; rainwater tanks; peak flow reduction; WATER;
D O I
10.1016/j.proeng.2014.11.441
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of the paper is to evaluate the potential of tank-based rainwater harvesting systems as source control methods to mitigate runoff flow peaks in urban areas. Water balance simulations of the rainwater tanks at the resolution time scale of 1 minute were carried out for this purpose using both high-resolution rainfall series and toilet water demand data from a previous experimental campaign, which involved six experimental households in southern Italy. Simulations show that significant reduction of the flow peak may be obtained with rainwater tanks depending on the tank size and on the household water demand. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1507 / 1514
页数:8
相关论文
共 50 条
  • [31] RAINWATER HARVESTING POTENTIAL IN MAHASARAKHAM UNIVERSITY (KHAMRIANG CAMPUS)
    Chaimoon, Nida
    [J]. ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 781 - 782
  • [32] Potential of peak flood flow reduction by small retarding basins
    Von Ley, Rita
    Casper, Markus
    Kreiter, Thomas
    [J]. WasserWirtschaft, 2007, 97 (06) : 10 - 15
  • [33] Rainwater harvesting
    Vishwanath, S
    [J]. JOURNAL OF THE GEOLOGICAL SOCIETY OF INDIA, 2001, 57 (05) : 472 - 472
  • [34] Rainwater Harvesting System Integrated With Sensors for Attic Temperature Reduction
    Yew, Ming Chian
    Wong, Song Wei
    Yew, Ming Kun
    Saw, Lip Huat
    [J]. FRONTIERS IN BUILT ENVIRONMENT, 2021, 7
  • [35] Investment Evaluation of Rainwater Tanks
    Khastagir, Anirban
    Jayasuriya, Niranjali
    [J]. WATER RESOURCES MANAGEMENT, 2011, 25 (14) : 3769 - 3784
  • [36] Investment Evaluation of Rainwater Tanks
    Anirban Khastagir
    Niranjali Jayasuriya
    [J]. Water Resources Management, 2011, 25 : 3769 - 3784
  • [37] PEAK POTENTIAL OF A PROBE IN OIL TANKS DURING PUMPING
    TOTTORI, K
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 1966, 86 (08) : 1 - &
  • [38] Influence of the Temporal and Spatial Variability of Rainfall on the Sizing of Tanks for Rainwater Harvesting in Brazil: A Multivariate Analysis
    Pâmela Rafanele França Pinto
    Michael Silveira Thebaldi
    Marina Neves Merlo
    Junio Aparecido Pereira Corrêa
    Mateus Alexandre da Silva
    [J]. International Journal of Civil Engineering, 2023, 21 : 409 - 425
  • [39] Probabilistic modeling of rainwater tanks
    Raimondi, A.
    Becciu, G.
    [J]. 16TH WATER DISTRIBUTION SYSTEM ANALYSIS CONFERENCE (WDSA2014): URBAN WATER HYDROINFORMATICS AND STRATEGIC PLANNING, 2014, 89 : 1493 - 1499
  • [40] The effect of number of tanks on water quality in rainwater harvesting systems under sudden contaminant input
    Dissanayake, Janith
    Han, Mooyoung