Progress is being made in the development of an Ion Source Test Facility (ISTF) by D-Pace Inc. in collaboration with Buckley Systems Ltd. in Auckland, NZ. The first phase of the ISTF is to be commissioned in October 2015 with the second phase being commissioned in March 2016. The facility will primarily be used for the development and the commercialization of ion sources. It will also be used to characterize and further develop various D-Pace Inc. beam diagnostic devices. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Experimental and simulation study on the backstreaming positive ions on the quarter-size negative ion source for CRAFT NNBI test facility
    Xu, Yongjian
    Yang, Yuwen
    Wei, Jianglong
    Yu, Ling
    Deng, Wen
    Wang, Rixin
    Gu, Yuming
    Hu, Chundong
    Xie, Yahong
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (02) : 546 - 551
  • [22] SINGLE-CRATE STAND-ALONE CAMAC CONTROL-SYSTEM FOR A NEGATIVE-ION SOURCE TEST FACILITY
    JURAS, RC
    ZIEGLER, NF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (03) : 3442 - 3444
  • [23] Suppression of stray electrons in the negative ion accelerator of CRAFT NNBI test facility
    Yang, Yuwen
    Wei, Jianglong
    Xie, Junwei
    Gu, Yuming
    Xie, Yahong
    Hu, Chundong
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (03) : 939 - 946
  • [24] Numerical simulations of the first operational conditions of the negative ion test facility SPIDER
    Serianni, G.
    Agostinetti, P.
    Antoni, V.
    Baltador, C.
    Cavenago, M.
    Chitarin, G.
    Marconato, N.
    Pasqualotto, R.
    Sartori, E.
    Toigo, V.
    Veltri, P.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [25] An ion source research facility
    Roeder, M.
    Dehnel, M.
    Jackle, P.
    Stewart, T.
    Theroux, J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [26] TEST OF A RECOIL ION-SOURCE AT GANIL MEDIUM-ENERGY FACILITY
    GOSSELIN, A
    BODUCH, P
    HENNECART, D
    HICHAM, S
    HUSSON, X
    LECLER, D
    LEPOUTRE, A
    CASSIMI, A
    GRANDIN, JP
    [J]. JOURNAL DE PHYSIQUE III, 1994, 4 (09): : 1765 - 1777
  • [27] The status of the SNS external antenna ion source and spare RFQ test facility
    Welton, R. F.
    Aleksandrov, A. V.
    Dudnikov, V. G.
    Han, B. X.
    Kang, Y.
    Murray, S. N.
    Pennisi, T. R.
    Piller, C.
    Santana, M.
    Stockli, M. P.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [28] NEGATIVE ION SOURCE
    FOGEL, YM
    KOVAL, AG
    TIMOFEEV, AD
    [J]. SOVIET PHYSICS-TECHNICAL PHYSICS, 1960, 4 (11): : 1270 - 1277
  • [29] Development of a Utility Negative Ion Test Equipment With RF Source at ASIPP
    Wei, Jianglong
    Hu, Chundong
    Xie, Yahong
    Jiang, Caichao
    Liang, Lizhen
    Wang, Yan
    Gu, Yuming
    Yan, Jingyang
    Xu, Yongjian
    Xie, Yuanlai
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (05) : 1149 - 1155
  • [30] Development and test of 2.45 GHz microwave ion source based intense ion beam experimental facility
    Kumar, Narender
    Rodrigues, G.
    Mathur, Y.
    Ojha, S.
    Ahuja, R.
    Kanjilal, D.
    [J]. VACUUM, 2016, 124 : 55 - 59