A LOW COST AUTOSAMPLER FOR FLOW INJECTION ANALYSIS.

被引:21
|
作者
Kamogawa, Marcos Y. [1 ]
Teixeira, Marcelo Alves [2 ]
机构
[1] Univ Sao Paulo, Escola Super Agr Luiz de Queiroz, Dept Ciencias Exatas, BR-13418900 Piracicaba, SP, Brazil
[2] Univ Estadual Mato Grosso do Sul, BR-79830000 Dourados, MS, Brazil
来源
QUIMICA NOVA | 2009年 / 32卷 / 06期
关键词
ammonium; parallel ports; step motors;
D O I
10.1590/S0100-40422009000600048
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A LOW COST AUTOSAMPLER FOR FLOW INJECTION ANALYSIS. This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (51/4-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.
引用
收藏
页码:1644 / 1646
页数:3
相关论文
共 50 条
  • [21] Characterization and optimization of low cost microfluidic thread based electroanalytical device for micro flow injection analysis
    Agustini, Deonir
    Bergamini, Marcio F.
    Marcolino-Junior, Luiz Humberto
    [J]. ANALYTICA CHIMICA ACTA, 2017, 951 : 108 - 115
  • [22] DEVELOPMENT OF A FLOW INJECTION ANALYSIS SYSTEM EMPLOYNG ALTERNATIVE AND LOW-COST MATERIALS FOR DIDACTIC PURPOSES
    Moreira, Bruna C. S.
    Takeuchi, Regina M.
    Richter, Eduardo M.
    Santos, Andre L.
    [J]. QUIMICA NOVA, 2014, 37 (09): : 1566 - 1572
  • [23] Flow-through polarographic cell for flow-injection analysis. Determination of nifedipine in pharmaceutical formulations
    Richter, P
    Toral, MI
    Quiroz, G
    Jaque, P
    [J]. LABORATORY ROBOTICS AND AUTOMATION, 1997, 9 (05) : 255 - 262
  • [24] A simple, effective and low-cost extraction method for environmental soil analysis.
    Huang, TC
    Shan, YG
    Kupferle, M
    Zhou, Q
    Zhu, HJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 120 - ENVR
  • [25] Monitoring the enzymatic demethoxylation of fruit pectins by gas chromatography and flow-injection analysis.
    Maghasi, AT
    Berglund, KA
    Claus, MJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U30 - U30
  • [26] Selective determination of protolytes by flow injection analysis. A guide for the rational selection of reagent composition
    Albertus, F
    Cortes, I
    Danielsson, LG
    Ingman, F
    [J]. ANALYTICA CHIMICA ACTA, 1997, 344 (03) : 271 - 280
  • [27] On line determination of sulfate in extracted phosphoric acid using enthalpimetric flow injection analysis.
    Zhang, QY
    Wu, MQ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U126 - U126
  • [28] INTERACTIVE GAS FLOW ANALYSIS.
    Aylmer, Steven
    Brameller, Alfred
    [J]. Gas engineering and management, 1981, 21 (03): : 87 - 93
  • [29] New method for the flow analysis.
    Borghini, N
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U35 - U35
  • [30] Solar Pond Design and Cost Analysis.
    Latini, Giovanni
    Pacetti, Marco
    Principi, Paolo
    Sabetta, Filippo
    Testa, Fabiola
    [J]. 1600, (37):