Raman spectroscopy of coated pharmaceutical tablets and physical models for multivariate calibration to tablet coating thickness

被引:51
|
作者
Kauffman, John F.
Dellibovi, Marybeth
Cunningham, Charles R.
机构
[1] US FDA, Ctr Drug Evaluat & Res, Div Pharmaceut Anal, St Louis, MO 63101 USA
[2] Colorcon, Pharmaceut Tech Serv, West Point, PA 19486 USA
关键词
tablet coating analysis; Raman spectroscopy; multivariate calibration; chemometrics; target factor analysis;
D O I
10.1016/j.jpba.2006.06.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Raman spectra of a set of coated pharmaceutical tablets were analyzed for the purpose of calibrating the spectra to tablet coating thickness. Acetaminophen tablets were coated with a hydroxypropylmethylcellulose/polyethylene glycol film coating whose thickness was varied from 0 to 6% weight gain. Coatings were also prepared with two concentrations of TiO2 at several film thicknesses. The resulting spectral data set was analyzed using several different multivariate calibration procedures. The procedures examined in this study included spectral correction followed by target factor analysis, spectral correction with baseline subtraction followed by principal component regression, and first derivative computation followed by principal component regression. The results demonstrate that target factor analysis is a viable method for calibration of Raman spectra to tablet coating thickness. Calibration based on derivative spectra resulted in linear correlation that was equal to that of the results of target factor analysis for coatings without TiO2. However, target factor analysis was found to be superior to other methods when TiO2 was present in the tablet coatings. The effect of sample fluorescence on each of these chemometric methods was also examined. It was found that when photobleaching of fluorescent impurities due to exposure to the Raman excitation source was controlled, the tablet coating thickness could be calibrated to the intensity of the fluorescence signal. The results also demonstrate that for the samples examined here, calibration by target factor analysis is insensitive to variation in fluorescent intensity when the tablet coating emission spectrum is included in the matrix of target vectors. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 50 条
  • [31] Thickness Measurement of Tablet Coating using Continuous Wave Terahertz Reflection Spectroscopy
    Devi, Nirmala
    Dash, Jyotirmayee
    Ray, Shaumik
    Pesala, Bala
    TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS IX, 2016, 9747
  • [32] SEM/EDX and Raman chemical imaging of pharmaceutical tablets: A comparison of tablet surface preparation and analysis methods
    Gupta, Shashwat
    Omar, Thamer
    Muzzio, Fernando J.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 611
  • [33] In-Line Monitoring of Coating Thickness of Pharmaceutical Tablets during Production Scale Film Coating by Terahertz Imaging
    May, Robert K.
    Evans, Michael J.
    Zhong, Shuncong
    Warr, Ian
    Gladden, Lynn F.
    Shen, Yaochun
    Zeitler, J. Axel
    35TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ 2010), 2010,
  • [34] Prediction of Tablet Film-coating Thickness Using a Rotating Plate Coating System and NIR Spectroscopy
    Romer, Meike
    Heinamaki, Jyrki
    Strachan, Clare
    Sandler, Niklas
    Yliruusi, Jouko
    AAPS PHARMSCITECH, 2008, 9 (04) : 1047 - 1053
  • [35] Prediction of Tablet Film-coating Thickness Using a Rotating Plate Coating System and NIR Spectroscopy
    Meike Römer
    Jyrki Heinämäki
    Clare Strachan
    Niklas Sandler
    Jouko Yliruusi
    AAPS PharmSciTech, 2008, 9 : 1047 - 1053
  • [36] Analysis of Pharmaceutical Tablet Coating Uniformity by Laser-Induced Breakdown Spectroscopy (LIBS)
    Atul Dubey
    Golshid Keyvan
    Richard Hsia
    Kostas Saranteas
    Dean Brone
    Tushar Misra
    Fernando J. Muzzio
    Journal of Pharmaceutical Innovation, 2011, 6 : 77 - 87
  • [37] Analysis of Pharmaceutical Tablet Coating Uniformity by Laser-Induced Breakdown Spectroscopy (LIBS)
    Dubey, Atul
    Keyvan, Golshid
    Hsia, Richard
    Saranteas, Kostas
    Brone, Dean
    Misra, Tushar
    Muzzio, Fernando J.
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2011, 6 (02) : 77 - 87
  • [38] Multivariate calibration techniques applied to derivative spectroscopy data for the analysis of pharmaceutical mixtures
    De Luca, Michele
    Oliverio, Filomena
    Ioele, Giuseppina
    Ragno, Gaetano
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2009, 96 (01) : 14 - 21
  • [39] Comparison of multivariate methods for quantitative determination with transmission Raman spectroscopy in pharmaceutical formulations
    Fransson, Magnus
    Johansson, Jonas
    Sparen, Anders
    Svensson, Olof
    JOURNAL OF CHEMOMETRICS, 2010, 24 (11-12) : 674 - 680
  • [40] Transmission Low-Frequency Raman Spectroscopy for Quantification of Crystalline Polymorphs in Pharmaceutical Tablets
    Inoue, Motoki
    Hisada, Hiroshi
    Koide, Tatsuo
    Fukami, Toshiro
    Roy, Anjan
    Carriere, James
    Heyler, Randy
    ANALYTICAL CHEMISTRY, 2019, 91 (03) : 1997 - 2003