A new dodecylsulfate ion-selective sensor based on electrochemically prepared polypyrrole and PVC

被引:0
|
作者
Alizadeh, N [1 ]
Mahmodian, M [1 ]
机构
[1] Tarbiat Modarres Univ, Dept Chem, Tehran, Iran
关键词
dodecylsulfate; sensor; ion-selective electrode; polypyrrole; electrochemical polymerization;
D O I
10.1002/(SICI)1521-4109(200005)12:7<509::AID-ELAN509>3.0.CO;2-U
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dodecylsulfate-doped polypyrrole (PPy-DS) was prepared electrochemically by anodic polymerization of pyrrole in the presence of dodecylsulfate (DS-) ions in aqueous solution and used as a DS- sensor. The effect of polymerization conditions on the characteristics of the potential response of the sensor was also investigated. The electrode made with PVC-PPy-DS membrane, plasticized with 2-nitro-phenyloctylether (o-NPOE) showed the Nernstian behavior (57.5 mV per decade over 10(-5) to 7 x 10(-3) M DS-) with a detection limit of 5 x 10(-6) M. The response time of the electrode is in the order of a few seconds and can be used for at least six months without any divergence. The electrode is highly selective to DS- ion over diverse inorganic anions.
引用
收藏
页码:509 / 512
页数:4
相关论文
共 50 条
  • [1] Linear alkylbenzenesulfonate (LAS) ion-selective electrode based on electrochemically prepared polypyrrole and PVC
    Alizadeh, N
    Khodaei-Tazekendi, H
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (1-2) : 5 - 10
  • [2] Nitrate ion-selective sensor based on electrochemically prepared conducting polypyrrole films
    Sun, BT
    Fitch, PG
    [J]. ELECTROANALYSIS, 1997, 9 (06) : 494 - 497
  • [3] PVC membrane cesium ion-selective sensor based on cephalexin antibiotic
    Saleh, MB
    Hassan, SSM
    Gaber, AAA
    Kream, NAA
    [J]. ANALYTICAL LETTERS, 2003, 36 (11) : 2367 - 2377
  • [4] Novel PVC membrane uranyl ion-selective sensor
    Saleh, MB
    Soliman, EM
    Gaber, AAA
    Ahmed, SA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 199 - 205
  • [5] ELECTROCHEMICALLY PREPARED CHALCOGENIDE ION-SELECTIVE MEMBRANES AS AN ALTERNATIVE TO CONVENTIONAL PRESSED-PELLET ION-SELECTIVE ELECTRODES
    NESHKOVA, MT
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 255 - 265
  • [6] Electrochemically driven ion-selective sensing and extraction based on PVC membrane coated electrodes.
    Weber, SG
    Sun, LF
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 371 - PMSE
  • [7] Electrochemically prepared chalcogenide-based membranes - A new generation of ion-selective flow-injection sensors
    Neshkova, M
    [J]. Sensors for Environmental Control, 2003, : 51 - 57
  • [8] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [9] Potentiometric determination of pantoprazole using an ion-selective sensor based on polypyrrole doped films
    Noronha, Barbara V.
    Bindewald, Eduardo H.
    de Oliveira, Michelle C.
    Papi, Mauricio A. P.
    Bergamini, Marcio F.
    Marcolino-, Luiz H., Jr.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 43 : 517 - 520
  • [10] ION-SELECTIVE ELECTRODES IN PVC MATRIX
    MIKHELSON, KN
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 18 (1-3) : 31 - 37