Suppression of primary chromatic aberration by genetic algorithm in an advanced telephoto lens

被引:5
|
作者
Tsai, Chen-Mu [1 ]
Fang, Yi-Chin [2 ]
Pai, Yang-Chieh [3 ]
机构
[1] Kun Shan Univ, Dept Comp & Commun, Yung Kang 710, Tainan Hsien, Taiwan
[2] Natl Kaohsiung First Univ Sci & Technol, Coll Engn, Dept Mech & Automat Engn, Kaohsiung 811, Taiwan
[3] Natl Cheng Kung Univ, Inst Electroopt Sci & Engn, Tainan 701, Taiwan
来源
OPTIK | 2009年 / 120卷 / 15期
关键词
Achromatic; Genetic algorithm (GA); Damped least squares (DLS); Optical design; Ray tracing; DESIGN; OPTIMIZATION;
D O I
10.1016/j.ijleo.2008.03.014
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper proposes a new method for finding a suitable glass combination set for an advanced telephoto lens via a genetic algorithm (GA). Normally, glass properties, inclusive of index and Abbe number, play a significant role in the elimination of primary chromatic aberration. So many optical glasses (over 300 different refractive types) have been developed hitherto that it is difficult to choose a state-of-the-art glass combination quickly. According to the newly developed GA operations in this paper, however, several suitable glass combinations can be found quickly through a unique sequence of function selection, crossover and mutation. An advanced telephoto lens design is employed in this research, which has the characteristic of being more sensitive to axial aberrations than lateral chromatic aberrations. The GA operations are described in the macro of the optical software program, CODE V. The simulation results in this research show that the primary chromatic aberration is efficiently eliminated after the application of GA. The main goal of this research is that during optimization, error function could be minimized only if primary aberrations are well under control in our first step; in a telephoto lens, the secondary spectrum of longitudinal chromatic aberration and lateral chromatic aberration caused by distortion play a role in chromatic aberration control as well; however, optimization with a combination of both primary chromatic aberration and secondary chromatic aberration will complicate the process with a lot of working variables. The GA method introduced in this paper might efficiently eliminate the primary chromatic aberration first by finding the best glass combination and its trend and then simplifying the following optimization process for all optical systems. Crown Copyright (C) 2008 Published by Elsevier GmbH. All rights reserved.
引用
收藏
页码:788 / 796
页数:9
相关论文
共 50 条
  • [31] Chromatic aberration in intraocular lens technologies to extend depth of focus
    Del Aguila-Carrasco, Antonio
    Weeber, Henk A.
    Alarcon, Aixa
    Piers, Patricia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [33] Design of a Lens System Reduces Chromatic Aberration for Proton Radiography
    Jia, Qinggang
    Wang, Wenyuan
    Xu, Haibo
    Lu, Liang
    LASER AND PARTICLE BEAMS, 2022, 2022
  • [34] Chromatic aberration of the human eye and corneal and crystalline lens powers
    Nakajima, Masashi
    Hiraoka, Takahiro
    Oshika, Tetsuro
    Hirohara, Yoko
    Mihashi, Toshifumi
    I-PERCEPTION, 2014, 5 (04): : 365 - 365
  • [35] A method of holographic chromatic aberration compensation based on a liquid lens
    School of Electronics and Information Engineering, Sichuan University, Chengdu
    Sichuan
    610065, China
    Zhongguo Jiguang, 5
  • [36] NEW CHROMATIC ABERRATION COEFFICIENT MEASUREMENT WITH A MAGNETIC ELECTRONIC LENS
    PERRIER, F
    TRINQUIE.J
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1968, 266 (17): : 1102 - &
  • [37] Zoom lens aberration correction algorithm
    Salter, N
    ZOOM LENSES III, 2001, 4487 : 76 - 82
  • [38] ON THE PRIMARY CHROMATIC COEFFICIENTS OF A LENS SYSTEM
    CRUICKSHANK, FD
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1946, 36 (02) : 103 - 107
  • [39] A Cost-Effective Triplet Lens Design with Chromatic Aberration Correction Based on Optimization Algorithm and Illustration Method
    Sun, Wen-Shing
    Tien, Chuen-Lin
    Liang, Siao-Suang
    Lin, Jhe-Syuan
    APPLIED SCIENCES-BASEL, 2022, 12 (23):
  • [40] Abbe numbers and chromatic aberration of a large group of intraocular lens designs
    Weeber, Henk A.
    Chang, Daniel H.
    Van der Mooren, Marrie
    Lowery, Mike
    Graver, Jacolien
    Piers, Patricia A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)