An Accurate Image Analysis Method for Estimating Body Measurements in Horses

被引:7
|
作者
Freitag, Giovanna Polo [1 ,2 ]
de Lima, Luis Gustavo Freitag
Jacomini, Julia Aparecida [1 ]
Kozicki, Luiz Ernandes [2 ]
Ribeiro, Leonir Bueno [1 ]
机构
[1] Univ Estadual Maringa, Dept Anim Sci, BR-87020900 Maringa, Parana, Brazil
[2] Pontifical Catholic Univ, Dept Agr Sci & Vet Med, Curitiba, Parana, Brazil
关键词
Biometrics; Equine; Conformation; Morphological features; EQUINE CONFORMATION; PERFORMANCE; TRAITS; COHORT;
D O I
10.1016/j.jevs.2021.103418
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This study proposes a standardized image analysis method for assessing horse conformation. A total of 34 adult American Quarter Horses (mean age = 6.7 +/- 2.9 years, body weight = 489 +/- 44 kg) were used. Reference angular measurements were performed using a digital goniometer, and reference linear measurements were determined using a standard measuring tape. For image analysis, photographs from the animal's left profile were taken at a distance of 3 m using eight markers to facilitate visualization. Images were processed using ImageJ software. Reference and estimated values showed great accuracy, with v 2 < 1%, Pearson's correlation coefficient > 0.999 ( P < . 001), and coefficient of variation < 2.70. Image analysis and reference results were similar ( P > . 05) for most variables. The highest coefficient of variation (3.05%) was observed for coxae-femur angle, where the software obtained an underestimation of 2.8 degrees compared with the reference method. Body length resulted in an overestimation of 3.4 cm in relation to reference values, but coefficient of variation was low (1.54%). Discrepancies between estimated and reference results can be attributed to possible errors when collecting biometric data using portable measuring tools, angles and long measurements being more difficult to obtain. Software analysis of standardized horse photographs is an accurate and precise method for obtaining body measurements and is therefore recommended for future studies on horse conformation. (c) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] AN IMPLANTABLE TELEMETRY UNIT FOR ACCURATE BODY TEMPERATURE MEASUREMENTS
    EPSTEIN, RJ
    HAUMANN, JR
    KEENER, RB
    JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (03) : 439 - &
  • [32] A Simplified Method For Estimating Body Volume In Men And Women Using Digital Image Plethysmography (DiP)
    Moon, Jordan R.
    Tobkin, Sarah E.
    Walter, Ashley A.
    Smith, Abbie E.
    Beck, Travis W.
    Cramer, Joel T.
    Stout, Jeffrey R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S270 - S271
  • [33] A SHORT ACCURATE METHOD FOR ESTIMATING THE VOLUME OF STREAM FLOW
    ROBINS, CR
    CRAWFORD, RW
    JOURNAL OF WILDLIFE MANAGEMENT, 1954, 18 (03): : 366 - 369
  • [34] A simple and accurate method for estimating bilirubin from blood
    Philips Research Asia-Bangalore, Nagawara, Bangalore 560045, India
    Conf. Rec. IEEE Instrum. Meas. Technol. Conf., 2011, (1442-1445):
  • [35] An accurate method of estimating pus and blood cells in urine
    Ockerblad, NF
    JOURNAL OF UROLOGY, 1928, 19 (04): : 525 - 526
  • [36] A simple, accurate method of estimating carbon monoxide in blood
    Roughton, FJW
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1941, 137 (02) : 617 - 625
  • [37] A Simple and accurate method for estimating bilirubin from blood
    Kudavelly, Srinivas
    Keswarpu, Payal
    Balakrishnan, S.
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 1442 - 1445
  • [38] ESTIMATING THE WEIGHT OF POLAR BEARS FROM BODY MEASUREMENTS
    KOLENOSKY, GB
    LUNN, NJ
    GREENWOOD, CJ
    ABRAHAM, KF
    JOURNAL OF WILDLIFE MANAGEMENT, 1989, 53 (01): : 188 - 190
  • [39] Development and application of "The Two Image" method for accurate object recognition and color analysis
    Alcicek, Zayde
    Balaban, Murat Omer
    JOURNAL OF FOOD ENGINEERING, 2012, 111 (01) : 46 - 51
  • [40] Digital image analysis; a novel and accurate method of monitoring foot ulcer healing
    Rajbhandari, SM
    Harris, ND
    Sutton, M
    Lockett, C
    Eaton, S
    Godour, M
    Tesfaye, S
    Ward, JD
    DIABETES, 1998, 47 : A167 - A167