Rationale and Objectives. The authors assessed and compared the performance of a computer-aided detection (CAD) scheme for the detection of masses and microcalcification clusters on a set of images collected from two consecutive ("current" and "prior") mammographic examinations. Materials and Methods. A previously developed CAD scheme was used to assess two consecutive screening mammograms from 200 cases in which the current mammogram showed a mass or cluster of microcalcifications that resulted in breast biopsy. The latest prior examinations had been initially interpreted as negative or definitely benign findings (Breast Imaging Reporting and Data System rating, 1 or 2). The study involved images of 400 examinations acquired in 200 patients. Radiologists identified 172 masses and 128 clusters of microcalcifications on the current images. The performance of the CAD scheme was analyzed and compared for the current and latest prior images. Results. There were significant differences (P < .01) between current and prior images in many feature values. The performance of the CAD scheme was significantly lower for prior than for current images (P < .01). At 0.5 and 0.2 false-positive mass and cluster cues per image, the scheme detected 78 malignant masses (78%) and 63 malignant clusters (80%) on current images. Only 42% of malignant cases were detected on prior images, including 40 masses (40%) and 36 microcalcification clusters (46%). Conclusion. CAD schemes can detect a substantial fraction of masses and microcalcification clusters depicted on prior images. To improve performance with prior images, the scheme may have to be adaptively reoptimized with increasingly more subtle abnormalities.
引用
收藏
页码:1245 / 1250
页数:6
相关论文
共 50 条
  • [41] Computer-aided detection with screening mammography: Improving performance or simply shifting the operating point?
    Sumkin, Jules H.
    Gur, David
    RADIOLOGY, 2006, 239 (03) : 916 - 917
  • [42] Impact of computer-aided detection in a regional screening mammography program
    Cupples, TE
    Cunningham, JE
    Reynolds, JC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) : 944 - 950
  • [43] Accuracy of segmentation of a commercial computer-aided detection system for mammography
    Baker, JA
    Rosen, EL
    Crockett, MM
    Lo, JY
    RADIOLOGY, 2005, 235 (02) : 385 - 390
  • [44] DIGITIZATION REQUIREMENTS IN MAMMOGRAPHY - EFFECTS ON COMPUTER-AIDED DETECTION OF MICROCALCIFICATIONS
    CHAN, HP
    NIKLASON, LT
    IKEDA, DM
    LAM, KL
    ADLER, DD
    MEDICAL PHYSICS, 1994, 21 (07) : 1203 - 1211
  • [45] A Computer-Aided Detection System for Automatic Mammography Mass Identification
    Samma, Hussein
    Lim, Chee Peng
    Samma, Ali
    NEURAL INFORMATION PROCESSING: MODELS AND APPLICATIONS, PT II, 2010, 6444 : 226 - 233
  • [46] Re: Effectiveness of Computer-Aided Detection in Community Mammography Practice
    Nishikawa, Robert M.
    Giger, Maryellen L.
    Jiang, Yulei
    Metz, Charles E.
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2012, 104 (01): : 77 - 77
  • [47] Computer-aided detection with screening mammography in a university hospital setting
    Birdwell, RL
    Bandodkar, P
    Ikeda, DM
    RADIOLOGY, 2005, 236 (02) : 451 - 457
  • [48] Computer-aided detection is an alternative to double-reading mammography
    不详
    Nature Clinical Practice Oncology, 2009, 6 (2): : 60 - 61
  • [49] Computer-aided diagnosis in screening mammography: Detection of missed cancers
    Nishikawa, RM
    Giger, M
    Schmidt, RA
    Collins, SA
    Doi, K
    RADIOLOGY, 1998, 209P : 353 - 353
  • [50] Estimating the effect of computer-aided detection on the sensitivity of screening mammography
    Sacks, WM
    RADIOLOGY, 2003, 226 (02) : 597 - 598