Operative Management of Distal Radial Fractures with 2.4-Millimeter Locking Plates: A Multicenter Prospective Case Series

被引:28
|
作者
Jupiter, Jesse B. [1 ]
Marent-Huber, M.
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Boston, MA 02114 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 2010年 / 92A卷
关键词
FIXATION;
D O I
10.2106/JBJS.I.01340
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: In the past decade, there has been a trend toward open reduction and internal fixation of unstable distal radial fractures. There are now more than thirty different implant designs specific for the fixation of distal radial fractures. A multicenter prospective study of a case series was conducted to determine the efficacy of the operative management of distal radial fractures stabilized with 2.4-mm locking plates. METHODS: One hundred and fifty patients were entered into the study over a two-year period. The mean age of these patients was fifty-one years, and the cohort included eighty-eight women and sixty-two men. Eighty-six patients sustained a low-energy injury. Seventy-one percent of the fractures in the series were intra-articular and were Type C according to the Muller-AO Comprehensive Classification. The follow-up evaluations, which were conducted at six weeks, six months, one year, and two years, included assessments of pain, motion, grip strength, and standard radiographs. Gartland and Werley scores were recorded at six months and one and two years, and Disabilities of the Arm, Shoulder and Hand (DASH) scores were recorded at one and two years. RESULTS: One hundred and twenty-five patients (83%) had a complete follow-up at six months; 121 (81%), at one year; and 117 (78%), at two years. Significant improvements in motion, grip strength, and patient satisfaction were observed between six months and one year, but further improvements were not seen at the two-year follow-up examination. The mean DASH score changed from a preinjury baseline of 2 points to 8 points at one year and 7 points at two years (p < 0.0001). The mean Gartland and Werley score improved significantly from 4 points at six months to 2 points at two years. Of the 102 intra-articular fractures examined in the immediate postoperative period, twenty had a step-off of <= 2 mm and seven had a step-off of >2 mm. Of the seventy-one intra-articular fractures seen at two years, sixty-one had no step-off, five had a step-off of <= 2 mm, and five had a step-off of >2 mm. Twenty-seven percent of the patients showed an increase of at least one grade in radiographic signs of arthritis at two years. There were twenty-eight complications, twenty of which were considered minor. Tendon inflammation occurred in nine patients. There were two tendon ruptures, one of which was due to a prominent dorsal screw tip placed through a volar plate and one of which was due to a prominent volar plate. Loss of reduction occurred in two patients, and screw loosening occurred in two patients. CONCLUSIONS: Internal fixation of displaced distal radial fractures with implants featuring locking screw fixation can result in good-to-excel lent outcomes with a limited number of complications.
引用
收藏
页码:96 / 106
页数:11
相关论文
共 50 条
  • [21] Dorsal approach and internal fixation of impacted intra-articular distal radius fractures with 2.4 mm locking plates
    De Smet, A.
    Lamouille, J.
    Vostrel, P.
    Loret, M.
    Hoffmeyer, P.
    Beaulieu, J. -Y.
    HAND SURGERY & REHABILITATION, 2016, 35 (03): : 203 - 209
  • [22] Comparative prospective study between medial and lateral distal tibial locking compression plates for distal third tibial fractures
    Sandeep Garg
    Vikram Khanna
    Mahaveer Prashad Goyal
    Narendra Joshi
    Amrut Borade
    Ishan Ghuse
    中华创伤杂志英文版, 2017, 20 (03) : 151 - 154
  • [23] Outcome of Distal Tibial Fractures fixed with Precontoured Periarticular Locking Plates using MIPO Technique: a case series of 60 patients
    Ali, Muhammad
    Saleem, Muhammad
    Sarwar, Muhammad Usman
    Hafeez, Zahid
    Younas, Aleena
    Ishtiaq, Muhammad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 301 - 303
  • [24] The efficacy of volar locking plates and external fixation for patients with unstable distal radial fractures: a meta-analysis
    Qu, Shuangwei
    Zhang, Binfei
    Shang, Kun
    Wang, Pengfei
    Wei, Xing
    Zhuang, Yan
    Zhang, Kun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (03): : 2097 - 2106
  • [25] Mono versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Yueju Liu
    Han Li
    Yingze Zhang
    International Orthopaedics, 2014, 38 : 1543 - 1543
  • [26] The Management of Aseptic Non-unions of Distal Femur Fractures with Anatomical Lateral Locking Plates
    Mukhopadhaya, John
    Ranjan, Rajeev
    Sinha, Amit Kumar
    Bhadani, Janki Sharan
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2022, 17 (03) : 137 - 143
  • [27] Mono versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Liu, Yueju
    Li, Han
    Zhang, Yingze
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1543 - 1543
  • [28] Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Hanschen, Marc
    Aschenbrenner, Ina M.
    Fehske, Kai
    Kirchhoff, Sonja
    Keil, Leonhard
    Holzapfel, Boris M.
    Winkler, Sebastian
    Fuechtmeier, Bernd
    Neugebauer, Rainer
    Luehrs, Sven
    Liener, Ulrich
    Biberthaler, Peter
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 857 - 863
  • [29] Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial
    Marc Hanschen
    Ina M. Aschenbrenner
    Kai Fehske
    Sonja Kirchhoff
    Leonhard Keil
    Boris M. Holzapfel
    Sebastian Winkler
    Bernd Fuechtmeier
    Rainer Neugebauer
    Sven Luehrs
    Ulrich Liener
    Peter Biberthaler
    International Orthopaedics, 2014, 38 : 857 - 863
  • [30] SURGICAL MANAGEMENT OF DISTAL TIBIAL FRACTURES BY LOCKING PLATE/IMIL NAILING - A PROSPECTIVE STUDY OF RESULTS
    Koduru, Satya Kumar
    Aswanikanth, T.
    Chalasani, Prashanth
    Raghav, Srinivas T.
    Rao, C. Hanumantha
    Siddharth, P.
    Reddy, Venu Gopal P.
    Gopal, Venu T.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (97): : 7129 - 7133