Background This study aims to compare the clinical results of patients with upper thoracic vertebral fractures treated with pedicle screw and posterior spinal fusion with preoperative surgical planning and 3-dimensional (3D) modeling and patients treated with freehand screws. Methods Fifty patients who underwent pedicle screw placement with a diagnosis of upper thoracic fracture between June 2018 and October 2020 were included in our study. Pedicle screws were used in 25 patients (group 1) after the planning was completed with the help of 3D preoperative printing and modeling. Pedicle screws were applied in 25 patients in the control group (group 2) using the freehand technique. Intraoperative bleeding amount, operation time, and correct screw placement data in both groups were recorded. Results The operation time was 134 +/- 22 minutes for group 1 and 152 +/- 38 minutes for group 2. The difference in operation times was found to be statistically significant (p < 0.05). Based on axial and sagittal reconstruction images, the accuracy rate of pedicle screw placement (grades 0 and 1) in group I was 96.6% compared to 83.6% in group II. The minor perforation rate (grade 1, <2 mm) was 5.8% in group I compared to 11.8% in group II. The moderate perforation rate (grade 2, 2-4 mm) was 3.4% in group I compared to 14% in group II. The severe perforation rate (grade 3, >4 mm) was 2.3% in group 11; however, misplaced screws were not associated with neurological deficits. The difference in overall accuracy rates between the two groups was significant (p < 0.05). Conclusions For 3D models of upper thoracic pellicle screw insertion, guide plates can be produced inexpensively and individually. It provides a new method for the accurate placement of upper thoracic pellicle screws with high accuracy and secure use in screw insertion.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Nora Conrads
    Jan-Peter Grunz
    Henner Huflage
    Karsten Sebastian Luetkens
    Philipp Feldle
    Katharina Grunz
    Stefan Köhler
    Thomas Westermaier
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3007 - 3013
  • [42] Thermodynamic Modeling and Control of Screw Extruder for 3D Printing
    Koga, Shumon
    Straub, David
    Diagne, Mamadou
    Krstic, Miroslav
    2018 ANNUAL AMERICAN CONTROL CONFERENCE (ACC), 2018, : 2551 - 2556
  • [43] Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases
    Li Lei
    Zhou Feng-hua
    Wang Huan
    Cui Shao-qian
    CHINESE JOURNAL OF TRAUMATOLOGY, 2008, 11 (06) : 323 - 328
  • [44] Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases
    李雷
    周凤华
    王欢
    崔少千
    中华创伤杂志(英文版), 2008, (06)
  • [45] A HISTORICAL COHORT STUDY OF PEDICLE SCREW FIXATION IN THORACIC, LUMBAR, AND SACRAL SPINAL FUSIONS
    YUAN, HA
    GARFIN, SR
    DICKMAN, CA
    MARDJETKO, SM
    SPINE, 1994, 19 (20) : S2279 - S2296
  • [46] Thoracic pedicle screw fixation under axial and perpendicular loadings: A comprehensive numerical analysis
    Bianco, Rohan-Jean
    Arnoux, Pierre-Jean
    Mac-Thiong, Jean-Marc
    Aubin, Carl-Eric
    CLINICAL BIOMECHANICS, 2019, 68 : 190 - 196
  • [47] RETRACTED: Feasibility Analysis of 3D Printing-Assisted Pedicle Screw Correction Surgery for Degenerative Scoliosis (Retracted Article)
    Chen, Xuanhuang
    Gao, Xiaoqiang
    Zheng, Feng
    Lin, Haibin
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2022, 2022
  • [48] Clinical applications and prospects of 3D printing guide templates in orthopaedics
    Meng, Meng
    Wang, Jinzuo
    Sun, Tianze
    Zhang, Wentao
    Zhang, Jing
    Shu, Liming
    Li, Zhonghai
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2022, 34 : 22 - 41
  • [49] Upper Thoracic Pedicle Screws Loss of Fixation Causing Spinal Cord Injury
    Sanpera, Ignacio, Jr.
    Piza-Vallespir, Gabriel
    Burgos-Flores, Jesus
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2014, 34 (06) : E39 - E39
  • [50] Evaluation of 2D and 3D navigation for iliosacral screw fixation
    Daniel Behrendt
    Maria Mütze
    Hanno Steinke
    Martin Koestler
    Christoph Josten
    Jörg Böhme
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 249 - 255