Are 3D Printing Templates an Advantage in Upper Thoracic Pedicle Screw Fixation?

被引:5
|
作者
Kaya, Ismail [1 ]
Cingoz, Ilker Deniz [1 ]
Sahin, Meryem Cansu [2 ]
Atar, Murat [3 ]
Ozyoruk, Safak [4 ]
Sayin, Murat [5 ]
Yuceer, Nurullah [6 ]
机构
[1] Usak Univ, Neurosurg, Usak, Turkey
[2] Kutahya Hlth Sci Univ, Med Phys, Kutahya, Turkey
[3] Abdulhamid Han Res & Training Hosp, Neurosurg, Istanbul, Turkey
[4] Private OEM Antalya Hosp, Neurosurg, Antalya, Turkey
[5] Private Saglik Hosp, Neurosurg, Izmir, Turkey
[6] Izmir Katip Celebi Univ, Neurosurg, Izmir, Turkey
关键词
3d printing; pedicle screw; preoperative plan; upper thoracic trauma; FREE-HAND; PLACEMENT; SPINE; ACCURACY; LUMBAR;
D O I
10.7759/cureus.13989
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This study aims to compare the clinical results of patients with upper thoracic vertebral fractures treated with pedicle screw and posterior spinal fusion with preoperative surgical planning and 3-dimensional (3D) modeling and patients treated with freehand screws. Methods Fifty patients who underwent pedicle screw placement with a diagnosis of upper thoracic fracture between June 2018 and October 2020 were included in our study. Pedicle screws were used in 25 patients (group 1) after the planning was completed with the help of 3D preoperative printing and modeling. Pedicle screws were applied in 25 patients in the control group (group 2) using the freehand technique. Intraoperative bleeding amount, operation time, and correct screw placement data in both groups were recorded. Results The operation time was 134 +/- 22 minutes for group 1 and 152 +/- 38 minutes for group 2. The difference in operation times was found to be statistically significant (p < 0.05). Based on axial and sagittal reconstruction images, the accuracy rate of pedicle screw placement (grades 0 and 1) in group I was 96.6% compared to 83.6% in group II. The minor perforation rate (grade 1, <2 mm) was 5.8% in group I compared to 11.8% in group II. The moderate perforation rate (grade 2, 2-4 mm) was 3.4% in group I compared to 14% in group II. The severe perforation rate (grade 3, >4 mm) was 2.3% in group 11; however, misplaced screws were not associated with neurological deficits. The difference in overall accuracy rates between the two groups was significant (p < 0.05). Conclusions For 3D models of upper thoracic pellicle screw insertion, guide plates can be produced inexpensively and individually. It provides a new method for the accurate placement of upper thoracic pellicle screws with high accuracy and secure use in screw insertion.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
    Guo, Fei
    Dai, Jianhao
    Zhang, Junxiang
    Ma, Yichuan
    Zhu, Guanghui
    Shen, Junjie
    Niu, Guoqi
    PLOS ONE, 2017, 12 (02):
  • [2] 3D printing–assisted preoperative plan of pedicle screw placement for middle-upper thoracic trauma: a cohort study
    Wei Xu
    Xuming Zhang
    Tie Ke
    Hongru Cai
    Xiang Gao
    BMC Musculoskeletal Disorders, 18
  • [3] Clinical Use of 3D Printing Guide Plate in Posterior Lumbar Pedicle Screw Fixation
    Chen, Hongliang
    Wu, Dongying
    Yang, Huilin
    Guo, Kaijin
    MEDICAL SCIENCE MONITOR, 2015, 21 : 3948 - 3954
  • [4] Biomechanical Comparison of Costotransverse Process Screw Fixation and Pedicle Screw Fixation of the Upper Thoracic Spine
    Little, Andrew S.
    Brasiliense, Leonardo B. C.
    Lazaro, Bruno C. R.
    Reyes, Phillip M.
    Dickman, Curtis A.
    Crawford, Neil R.
    NEUROSURGERY, 2010, 66 (03) : 178 - 182
  • [5] 3D printing-assisted preoperative plan of pedicle screw placement for middle-upper thoracic trauma: a cohort study
    Xu, Wei
    Zhang, Xuming
    Ke, Tie
    Cai, Hongru
    Gao, Xiang
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 348
  • [6] Biomechanical Comparison of Costotransverse Process Screw Fixation and Pedicle Screw Fixation of the Upper Thoracic Spine COMMENTS
    Maiman, Dennis J.
    Mummaneni, Praveen V.
    Traynelis, Vincent C.
    NEUROSURGERY, 2010, 66 (03) : 182 - 182
  • [7] Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine (vol 12, e0171509, 2017)
    Guo, F.
    Dai, J.
    Zhang, J.
    Ma, Y.
    Zhu, G.
    Shen, J.
    PLOS ONE, 2019, 14 (02):
  • [8] Efficacy of Pedicle Screw Fixation in Unstable Upper and Middle Thoracic Spine Fractures
    Ghasemi, Amir Abbas
    Ashoori, Soudabeh
    TRAUMA MONTHLY, 2016, 21 (01)
  • [9] Pedicle Screw Fixation of Thoracic Spine Fractures
    Bozik, M.
    Magala, M.
    Heger, T.
    Matejicka, D.
    Baka, J.
    Simko, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2014, 81 (02) : 140 - 151
  • [10] The safety of pedicle screw fixation in the thoracic spine
    Yalniz, Erol
    Ciftdemir, Mert
    Eskin, Deniz
    Dulger, Hakan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (06) : 522 - 527