The Application of Indocyanine Green Fluorescence Imaging During Robotic Liver Resection: A Case-Matched Study

被引:31
|
作者
Vito Marino, Marco [1 ,2 ]
Di Saverio, Salomone [3 ]
Podda, Mauro [4 ]
Gomez Ruiz, Marcos [2 ]
Gomez Fleitas, Manuel [5 ]
机构
[1] Azienda Osped Osped Riuniti Villa Sofia Cervello, Dept Emergency & Gen Surg, Via Trabucco 180, I-90146 Palermo, Italy
[2] Hosp Univ Marques Valdecilla, Dept Colorectal & Gen Surg, Ave Valdecilla 25z, Santander 39008, Spain
[3] Addenbrooke Univ Hosp NHS Fdn Trust, Cambridge Colorectal Unit, Hills Rd, Cambridge CB2 0QQ, England
[4] Cagliari Univ Hosp Policlin D Casula, Dept Gen Emergency & Minimally Invas Surg, SS 554 Km 4 500, I-09142 Cagliari, Italy
[5] Hosp Univ Marques Valdecilla, Dept Innovac & Cirugia Robot, Ave Valdecilla 25, Santander 39008, Spain
关键词
INTRAOPERATIVE IDENTIFICATION; SENTINEL NODE; SURGERY; HEPATECTOMY; NAVIGATION; SYSTEM; CANCER;
D O I
10.1007/s00268-019-05055-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The ICG fluorescence properties are progressively gaining momentum in the HPB surgery. However, the exact impact of ICG application on surgical outcomes is yet to be established. Methods Twenty-five patients who underwent ICG fluorescence-guided robotic liver resection were case-matched in a 1:1 ratio to a cohort who underwent standard robotic liver resection. Results In the ICG group, six additional lesions not diagnosed by preoperative workup and intraoperative ultrasound were identified and resected. Four of the lesions were proved to be malignant. Despite the similar operative time (288 vs. 272 min, p = 0.778), the risk of postoperative bile leakage (0% vs. 12%, p = 0.023), R1 resection (0% vs. 16%, p = 0.019) and readmission (p = 0.023) was reduced in the ICG group compared with the no-ICG group. Conclusions The ICG fluorescence is a real-time navigation tool which enables surgeons to enhance visualization of anatomical structures and overcome the disadvantages of minimally invasive liver resection. The procedure is not time-consuming, and its applications can reduce the postoperative complication rate in robotic liver surgery.
引用
收藏
页码:2595 / 2606
页数:12
相关论文
共 50 条
  • [31] Concomitant Use of Indocyanine Green Fluorescence Imaging and Interventional Radiology for Detection of Liver Segments During Laparoscopic Anatomical Liver Resection: Pilot Feasibility Study
    Ueno, Masaki
    Hayami, Shinya
    Sonomura, Tetsuo
    Kawai, Manabu
    Hirono, Seiko
    Okada, Ken-ichi
    Tanaka, Ryota
    Yamaue, Hiroki
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2019, 29 (04): : 242 - 246
  • [32] Indocyanine green fluorescence imaging to evaluate graft perfusion during liver transplantation
    Figueroa, Rodrigo
    Golse, Nicolas
    Alvarez, Fernando A.
    Ciacio, Oriana
    Pittau, Gabriella
    Cunha, Antonio Sa
    Cherqui, Daniel
    Adam, Rene
    Vibert, Eric
    HPB, 2019, 21 (04) : 387 - 392
  • [33] Hepatic Vein-oriented Liver Resection Using Fusion Indocyanine Green Fluorescence Imaging
    Inoue, Yosuke
    Saiura, Akio
    Arita, Junichi
    Takahashi, Yu
    ANNALS OF SURGERY, 2015, 262 (06) : E98 - E99
  • [34] Clinical effects of the use of the indocyanine green fluorescence imaging technique in laparoscopic partial liver resection
    Itoh, Shinji
    Tomiyama, Takahiro
    Morinaga, Akinari
    Kurihara, Takeshi
    Nagao, Yoshihiro
    Toshima, Takeo
    Morita, Kazutoyo
    Harada, Noboru
    Mori, Masaki
    Yoshizumi, Tomoharu
    ANNALS OF GASTROENTEROLOGICAL SURGERY, 2022, 6 (05): : 688 - 694
  • [35] Laparoscopic resection for rectal cancer: a case-matched study
    Andre da Luz Moreira
    Isabella Mor
    Daniel P. Geisler
    Feza H. Remzi
    Ravi P. Kiran
    Surgical Endoscopy, 2011, 25 : 278 - 283
  • [36] Laparoscopic resection for rectal cancer: a case-matched study
    Moreira, Andre da Luz
    Mor, Isabella
    Geisler, Daniel P.
    Remzi, Feza H.
    Kiran, Ravi P.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (01): : 278 - 283
  • [37] APPLICATION OF INDOCYANINE GREEN FLUORESCENCE FOR URETER IMAGING: REVIEW
    Smagulov, A. D.
    Rysmakhanov, M. S.
    Koishybayev, Zh M.
    Sultangereyev, Y. B.
    Mussin, N. M.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2022, 24 (01): : 31 - 35
  • [38] Clinical Application of Indocyanine Green Fluorescence Imaging in the Resection of Hepatoblastoma: A Single Institution's Experiences
    Shen, Yuanchao
    Zheng, Manna
    Li, Jiahao
    Tan, Tianbao
    Yang, Jiliang
    Pan, Jing
    Hu, Chao
    Zou, Yan
    Yang, Tianyou
    FRONTIERS IN SURGERY, 2022, 9
  • [39] The application of indocyanine green during robotic surgery for IBD
    Marino, M. V.
    Komorowski, A. L.
    JOURNAL OF CROHNS & COLITIS, 2018, 12 : S277 - S278
  • [40] Laparoscopic robotic-assisted pancreaticoduodenectomy: a case-matched comparison with open resection
    Chalikonda, S.
    Aguilar-Saavedra, J. R.
    Walsh, R. M.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (09): : 2397 - 2402