Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer

被引:32
|
作者
Schmid, Rainer W. [2 ]
Lotz, Johannes [3 ]
Schweigert, Rosemarie [3 ]
Lackner, Karl [3 ]
Aimo, Giuseppe [4 ]
Friese, Judith [1 ]
Rosiere, Thomas [1 ]
Dickson, Diana [5 ]
Kenney, Daniel [5 ]
Maine, Gregory T. [1 ]
机构
[1] Abbott Diagnost, Dept 09L5, Abbott Pk, IL 60064 USA
[2] Med Univ Vienna, Vienna, Austria
[3] Johannes Gutenberg Univ Mainz, Mainz, Germany
[4] Molinette Mauriziano Hosp, Turin, Italy
[5] Fujirebio Diagnost, Malvern, PA USA
关键词
Sirolimus; Rapamycin; Transplant; Immunoassay; CMIA; MEIA; LC/MS/MS; IMx; Monitoring; Immunosuppression; MASS-SPECTROMETRIC DETECTION; WHOLE-BLOOD; CALCINEURIN INHIBITORS; RAPAMYCIN; HPLC; TRANSPLANTATION; METABOLITES; MS/MS; ASSAY;
D O I
10.1016/j.clinbiochem.2009.06.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. Design and methods: Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. Results: The CMIA total %CV's were all <8% and the Limit of Quantification (LOQ) was <1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R >= 0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R >= 0.94 at 2 sites and mean biases of 5.4% and 6.9%. Conclusions: CMIA is a precise and sensitive immunoassay method without hematocrit interference. It correlates well to both LC/MS/MS and immunoassay results, but shows an expected positive bias to LC/MS/MS. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
下载
收藏
页码:1543 / 1548
页数:6
相关论文
共 50 条
  • [41] Analytical and clinical evaluation of assays for free and total triiodothyronine (T3) on the Abbott ARCHITECT® i2000® immunoassay analyzer.
    Finley, D
    Grenier, F
    Lou, E
    Syed, H
    Pestel, C
    Varughese, L
    Colloton, P
    Storck-Schattner, D
    Birkhoff, T
    CLINICAL CHEMISTRY, 2002, 48 (06) : A125 - A126
  • [42] European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay
    Krintus, Magdalena
    Kozinski, Marek
    Boudry, Pascal
    Estan Capell, Nuria
    Koeller, Ursula
    Lackner, Karl
    Lefevre, Guillaume
    Lennartz, Lieselotte
    Lotz, Johannes
    Mora Herranz, Antonio
    Nybo, Mads
    Plebani, Mario
    Sandberg, Maria B.
    Schratzberger, Wolfgang
    Shih, Jessie
    Skadberg, Oyvind
    Chargui, Ahmed Taoufik
    Zaninotto, Martina
    Sypniewska, Grazyna
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (11) : 1657 - 1665
  • [43] Alpha-site evaluation of the Abbott ARCHITECT c4000 clinical chemistry analyzer
    Kerekes, R.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A202 - A203
  • [44] Alpha-site evaluation of the Abbott ARCHITECT c4000 clinical chemistry analyzer
    Kerekes, R.
    Martin, A.
    Brown, P.
    Carlson, M. L.
    Johnston, G.
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1280 - 1281
  • [45] Performance evaluation and analytical characteristics of the Abbott AxSYM(R) carcinoembyonic antigen microparticle enzyme immunoassay.
    Zibrat, S
    Toney, L
    Sharma, N
    McLawhon, R
    CLINICAL CHEMISTRY, 1996, 42 (06) : 718 - 718
  • [46] Performance evaluation and analytical characteristics of the Abbott AxSYM alpha-fetoprotein microparticle enzyme immunoassay.
    Toney, LJ
    Sharma, N
    Zibrat, SJ
    McLawhon, RW
    CLINICAL CHEMISTRY, 1996, 42 (06) : 389 - 389
  • [47] Performance, evaluation and analytical characteristics of the Abbott IMx(R) beta(2) microglobulin microparticle immunoassay.
    Zibrat, S
    Erdmann, M
    Toney, L
    McLawhon, R
    CLINICAL CHEMISTRY, 1996, 42 (06) : 719 - 719
  • [48] A multi-site performance evaluation of Bayer Rapidlab® 1200 Analyzer
    Lynch, M.
    Vallen-Thompson, M.
    Canelli, G.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A82 - A82
  • [49] Identification of early HIV infections using the fourth generation Abbott ARCHITECT HIV Ag/Ab Combo chemiluminescent microparticle immunoassay (CIA) in San Diego County
    Manlutac, Anna Liza M.
    Giesick, Jill S.
    McVay, Patricia A.
    JOURNAL OF CLINICAL VIROLOGY, 2013, 58 : E44 - E47
  • [50] Evaluation of an immunoassay (Abbott-IMX Analyzer) allowing routine determination of sirolimus: Comparison with LC-MS method
    Bargnoux, A. S.
    Bonardet, A.
    Chong, G.
    Garrigue, V.
    Deleuze, S.
    Dupuy, A. M.
    Mourad, G.
    Cristol, J. P.
    TRANSPLANTATION PROCEEDINGS, 2006, 38 (07) : 2352 - 2353