Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI

被引:80
|
作者
Craven, B. C. [1 ,2 ]
Morris, A. R.
机构
[1] Toronto Rehabil Inst, Dept Med, Lyndhurst Ctr, Toronto, ON M4G 3V9, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
关键词
reliability; spasticity; spinal cord injury; modified Ashworth scale; lower extremity; SPINAL-CORD-INJURY; MUSCLE SPASTICITY; OUTCOME MEASURES; REFLEXES;
D O I
10.1038/sc.2009.107
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design: Observational study. Objectives: To report the intra-rater (one rater), inter-rater (two raters) and inter-session (one subject, sessions 1-5) reliability of lower extremity modified Ashworth scale (MAS) scores among patients with chronic spinal cord injury (SCI). Setting: Tertiary Academic Rehab Centre in Toronto, Canada. Methods: MAS scores of 20 subjects with chronic SCI (C5-T10 AIS A-D>12 months) were recorded for the hip abductors and adductors, knee flexors and extensors, and ankle plantar and dorsiflexors. MAS scores were assessed by two blinded raters (A and B) at the same time of day, weekly for 5 weeks using standardized test positions, a one-cycle per second metronome, with ratings recorded on the second cycle. MAS score reproducibility [intra-rater, inter-rater] were calculated using Cohen's Kappa. Intraclass correlation coefficients (ICCs) were calculated to determine inter-session ( trials 1-5) reliability; Kappa values >= 0.81 and ICC values >= 0.75 were desired. Results: Intra-rater reliability was fair to almost perfect (0.2<kappa<1.0) and differed between raters. Inter-rater reliability was poor-to-moderate (kappa<0.6) for all muscle groups. Inter-session reliability for a single rater was fair-to-good (0.4<ICC<0.75) for all muscle groups. Conclusions: MAS was not reliable as an intra-rater tool for all raters, and showed poor inter-rater and modest inter-session reliability. MAS has inadequate reliability for determining lower extremity spasticity between raters (inter-rater) or over time (inter-session). It is recommended that the rehabilitation science community seek alternative measures for quantifying spasticity. Spinal Cord (2010) 48, 207-213; doi: 10.1038/sc.2009.107; published online 29 September 2009
引用
收藏
页码:207 / 213
页数:7
相关论文
共 50 条
  • [21] Supporting Clinical Evaluation of Upper Limb Spasticity with Quantitative Data Measurement in Accordance to the Modified Ashworth Scale
    Othman, Nurul Atiqah
    Idris, Farhana
    Zakaria, Noor Ayuni Che
    Hanapiah, Fazah Akhtar
    Low, Cheng Yee
    [J]. 2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 731 - 736
  • [22] The influence of contractures and variation in measurement stretching velocity on the reliability of the Modified Ashworth Scale in patients with severe brain injury
    Mehrholz, J
    Major, Y
    Meissner, D
    Sandi-Gahun, S
    Koch, R
    Pohl, M
    [J]. CLINICAL REHABILITATION, 2005, 19 (01) : 63 - 72
  • [23] Assessing the reliability of the Modified Modified Ashworth Scale between two physiotherapists in adult patients with hemiplegia
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Fakhari, Zahra
    Mashayekhi, Masoud
    Herasi, Mona
    [J]. NEUROREHABILITATION, 2009, 25 (04) : 235 - 240
  • [24] Inter- and intra-rater reliability of the modified modified ashworth scale in the assessment of muscle spasticity in cerebral palsy: A preliminary study
    Ansari, Noureddin Nakhostin
    Rahimi, Maryam
    Naghdi, Soofia
    Barzegar-Ganji, Zahra
    Hasson, Scott
    Moghimi, Ehsan
    [J]. JOURNAL OF PEDIATRIC REHABILITATION MEDICINE, 2022, 15 (01) : 151 - 158
  • [25] Measurement of plantarflexor spasticity in traumatic brain injury - Correlational study of resistance torque compared with the modified Ashworth Scale
    Annaswamy, Thiru
    Mallempati, Srinivas
    Allison, Stephen C.
    Abraham, Lawrence D.
    [J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2007, 86 (05) : 404 - 411
  • [26] Reliability of the Modified Tardieu Scale and the Modified Ashworth Scale in adult patients with severe brain injury: a comparison study
    Mehrholz, J
    Wagner, K
    Meissner, D
    Grundmann, K
    Zange, C
    Koch, R
    Pohl, M
    [J]. CLINICAL REHABILITATION, 2005, 19 (07) : 751 - 759
  • [27] Inter- and intrarater reliability of the Ashworth Scale and the Disability Assessment Scale in patients with upper-limb poststroke spasticity
    Brashear, A
    Zafonte, R
    Corcoran, M
    Galvez-Jimenez, N
    Gracies, JM
    Gordon, MF
    Mcafee, A
    Ruffing, K
    Thompson, B
    Williams, M
    Lee, CH
    Turkel, C
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (10): : 1349 - 1354
  • [28] Inter-rater reliability of the Modified Modified Ashworth Scale as a clinical tool in measurements of post-stroke elbow flexor spasticity
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Mousakhani, Atefeh
    Nouriyan, Azam
    Omidvar, Zeinab
    [J]. NEUROREHABILITATION, 2009, 24 (03) : 225 - 229
  • [29] Artificial Neural Network Learns Clinical Assessment of Spasticity in Modified Ashworth Scale
    Park, Jeong-Ho
    Kim, Yushin
    Lee, Kwang-Jae
    Yoon, Yong-Soon
    Kang, Si Hyun
    Kim, Heesang
    Park, Hyung-Soon
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2019, 100 (10): : 1907 - 1915
  • [30] Test-retest reliability and inter-rater reliability of the Modified Tardieu Scale and the Modified Ashworth Scale in hemiplegic patients with stroke
    Li, F.
    Wu, Y.
    Li, X.
    [J]. EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2014, 50 (01) : 9 - 15