Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI

被引:80
|
作者
Craven, B. C. [1 ,2 ]
Morris, A. R.
机构
[1] Toronto Rehabil Inst, Dept Med, Lyndhurst Ctr, Toronto, ON M4G 3V9, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
关键词
reliability; spasticity; spinal cord injury; modified Ashworth scale; lower extremity; SPINAL-CORD-INJURY; MUSCLE SPASTICITY; OUTCOME MEASURES; REFLEXES;
D O I
10.1038/sc.2009.107
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design: Observational study. Objectives: To report the intra-rater (one rater), inter-rater (two raters) and inter-session (one subject, sessions 1-5) reliability of lower extremity modified Ashworth scale (MAS) scores among patients with chronic spinal cord injury (SCI). Setting: Tertiary Academic Rehab Centre in Toronto, Canada. Methods: MAS scores of 20 subjects with chronic SCI (C5-T10 AIS A-D>12 months) were recorded for the hip abductors and adductors, knee flexors and extensors, and ankle plantar and dorsiflexors. MAS scores were assessed by two blinded raters (A and B) at the same time of day, weekly for 5 weeks using standardized test positions, a one-cycle per second metronome, with ratings recorded on the second cycle. MAS score reproducibility [intra-rater, inter-rater] were calculated using Cohen's Kappa. Intraclass correlation coefficients (ICCs) were calculated to determine inter-session ( trials 1-5) reliability; Kappa values >= 0.81 and ICC values >= 0.75 were desired. Results: Intra-rater reliability was fair to almost perfect (0.2<kappa<1.0) and differed between raters. Inter-rater reliability was poor-to-moderate (kappa<0.6) for all muscle groups. Inter-session reliability for a single rater was fair-to-good (0.4<ICC<0.75) for all muscle groups. Conclusions: MAS was not reliable as an intra-rater tool for all raters, and showed poor inter-rater and modest inter-session reliability. MAS has inadequate reliability for determining lower extremity spasticity between raters (inter-rater) or over time (inter-session). It is recommended that the rehabilitation science community seek alternative measures for quantifying spasticity. Spinal Cord (2010) 48, 207-213; doi: 10.1038/sc.2009.107; published online 29 September 2009
引用
收藏
页码:207 / 213
页数:7
相关论文
共 50 条
  • [1] Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI
    B C Craven
    A R Morris
    [J]. Spinal Cord, 2010, 48 : 207 - 213
  • [2] Measurement of lower-limb muscle spasticity: Intrarater reliability of Modified Modified Ashworth Scale
    Ghotbi, Nastaran
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (01): : 83 - 88
  • [3] INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY
    BOHANNON, RW
    SMITH, MB
    [J]. PHYSICAL THERAPY, 1987, 67 (02): : 206 - 207
  • [4] Inter-rater reliability of the Modified Modified Ashworth Scale in assessing lower limb muscle spasticity
    Ghotbi, Nastaran
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Jamshidpour, Boushra
    Amiri, Somayeh
    [J]. BRAIN INJURY, 2009, 23 (10) : 815 - 819
  • [5] Inter-rater reliability of the Modified Ashworth Scale and modified Modified Ashworth Scale in assessing poststroke elbow flexor spasticity
    Kaya, Taciser
    Karatepe, Altinay Goksel
    Gunaydin, Rezzan
    Koc, Aysegul
    Ercan, Ulku Altundal
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2011, 34 (01) : 59 - 64
  • [6] Intraobserver reliability of modified Ashworth scale and modified Tardieu scale in the assessment of spasticity in children with cerebral palsy
    Numanoglu, Ayse
    Gunel, Mintaze Kerem
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (03) : 196 - 200
  • [7] Reliability of the Modified Ashworth Scale in the assessment of plantar flexor muscle spasticity in patients with traumatic brain injury
    Allison, SC
    Abraham, LD
    Petersen, CL
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1996, 19 (01) : 67 - 78
  • [8] The inter rater reliability of the original and of the modified Ashworth scale for the assessment of spasticity in patients with spinal cord injury
    Haas, BM
    Bergstrom, E
    Jamous, A
    Bennie, A
    [J]. SPINAL CORD, 1996, 34 (09) : 560 - 564
  • [9] Reliability of the Tone Assessment Scale and the modified Ashworth scale as clinical tools for assessing poststroke spasticity
    Gregson, JM
    Leathley, M
    Moore, AP
    Sharma, AK
    Smith, TL
    Watkins, CL
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (09): : 1013 - 1016
  • [10] Reliability of the Modified Ashworth Scale and Modified Tardieu Scale in patients with spinal cord injuries
    P Akpinar
    A Atici
    F U Ozkan
    I Aktas
    D G Kulcu
    A Sarı
    B Durmus