Individual radiation therapy patient whole-body phantoms for peripheral dose evaluations: method and specific software

被引:15
|
作者
Alziar, I. [1 ,2 ,3 ,4 ]
Bonniaud, G. [4 ]
Couanet, D. [4 ]
Ruaud, J. B. [5 ]
Vicente, C. [1 ,2 ,3 ,4 ]
Giordana, G. [1 ,2 ,3 ,4 ]
Ben-Harrath, O. [1 ,2 ,3 ,4 ]
Diaz, J. C. [5 ]
Grandjean, P. [5 ]
Kafrouni, H. [5 ]
Chavaudra, J. [4 ]
Lefkopoulos, D. [4 ]
de Vathaire, F. [1 ,2 ,3 ,4 ]
Diallo, I. [1 ,2 ,3 ,4 ]
机构
[1] INSERM, U605, Villejuif, France
[2] IFR69, Villejuif, France
[3] Univ Paris 11, Villejuif, France
[4] Inst Gustave Roussy, Villejuif, France
[5] DOSIsoft, Cachan, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 17期
关键词
PROTECTION DOSIMETRY; RADIOTHERAPY; VOLUME; CHILDHOOD; EXPOSURES; CANCER; RISK; ICTA;
D O I
10.1088/0031-9155/54/17/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study presents a method aimed at creating radiotherapy (RT) patient-adjustable whole-body phantoms to permit retrospective and prospective peripheral dose evaluations for enhanced patient radioprotection. Our strategy involves virtual whole-body patient models (WBPM) in different RT treatment positions for both genders and for different age groups. It includes a software tool designed to match the anatomy of the phantoms with the anatomy of the actual patients, based on the quality of patient data available. The procedure for adjusting a WBPM to patient morphology includes typical dimensions available in basic auxological tables for the French population. Adjustment is semi-automatic. Because of the complexity of the human anatomy, skilled personnel are required to validate changes made in the phantom anatomy. This research is part of a global project aimed at proposing appropriate methods and software tools capable of reconstituting the anatomy and dose evaluations in the entire body of RT patients in an adapted treatment planning system (TPS). The graphic user interface is that of a TPS adapted to obtain a comfortable working process. Such WBPM have been used to supplement patient therapy planning images, usually restricted to regions involved in treatment. Here we report, as an example, the case of a patient treated for prostate cancer whose therapy planning images were complemented by an anatomy model. Although present results are preliminary and our research is ongoing, they appear encouraging, since such patient-adjusted phantoms are crucial in the optimization of radiation protection of patients and for follow-up studies.
引用
收藏
页码:N375 / N383
页数:9
相关论文
共 50 条
  • [21] Patient-Specific Meshless Model for Whole-Body Image Registration
    Li, Mao
    Miller, Karol
    Joldes, Grand
    Kikinis, Ron
    Wittek, Adam
    [J]. BIOMEDICAL SIMULATION, 2014, 8789 : 50 - 57
  • [22] STANDARDIZATION OF CALIBRATION METHOD OF WHOLE-BODY COUNTER .1. CALIBRATION BY USING ANTHROPOMETRIC PHANTOMS
    ISHIKAWA, T
    MATSUMOTO, M
    UCHIYAMA, M
    MIZUSHITA, S
    KOBAYASHI, S
    [J]. JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1995, 37 (05): : 420 - 429
  • [23] AI Transformers for Radiation Dose Reduction in Serial Whole-Body PET Scans
    Wang, Yan-Ran
    Qu, Liangqiong
    Sheybani, Natasha Diba
    Luo, Xiaolong
    Wang, Jiangshan
    Hawk, Kristina Elizabeth
    Theruvath, Ashok Joseph
    Gatidis, Sergios
    Xiao, Xuerong
    Pribnow, Allison
    Rubin, Daniel
    Daldrup-Link, Heike E.
    [J]. RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2023, 5 (03)
  • [24] Cumulative Total Effective Whole-Body Radiation Dose in Critically Ill Patients
    Rohner, Deborah J.
    Bennett, Suzanne
    Samaratunga, Chandrasiri
    Jewell, Elizabeth S.
    Smith, Jeffrey P.
    Gaskill-Shipley, Mary
    Lisco, Steven J.
    [J]. CHEST, 2013, 144 (05) : 1481 - 1486
  • [25] Whole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk
    Huang, Bingsheng
    Law, Martin Wai-Ming
    Khong, Pek-Lan
    [J]. RADIOLOGY, 2009, 251 (01) : 166 - 174
  • [26] Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT
    Jallow, Ngoneh
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John M.
    Nye, Jonathon A.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02): : 238 - 241
  • [27] Estimation of the counting efficiencies for individual subjects in Cs-137 whole-body counting, using voxel phantoms
    Ishikawa, T
    Uchiyama, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 71 (03) : 195 - 200
  • [28] Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models
    Lee, Choonsik
    Lodwick, Daniel
    Hasenauer, Deanna
    Williams, Jonathan L.
    Lee, Choonik
    Bolch, Wesley E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12): : 3309 - 3333
  • [30] Usefulness of the patient-specific contrast enhancement optimizer simulation software during the whole-body computed tomography angiography
    Takanori Masuda
    Toru Higaki
    Takeshi Nakaura
    Yoshinori Funama
    Yoriaki Matsumoto
    Tomoyasu Sato
    Tomokazu Okimoto
    Rumi Gotanda
    Keiko Arao
    Hiromasa Imaizumi
    Shinichi Arao
    Junichi Hiratsuka
    Kazuo Awai
    [J]. Heart and Vessels, 2022, 37 : 1446 - 1452