Individual radiation therapy patient whole-body phantoms for peripheral dose evaluations: method and specific software

被引:15
|
作者
Alziar, I. [1 ,2 ,3 ,4 ]
Bonniaud, G. [4 ]
Couanet, D. [4 ]
Ruaud, J. B. [5 ]
Vicente, C. [1 ,2 ,3 ,4 ]
Giordana, G. [1 ,2 ,3 ,4 ]
Ben-Harrath, O. [1 ,2 ,3 ,4 ]
Diaz, J. C. [5 ]
Grandjean, P. [5 ]
Kafrouni, H. [5 ]
Chavaudra, J. [4 ]
Lefkopoulos, D. [4 ]
de Vathaire, F. [1 ,2 ,3 ,4 ]
Diallo, I. [1 ,2 ,3 ,4 ]
机构
[1] INSERM, U605, Villejuif, France
[2] IFR69, Villejuif, France
[3] Univ Paris 11, Villejuif, France
[4] Inst Gustave Roussy, Villejuif, France
[5] DOSIsoft, Cachan, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 17期
关键词
PROTECTION DOSIMETRY; RADIOTHERAPY; VOLUME; CHILDHOOD; EXPOSURES; CANCER; RISK; ICTA;
D O I
10.1088/0031-9155/54/17/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study presents a method aimed at creating radiotherapy (RT) patient-adjustable whole-body phantoms to permit retrospective and prospective peripheral dose evaluations for enhanced patient radioprotection. Our strategy involves virtual whole-body patient models (WBPM) in different RT treatment positions for both genders and for different age groups. It includes a software tool designed to match the anatomy of the phantoms with the anatomy of the actual patients, based on the quality of patient data available. The procedure for adjusting a WBPM to patient morphology includes typical dimensions available in basic auxological tables for the French population. Adjustment is semi-automatic. Because of the complexity of the human anatomy, skilled personnel are required to validate changes made in the phantom anatomy. This research is part of a global project aimed at proposing appropriate methods and software tools capable of reconstituting the anatomy and dose evaluations in the entire body of RT patients in an adapted treatment planning system (TPS). The graphic user interface is that of a TPS adapted to obtain a comfortable working process. Such WBPM have been used to supplement patient therapy planning images, usually restricted to regions involved in treatment. Here we report, as an example, the case of a patient treated for prostate cancer whose therapy planning images were complemented by an anatomy model. Although present results are preliminary and our research is ongoing, they appear encouraging, since such patient-adjusted phantoms are crucial in the optimization of radiation protection of patients and for follow-up studies.
引用
收藏
页码:N375 / N383
页数:9
相关论文
共 50 条
  • [1] Synthetic patient-specific whole-body CT for the calculation of peripheral dose during radiotherapy
    Munoz, I.
    Sanchez-Nieto, B.
    Espinoza, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1341 - S1342
  • [2] IS2aR, a computational tool to transform voxelized reference phantoms into patient-specific whole-body virtual CTs for peripheral dose estimation
    Munoz-Hernandez, Isidora Sofia
    Espinoza, Ignacio
    Lopez-Martinez, Ignacio N.
    Sanchez-Nieto, Beatriz
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 116
  • [3] Generating Patient-Specific Dosimetry Phantoms with Whole-Body Diffeomorphic Image Registration
    Tward, D. J.
    Ceritoglu, C.
    Sturgeon, G.
    Segars, W. P.
    Miller, M. I.
    Ratnanather, J. T.
    [J]. 2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2011,
  • [4] Patient-specific radiation dose for Chinese pediatric patients undergoing whole-body PET/CT examinations
    Jia, Haoran
    Xue, Mengjia
    Li, Xianru
    Zhuang, Mingzan
    Xie, Tianwu
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):
  • [5] Measurements of the equivalent whole-body dose during radiation therapy by cytogenetic methods
    Durante, M
    Yamada, S
    Ando, K
    Furusawa, Y
    Kawata, T
    Majima, H
    Nakano, T
    Tsujii, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05): : 1289 - 1298
  • [6] A patient-specific hybrid phantom for calculating radiation dose and equivalent dose to the whole body
    Kollitz, Erika
    Han, Haegin
    Kim, Chan Hyeong
    Pinto, Marco
    Schwarz, Marco
    Riboldi, Marco
    Kamp, Florian
    Belka, Claus
    Newhauser, Wayne
    Dedes, George
    Parodi, Katia
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03):
  • [7] Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body
    Tward, Daniel J.
    Ceritoglu, Can
    Kolasny, Anthony
    Sturgeon, Gregory M.
    Segars, W. Paul
    Miller, Michael I.
    Ratnanather, J. Tilak
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2011, 2011
  • [8] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [9] METHOD AND EQUIPMENT FOR WHOLE-BODY SCINTIGRAPHY UNDER HIGH-DOSE RADIONUCLIDE THERAPY
    DORING, V
    [J]. NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1985, 16 (02): : 90 - &
  • [10] Patient-specific whole-body dosimetry: Principles and a simplified method for clinical implementation
    Wahl, RL
    Kroll, S
    Zasadny, KR
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08): : 14S - 20S