Quantitative assessment of placental perfusion by contrast-enhanced ultrasound in macaques and human subjects

被引:47
|
作者
Roberts, Victoria H. J. [1 ]
Lo, Jamie O. [3 ]
Salati, Jennifer A. [3 ]
Lewandowski, Katherine S. [1 ]
Lindner, Jonathan R. [5 ]
Morgan, Terry K. [3 ,4 ]
Frias, Antonio E. [1 ,2 ,3 ]
机构
[1] Oregon Hlth & Sci Univ, Div Diabet Obes & Metab, Oregon Natl Primate Res Ctr, Beaverton, OR USA
[2] Oregon Hlth & Sci Univ, Div Reprod & Dev Sci, Oregon Natl Primate Res Ctr, Beaverton, OR USA
[3] Oregon Hlth & Sci Univ, Dept Obstet & Gynecol, Portland, OR 97201 USA
[4] Oregon Hlth & Sci Univ, Dept Pathol, Portland, OR 97201 USA
[5] Oregon Hlth & Sci Univ, Knight Cardiovasc Inst, Portland, OR 97201 USA
基金
美国国家卫生研究院;
关键词
contrast-enhanced ultrasound imaging; Japanese macaque; placenta; placental perfusion; NONHUMAN-PRIMATES; BLOOD-FLOW; MICROBUBBLES; PREGNANCY; DEFINITY;
D O I
10.1016/j.ajog.2016.01.001
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: The uteroplacental vascular supply is a critical determinant of placental function and fetal growth. Current methods for the in vivo assessment of placental blood flow are limited. OBJECTIVE: We demonstrate the feasibility of the use of contrast-enhanced ultrasound imaging to visualize and quantify perfusion kinetics in the intervillous space of the primate placenta. STUDY DESIGN: Pregnant Japanese macaques were studied at mid second trimester and in the early third trimester. Markers of injury were assessed in placenta samples from animals with or without contrastenhanced ultrasound exposure (n = 6/group). Human subjects were recruited immediately before scheduled first-trimester pregnancy termination. All studies were performed with maternal intravenous infusion of lipid-shelled octofluoropropane microbubbles with image acquisition with a multipulse contrast-specific algorithm with destruction-replenishment analysis of signal intensity for assessment of perfusion. RESULTS: In macaques, the rate of perfusion in the intervillous space was increased with advancing gestation. No evidence of microvascular hemorrhage or acute inflammation was found in placental villous tissue and expression levels of caspase-3, nitrotyrosine and heat shock protein 70 as markers of apoptosis, nitrative, and oxidative stress, respectively, were unchanged by contrast-enhanced ultrasound exposure. In humans, placental perfusion was visualized at 11 weeks gestation, and preliminary data reveal regional differences in intervillous space perfusion within an individual placenta. By electron microscopy, we demonstrate no evidence of ultrastructure damage to the microvilli on the syncytiotrophoblast after first-trimester ultrasound studies. CONCLUSIONS: Use of contrast-enhanced ultrasound did not result in placental structural damage and was able to identify intervillous space perfusion rate differences within a placenta. Contrast-enhanced ultrasound imaging may offer a safe clinical tool for the identification of pregnancies that are at risk for vascular insufficiency; early recognition may facilitate intervention and improved pregnancy outcomes.
引用
收藏
页码:369.e1 / 369.e8
页数:8
相关论文
共 50 条
  • [31] Quantitative Contrast-Enhanced Perfusion Measurements of the Human Lung Using the Prebolus Approach
    Oechsner, Markus
    Muehlhaeusler, Matti
    Ritter, Christian O.
    Weininger, Markus
    Beissert, Matthias
    Jakob, Peter M.
    Beer, Meinrad
    Hahn, Dietbert
    Koestler, Herbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) : 104 - 111
  • [32] Quantitative assessment of spinal cord perfusion by using contrast-enhanced ultrasound in a porcine model with acute spinal cord contusion
    Huang, L.
    Lin, X.
    Tang, Y.
    Yang, R.
    Li, A-h
    Ye, J-c
    Chen, K.
    Wang, P.
    Shen, H-y
    SPINAL CORD, 2013, 51 (03) : 196 - 201
  • [33] Quantitative assessment of spinal cord perfusion by using contrast-enhanced ultrasound in a porcine model with acute spinal cord contusion
    L Huang
    X Lin
    Y Tang
    R Yang
    A-h Li
    J-c Ye
    K Chen
    P Wang
    H-y Shen
    Spinal Cord, 2013, 51 : 196 - 201
  • [34] Contrast-enhanced ultrasound for quantitative assessment of portal pressure in canine liver fibrosis
    Zhai, Lin
    Qiu, Lan-Yan
    Zu, Yuan
    Yan, Yan
    Ren, Xiao-Zhuan
    Zhao, Jun-Feng
    Liu, Yu-Jiang
    Liu, Ji-Bin
    Qian, Lin-Xue
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (15) : 4509 - 4516
  • [35] Assessment of Global Liver Blood Flow With Quantitative Dynamic Contrast-Enhanced Ultrasound
    Gauthier, Thomas P.
    Wasan, Harpreet S.
    Muhammad, Aun
    Owen, David R.
    Leen, Edward L. S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (03) : 379 - 385
  • [36] Reproducibility of Quantitative Assessment of Altered Hepatic Hemodynamics With Dynamic Contrast-Enhanced Ultrasound
    Gauthier, Thomas P.
    Muhammad, Aun
    Wasan, Harpreet S.
    Abel, Paul D.
    Leen, Edward L. S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (09) : 1413 - 1420
  • [37] Contrast-enhanced ultrasound for quantitative assessment of portal pressure in canine liver fibrosis
    Lin Zhai
    Lan-Yan Qiu
    Yuan Zu
    Yan Yan
    Xiao-Zhuan Ren
    Jun-Feng Zhao
    Yu-Jiang Liu
    Ji-Bin Liu
    Lin-Xue Qian
    World Journal of Gastroenterology, 2015, 21 (15) : 4509 - 4516
  • [38] REAL-TIME CONTRAST-ENHANCED ULTRASOUND FOR THE ASSESSMENT OF PERFUSION DYNAMICS IN SKELETAL MUSCLE
    Krix, Martin
    Krakowski-Roosen, Holger
    Kauczor, Hans-Ulrich
    Delorme, Stefan
    Weber, Marc-Andre
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (10): : 1587 - 1595
  • [39] Assessment of Cancer Perfusion with Contrast-Enhanced Ultrasound Imaging and Relationship to Intratumoral Pressure Measures
    James, Dominique
    Song, Jane
    Li, Junjie
    Forsberg, Flemming
    Nam, Kibo
    Hoyt, Kenneth
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [40] Assessment of renal perfusion with contrast-enhanced ultrasound: Preliminary results in early diabetic nephropathies
    Dong, Yi
    Wang, Wen-Ping
    Lin, Pan
    Fan, Peili
    Mao, Feng
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 62 (03) : 229 - 238