A PERFORMANCE COMPARISON OF FIXED EJECTORS WITH AND WITHOUT A SWIRL GENERATOR AND CONTROLLABLE EJECTORS IN A CO2 REFRIGERATION SYSTEM

被引:0
|
作者
Smolka, Jacek [1 ]
Palacz, Michal [1 ]
Haida, Michal [1 ]
Bodys, Jakub [1 ]
Bulinski, Zbigniew [1 ]
Nowak, Andrzej J. [1 ]
Fic, Adam [1 ]
Banasiak, Krzysztof [2 ]
Hafner, Armin [3 ]
机构
[1] Silesian Tech Univ, PL-44100 Gliwice, Poland
[2] SINTEF Energy Res, N-7465 Trondheim, Norway
[3] Norwegian Univ Sci & Technol, N-7465 Trondheim, Norway
关键词
CO2; ejector; fixed ejector; controllable ejector; ejector performance; CO2 refrigeration unit; COMPUTATIONAL MODEL; EXPANSION WORK; R744; EJECTOR; 2-PHASE; CFD; ENHANCEMENT; STEAM;
D O I
10.18462/iir.gl.2016.1185
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper provides a performance comparison ejector technology to be installed in a CO2 supermarket refrigeration system. Namely, the fixed ejectors with and without swirl flow at the inlet of the motive and suction nozzles and the fixed and controllable ejectors equipped with convergent and convergent-divergent nozzles and were analysed. The Coefficient of Performance (COP) of the ejector-based refrigeration system is dependent on the design and control of the mass flow rate through this device. The literature suggests that one of the possible ejector efficiency improvements can be performed using a swirl generator at the inlet of the motive nozzle. Therefore, a swirl generator was simulated for different size CO2 ejectors under typical operating conditions in a supermarket and for a range of rotational speeds. In addition, the performance of a group of fixed ejectors working in parallel was compared with two controllable ejectors with a needle. To analyse the potential of the considered approaches, the device performance was numerically simulated using the validated Homogeneous Equilibrium Model (HEM) model for the same typical transcritical parameters. For all the fixed ejectors with and without the swirl generator, devices of various sizes were simulated and compared with the corresponding controllable ejector performance at a few needle positions. For both ejector types, a global efficiency as a function of the mass flow rate was presented and discussed.
引用
下载
收藏
页码:1093 / 1100
页数:8
相关论文
共 50 条
  • [1] Performance comparison of fixed- and controllable-geometry ejectors in a CO2 refrigeration system
    Smolka, Jacek
    Palacz, Michal
    Bodys, Jakub
    Banasiak, Krzysztof
    Fic, Adam
    Bulinski, Zbigniew
    Nowak, Andrzej J.
    Hafner, Armin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 65 : 172 - 182
  • [2] Performance of fixed geometry ejectors with a swirl motion installed in a multi-ejector module of a CO2 refrigeration system
    Bodys, Jakub
    Smolka, Jacek
    Palacz, Michal
    Haida, Michal
    Banasiak, Krzysztof
    Nowak, Andrzej J.
    Hafner, Armin
    ENERGY, 2016, 117 : 620 - 631
  • [3] Investigation on performance of variable geometry ejectors for CO2 refrigeration cycles
    Liu, Fang
    Groll, Eckhard A.
    Li, Daqing
    ENERGY, 2012, 45 (01) : 829 - 839
  • [4] Optimum pressure control with three controllable ejectors of a CO2 multi-ejector refrigeration system
    Li, Ligeng
    Tian, Hua
    Liu, Kai
    Wu, Yibo
    Wang, Xuan
    Liang, Xingyu
    Shu, Gequn
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 157 : 172 - 185
  • [5] The Performance Analysis of an Integrated CO2 Refrigeration System with Multi-Ejectors Installed in a Supermarket
    Soylemez, Engin
    Hafner, Armin
    Schlemminger, Christian
    Kriezi, Ekaterini E.
    Khorshidi, Vahid
    ENERGIES, 2022, 15 (09)
  • [6] Thermodynamic analysis of rotary pressure exchanger and ejectors for CO2 refrigeration system
    Saeed, Muhammad Zahid
    Pardinas, Angel Alvarez
    Banasiak, Krzysztof
    Hafner, Armin
    Thatte, Azam
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 51
  • [7] A novel transcritical CO2 refrigeration cycle with two ejectors
    Cen, Jiwen
    Liu, Pei
    Jiang, Fangming
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2233 - 2239
  • [8] Modelling, Optimization, and Experimental Studies of Refrigeration CO2 Ejectors: A Review
    Zheng, Lixing
    Zhang, Yiyan
    Hao, Lifen
    Lian, Haojie
    Deng, Jianqiang
    Lu, Wei
    MATHEMATICS, 2022, 10 (22)
  • [9] Thermodynamic modeling and performance optimization of transcritical CO2 2 dual-evaporator refrigeration system enhanced with ejectors
    Shu, Yuetong
    Yan, Jia
    APPLIED THERMAL ENGINEERING, 2024, 249
  • [10] Analysis of the exergy transfers in subcritical and transcritical CO2 ejectors and their connection with the performance of the refrigeration cycle
    Metsue, Antoine
    Nesreddine, Hakim
    Bodys, Jakub
    Poncet, Sébastien
    Bartosiewicz, Yann
    Energy, 2024, 311