The Performance Analysis of an Integrated CO2 Refrigeration System with Multi-Ejectors Installed in a Supermarket

被引:1
|
作者
Soylemez, Engin [1 ]
Hafner, Armin [1 ]
Schlemminger, Christian [2 ]
Kriezi, Ekaterini E. [3 ]
Khorshidi, Vahid [3 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Energy & Proc Engn, Proc & Power Res Grp Trondheim, N-7491 Trondheim, Norway
[2] Sintef Energy Res, Dept Thermal Energy, N-7465 Trondheim, Norway
[3] RAC R&D Danfoss AS, Nordborgvej 81, DK-6430 Nordborg, Denmark
基金
欧盟地平线“2020”;
关键词
R-744; integrated CO2; supermarket; transcritical; ejectors; power consumption; refrigeration; ENERGY ANALYSIS; CONFIGURATIONS;
D O I
10.3390/en15093142
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The field data from an integrated CO2 refrigeration system installed in a supermarket located north of the capital of Lisbon was analyzed. The goal was to demonstrate the effect and performance of multi-ejectors on a refrigeration system operating in a warm climate. The measurement results for the system with and without activating ejectors were compared. It was observed that the system with a multi-ejector operation had considerable performance superiority. The ejectors improved the cooling capacity of the medium temperature stage of the system by 17.4%. The system with active ejectors had 7.5% less total power consumption compared to the ejector off mode of the same system.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] PARALLEL WORK OF CO2 EJECTORS INSTALLED IN A MULTI-EJECTOR MODULE OF REFRIGERATION SYSTEM
    Bodys, Jakub
    Palacz, Michal
    Haida, Michal
    Smolka, Jacek
    Nowak, Andrzej J.
    Banasiak, Krzysztof
    Hafner, Armin
    [J]. 7TH EUROPEAN THERMAL-SCIENCES CONFERENCE (EUROTHERM2016), 2016, 745
  • [2] Performance of fixed geometry ejectors with a swirl motion installed in a multi-ejector module of a CO2 refrigeration system
    Bodys, Jakub
    Smolka, Jacek
    Palacz, Michal
    Haida, Michal
    Banasiak, Krzysztof
    Nowak, Andrzej J.
    Hafner, Armin
    [J]. ENERGY, 2016, 117 : 620 - 631
  • [3] PERFORMANCE ANALYSIS OF TRANSCRITICAL CO2 REFRIGERATION SYSTEM FOR SUPERMARKET APPLICATION
    Santosa, IDewa M. C.
    Sudirman
    Ing, Suta Waisnawa
    [J]. INTERNATIONAL JOURNAL OF GEOMATE, 2018, 15 (50): : 70 - 75
  • [4] Performance Analysis of Supermarket Subcooling CO2 Refrigeration System Integrated With Seasonal Borehole Cold Energy Storage
    Dai, Baomin
    Meng, Chenyang
    Zhou, Xuan
    Cao, Yu
    Zhao, Ruirui
    Yang, Peifang
    Wang, Qi
    Liu, Shengchun
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (11): : 3039 - 3045
  • [5] A PERFORMANCE COMPARISON OF FIXED EJECTORS WITH AND WITHOUT A SWIRL GENERATOR AND CONTROLLABLE EJECTORS IN A CO2 REFRIGERATION SYSTEM
    Smolka, Jacek
    Palacz, Michal
    Haida, Michal
    Bodys, Jakub
    Bulinski, Zbigniew
    Nowak, Andrzej J.
    Fic, Adam
    Banasiak, Krzysztof
    Hafner, Armin
    [J]. 12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 1093 - 1100
  • [6] Thermodynamic analysis of rotary pressure exchanger and ejectors for CO2 refrigeration system
    Saeed, Muhammad Zahid
    Pardinas, Angel Alvarez
    Banasiak, Krzysztof
    Hafner, Armin
    Thatte, Azam
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 51
  • [7] Performance evaluation of CO2 supermarket refrigeration system with multi-ejector and dedicated mechanical subcooling
    Liu, Xi
    Yu, Kaihong
    Wan, Xinchen
    Li, Xuelai
    [J]. ENERGY REPORTS, 2021, 7 : 5214 - 5227
  • [8] Energy analysis and performance comparison of transcritical CO2 supermarket refrigeration cycles
    Caliskan, Oguz
    Ersoy, H. Kursad
    [J]. JOURNAL OF SUPERCRITICAL FLUIDS, 2022, 189
  • [9] Using CO2 in supermarket refrigeration
    Sawalha, S
    [J]. ASHRAE JOURNAL, 2005, 47 (08) : 26 - 30
  • [10] Transcritical CO2 Supermarket Refrigeration
    Weber, Collin
    Horning, Harrison
    [J]. ASHRAE JOURNAL, 2015, 57 (10) : 26 - +