Low-intensity pulsed ultrasound treatment for postoperative delayed union or nonunion of long bone fractures

被引:110
|
作者
Jingushi, Seiya
Mizuno, Kosaku
Matsushita, Takashi
Itoman, Moritoshi
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
[2] Teikyo Univ, Sch Med, Dept Orthopaed Surg, Tokyo 173, Japan
[3] Kobe Rosai Hosp, Kobe, Hyogo, Japan
[4] Kitasato Univ, Sch Med, Dept Orthopaed Surg, Sagamihara, Kanagawa 228, Japan
关键词
D O I
10.1007/s00776-006-1080-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Postoperative delayed union and nonunion is the most common complication in fracture treatment. Recent studies have shown an accelerating effect of low-intensity pulsed ultrasound (LIPUS) on fracture repair. However, the indications for delayed union and nonunion are not clear. To clarify the factors which influence the effects of LIPUS, the data from a previous prospective multicenter study on LIPUS treatment for postoperative delayed union and nonunion of long bone fractures were reanalyzed. Methods. Seventy-two cases of long bone fracture, including those of the femur, tibia, humerus, radius, and ulna, were analyzed. The mean time from the most recent operation to the beginning of LIPUS treatment was 11.5 (3-68) months. The relationship between the background factors and the union rate was analyzed using a logistic regression method. In addition, long bone fractures in an upper extremity or in a lower extremity were analyzed separately. Results. The union rate was 75% in all the cases of long bone fracture. There was a significant relationship between the union rate and the period from the most recent operation to the beginning of LIPUS treatment in all cases and in those that had long bone fracture of an upper extremity. There was also a significant relationship between the union rate and the time when a radiological improvement was first observed after the beginning of the treatment in all cases and in those with fractures in a lower extremity. When LIPUS treatment was started within 6 months of the most recent operation, 89.7% of all fractures healed. When an improvement in the radiological changes at the fracture site was observed after 4 months in those cases, then the sensitivity and specificity for union were more than 90%. Conclusions. LIPUS treatment should be started within 6 months of the most recent operation. Because LIPUS has been shown to be effective without causing either serious invasiveness or any undue risk to the patient, it may be considered the treatment of first choice for cases of postoperative delayed union or nonunion.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [21] Low-intensity pulsed ultrasound for treatment of tibial fractures AN ECONOMIC EVALUATION OF THE TRUST STUDY
    Tarride, J. E.
    Hopkins, R. B.
    Blackhouse, G.
    Burke, N.
    Bhandari, M.
    Johal, H.
    Guyatt, G. H.
    Busse, J. W.
    BONE & JOINT JOURNAL, 2017, 99B (11): : 1526 - 1532
  • [22] Successful treatment of nonunion in severe finger injury with low-intensity pulsed ultrasound (LIPUS): a case report
    Michaela Huber
    Lukas Prantl
    Sebastian Gehmert
    Journal of Medical Case Reports, 6 (1)
  • [23] TREATMENT OF DELAYED UNION AND NONUNION OF LONG BONE FRACTURES BY INTERNAL PLATE FIXATION WITH OR WITHOUT AUTOLOGOUS BONE GRAFT
    JAGER, M
    KUSSWETTER, W
    WIRTH, CJ
    WITT, AN
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1973, 77 (03) : 203 - 222
  • [24] Low-intensity pulsed ultrasound in the conservative treatment of pseudoarthrosis
    Pigozzi, F
    Moneta, MR
    Giombini, A
    Giannini, S
    Di Cesare, A
    Fagnani, F
    Mariani, PP
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2004, 44 (02): : 173 - 178
  • [25] Low intensity pulsed ultrasound in the treatment of long bone nonunions: Evaluation of cytokine expression as a tool for objectifying nonunion therapy
    Moghaddam, Arash
    Yildirim, Timur Mert
    Westhauser, Fabian
    Danner, Wolfgang
    Swing, Tyler
    Bruckner, Thomas
    Biglari, Bahram
    JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) : 306 - 312
  • [26] Three key factors affecting treatment results of low-intensity pulsed ultrasound for delayed unions and nonunions: instability, gap size, and atrophic nonunion
    Watanabe, Yoshinobu
    Arai, Yukihiro
    Takenaka, Nobuyuki
    Kobayashi, Makoto
    Matsushita, Takashi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (05) : 803 - 810
  • [27] Fracture Nonunion Treated with Low-Intensity Pulsed Ultrasound and Monitored with Ultrasonography: A Feasibility Study
    Zhang, Peizhen
    Li, Pengdong
    Liao, Shihai
    Li, Xuan
    Chen, Wufan
    Wang, Xiaoyun
    Wang, Qing
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [28] Low-intensity pulsed ultrasound in diaphyseal fractures: clinical application in dogs
    de Sousa, Valeria Lima
    de Alvarenga, Jose
    Padilha Filho, Joao Guilherme
    Canola, Julio Carlos
    Auada Ferrigno, Cassio Ricardo
    Alves, Jose Marcos
    Duarte, Luiz Romariz
    CIENCIA RURAL, 2008, 38 (04): : 1030 - 1037
  • [29] Failed treatment of long bone nonunions with low intensity pulsed ultrasound
    Bahram Biglari
    Timur Mert Yildirim
    Tyler Swing
    Thomas Bruckner
    Wolfgang Danner
    Arash Moghaddam
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1121 - 1134
  • [30] Failed treatment of long bone nonunions with low intensity pulsed ultrasound
    Biglari, Bahram
    Yildirim, Timur Mert
    Swing, Tyler
    Bruckner, Thomas
    Danner, Wolfgang
    Moghaddam, Arash
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (08) : 1121 - 1134