Introduction of a New Parameter for Evaluation of Digital Radiography System Performance

被引:1
|
作者
Choopani, Mohammad Reza [1 ]
Chaparian, Ali [2 ]
机构
[1] Isfahan Univ Med Sci, Fac Paramed, Student Res Comm, Esfahan, Iran
[2] Isfahan Univ Med Sci, Technol Radiol Dept, Esfahan, Iran
来源
JOURNAL OF MEDICAL SIGNALS & SENSORS | 2020年 / 10卷 / 03期
关键词
Contrast detail; contrast-detail radiography phantom; digital radiography; image quality; radiation dose; IMAGE QUALITY; COMPUTED RADIOGRAPHY; DETECTOR;
D O I
10.4103/jmss.JMSS_53_19
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The aim of this study was to compare the image quality and radiation doses in various digital radiography systems using contrast-detail radiography (CDRAD) phantom. Methods: The image quality and radiation dose for seven different digital radiography systems were compared using the CDRAD phantom. Incident air kerma (IAK) values were measured for certain exposure settings in all digital radiography systems. The images from the CDRAD phantom were evaluated by three observers. The results were displayed in the form of a contrast-detail (CD) curve. In addition, the inverse image quality figure (IQFinv)-to-IAK ratios were used for quantitative comparison of different digital radiography system performance. Results: Results of this study showed that the CD curves cannot be suitable criterion for determining the performance of digital radiography systems. For this reason, IQFinv-to-radiation dose (IAK) ratios in a fixed radiation condition were used. The highest performance in terms of producing high-quality images and low radiation dose was related to X-ray unit 1 and the lowest performance was for X-ray unit 5. Conclusion: The ratio of IQFinv to IAK for performance evaluation of digital radiography systems is an innovation of this study. A digital radiography system with a higher IQFinv-to-IAK ratio is associated with lower patient dose and better image quality. Therefore, it is recommended to equip the new imaging centers with the systems that have higher IQFinv-to-IAK ratios.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [41] Clinical evaluation of new workflow-efficient image processing for digital radiography
    Barski, Lori L.
    Couwenhoven, Mary
    Wanga, Xiaohui
    Fletcher-Heath, Lynn
    Dupin, Michael
    Katz, Douglas S.
    Price, Anita P.
    Kranzc, Anca-Onca
    Ortiz, A. Orlando
    Motroni, Betty
    Belfi, Lily
    Foos, David H.
    MEDICAL IMAGING 2007: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2007, 6515
  • [42] DIGITAL RADIOGRAPHY - EXPERIENCES WITH THE SP SYSTEM
    HINTZE, A
    JOTTEN, G
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1986, 145 (01): : 91 - 97
  • [43] USE OF DIGITAL RADIOGRAPHY SYSTEM FOR QUANTITATIVE DIGITAL AUTORADIOGRAPHY
    ALBRIGHT, RE
    SUDDARTH, SA
    FRAM, EK
    HARBURY, OL
    DRAYER, BP
    PUTMAN, CE
    INVESTIGATIVE RADIOLOGY, 1984, 19 (05) : S28 - S28
  • [44] The New Exposure Indicator for Digital Radiography
    Seeram, Euclid
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2014, 45 (02) : 144 - 158
  • [45] DIGITAL CHEST RADIOGRAPHY WITH A LARGE IMAGE INTENSIFIER - EVALUATION OF DIAGNOSTIC PERFORMANCE AND PATIENT EXPOSURE
    MANSSON, LG
    KHEDDACHE, S
    SCHLOSSMAN, D
    BORJESSON, J
    HAKANSSON, E
    MATTSSON, S
    TYLEN, U
    ACTA RADIOLOGICA, 1989, 30 (04) : 337 - 342
  • [46] A new digital radiography system for paintings on canvas and on wooden panels of large dimensions
    Lo Giudice, Alessandro
    Corsi, Jacopo
    Cotto, Giorgio
    Mila, Giorgia
    Re, Alessandro
    Ricci, Chiara
    Sacchi, Roberto
    Visca, Lorenzo
    Zamprotta, Lorenzo
    Pastrone, Nadia
    Albertin, Fauzia
    Brancaccio, Rosa
    Dughera, Giovanni
    Mereu, Paolo
    Staiano, Amedeo
    Nervo, Marco
    Buscaglia, Paola
    Giovagnoli, Annamaria
    Grassi, Novella
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1834 - 1839
  • [47] EVALUATION OF DRY SILVER HARDCOPIES IN DIGITAL RADIOGRAPHY
    TREFLER, M
    MEDICAL PHYSICS, 1985, 12 (04) : 504 - 504
  • [48] Digital radiography in the evaluation of oesophageal motility disorders
    Aly, YA
    CLINICAL RADIOLOGY, 2000, 55 (07) : 561 - 568
  • [49] The Measurement and Evaluation of Standard DQE in Digital Radiography
    Luxiang
    Zhang jun-yi
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2015, 8 : 9 - 12
  • [50] Acquisition and evaluation of radiography images by digital camera
    Cone, SW
    Carucci, LR
    Yu, JX
    Rafiq, A
    Doarn, CR
    Merrell, RC
    TELEMEDICINE JOURNAL AND E-HEALTH, 2005, 11 (02): : 130 - 136