Experimental and Analytical Studies on Lightning Surge Response of 500-kV Transmission Tower

被引:32
|
作者
Motoyama, Hideki [1 ]
Kinoshita, Yasuhide
Nonaka, Katsumasa [2 ]
Baba, Yoshihiro [3 ]
机构
[1] Cent Res Inst Elect Power Ind, Yokosuka, Kanagawa 2400196, Japan
[2] Chubu Elect Power Co Inc, Nagoya, Aichi 4560022, Japan
[3] Doshisha Univ, Kyotanabe 6100321, Japan
关键词
Electromagnetic transient; finite-difference time-domain (FDTD) method; lightning; lightning outage; lightning surge; numerical electromagnetic (EM)-field analysis; tower surge response; transmission line; transmission tower; TIME; EQUATIONS;
D O I
10.1109/TPWRD.2008.2007024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents experimental and analytical studies on the lightning surge response of a 500-kV transmission tower without overhead lines. A number of experimental studies on the lightning surge response of transmission towers have been carried out. However, in these studies, the influence of the current injection angle was ignored. In this paper, an experimental investigation is conducted to assess the influences of the angle and direction of current injection. It is clearly shown that the lightning surge response of the tower depends on the angle and direction of current injection. These experimental results are compared with results calculated using numerical electromagnetic (EM)-field analysis. These calculated results agree with the experimental results. This suggests that numerical EM-field analysis can be employed for evaluating the surge response of a tower. Based on this, the surge response of a tower under a vertical lightning stroke is estimated. It is shown that the surge response under vertical current injection is approximately 30% higher than that under horizontal current injection. It is also shown that the angle and direction of the return stroke are important factors in determining the lightning surge response of a transmission tower.
引用
收藏
页码:2232 / 2239
页数:8
相关论文
共 50 条
  • [41] A new application concept of transmission line arresters to 500-kV lines
    Yamamoto, Y
    Hanada, T
    Omote, T
    Nakura, T
    Hayashi, T
    Fujita, H
    Irie, T
    [J]. 1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 681 - 686
  • [42] Transmission Line Arresters Application for Control of Switching Overvoltages on 500-kV Transmission Line
    Bunov, P.
    Klingbeil, L.
    Schubert, M.
    Gossler, B.
    Biswas, D.
    Hunt, James
    Thallam, R.
    Keri, A. J. F.
    [J]. 2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [43] Electromagnetic Environmental Impact of 500-kV Double -Circuit Transmission Lines
    Qi Jianzhao
    [J]. Electricity, 2011, 22 (01) : 24 - 28
  • [44] Mitigation of the Electric and Magnetic Fields of 500-kV Overhead Transmission Lines
    El Dein, Adel Z.
    Gouda, Osama E.
    Lehtonen, Matti
    Darwish, Mohamed M. F.
    [J]. IEEE ACCESS, 2022, 10 : 33900 - 33908
  • [45] About surge impedance of power transmission line tower at lightning stroke
    Tsitsikyan, George N.
    [J]. EUROCON 2009: INTERNATIONAL IEEE CONFERENCE DEVOTED TO THE 150 ANNIVERSARY OF ALEXANDER S. POPOV, VOLS 1- 4, PROCEEDINGS, 2009, : 1546 - 1548
  • [46] Reliability Evaluation and Weak Component Identification of ±500-kV HVDC Transmission Systems With Double-Circuit Lines on the Same Tower
    Hu, Bo
    Xie, Kaigui
    Tai, Heng-Ming
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (04) : 1716 - 1726
  • [47] Shielding failure lightning protection of 500kV quadruple-circuit transmission lines on the same tower
    Yu, Shifeng
    Ruan, Jiangjun
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1705 - 1708
  • [48] Lightning Flashover Characteristics of a Full-Scale AC 500 kV Transmission Tower with Composite Cross Arms
    Wang, Qian
    Liang, Xidong
    Shen, Yufeng
    Liu, Shuming
    Zuo, Zhou
    Gao, Yanfeng
    [J]. ENGINEERING, 2023, 23 : 130 - 137
  • [49] DIGITAL-COMPUTER STUDIES OF THE SURGE RESPONSE OF A TRANSMISSION-LINE TOWER
    HAMZA, ASH
    ABDELGAWAD, NMK
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1994, 35 (12) : 1097 - 1105
  • [50] Characteristic of lightning shielding failure for 500 kV AC transmission lines with quadruple-circuits on one tower
    Su, Hong-Mei
    Liu, Xiao-Dong
    Wei, Guo-Ping
    Chai, Ya-Jing
    Li, Xue
    Zhou, Wen-Jun
    [J]. Gaodianya Jishu/High Voltage Engineering, 2007, 33 (11): : 205 - 208