Comparison of FibroTouch and FibroScan for staging fibrosis in chronic liver disease: Single-center prospective study

被引:38
|
作者
Xu, Yumin [1 ]
Liu, Yuhan [1 ]
Cao, Zhujun [1 ]
Wang, Lin [1 ]
Li, Ziqiang [1 ]
Sheng, Zike [1 ]
Cai, Wei [1 ]
Wang, Hui [1 ]
Bao, Shisan [2 ,3 ]
Xie, Qing [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Infect Dis, Shanghai, Peoples R China
[2] Univ Sydney, Charles Perkins Ctr, Discipline Pathol, Sch Med Sci, Sydney, NSW, Australia
[3] Univ Sydney, Charles Perkins Ctr, Bosch Inst, Sydney, NSW, Australia
基金
中国国家自然科学基金;
关键词
FibroScan; FibroTouch; Liver fibrosis; Liver stiffness; SIMPLE NONINVASIVE INDEX; GOLGI PROTEIN 73; STIFFNESS MEASUREMENT; HEPATITIS; STEATOHEPATITIS; EPIDEMIOLOGY; DIAGNOSIS; BIOMARKER; PREDICT; AREAS;
D O I
10.1016/j.dld.2019.02.009
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The aim of this study was to compare the diagnostic accuracy of the FibroTouch and FibroScan in patients with chronic liver disease (CLD) for staging fibrosis. Methods: A prospective study was conducted in 435 CLD patients between 2014 and 2017. Index tests (FibroTouch, FibroScan, APRI, and FIB-4 score) and a reference standard (liver biopsy) were performed within one week. Results: The area under the receiver operating curve (AUROC) of the FibroTouch was similar with that of the FibroScan for the diagnosis of significant fibrosis, severe fibrosis, or cirrhosis; however, the AUROC of the FibroTouch was higher than that of APRI or FIB-4 (p<0.001). There was a significant correlation (rho = 0.85, p<0.001) between the FibroTouch and FibroScan for liver stiffness. The overall diagnostic accuracy of FibroTouch for significant fibrosis, severe fibrosis, or cirrhosis was 73.3%, 83.2%, or 84.1%, respectively. No significant differences between the FibroTouch and FibroScan were detected regarding the sensitivity, specificity, negative predictive value, positive predictive value, and accuracy. The optimal cut-off values for each stage of fibrosis were similar between the FibroTouch and FibroScan. Conclusion: The FibroTouch is a valuable diagnostic tool for diagnosing liver fibrosis with good diagnostic accuracy which was comparable with that of the FibroScan, but superior to that of the APRI and FIB-4. (C) 2019 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1323 / 1329
页数:7
相关论文
共 50 条
  • [31] Photodynamic Skincare: A Prospective Single-Center Study
    Young, Jade N.
    Yearwood, Katrina
    Scali, Julia
    Sanchez, Arlene
    Juhasz, Margit
    Marmur, Ellen S.
    JOURNAL OF DRUGS IN DERMATOLOGY, 2024, 23 (05) : 332 - 337
  • [32] Noninvasive Methods for Detecting Advanced Liver Fibrosis and Cirrhosis in Patients with Chronic Hepatitis B: A Single-Center Retrospective Study
    Cheng, Ran
    Tan, Ning
    Luo, Hao
    Kang, Qian
    Xu, Xiaoyuan
    INFECTION AND DRUG RESISTANCE, 2023, 16 : 6323 - 6331
  • [33] Favorable impact of extracorporeal photopheresis in acute and chronic graft versus host disease: Prospective single-center study
    Sakellari, Ioanna
    Gavriilaki, Eleni
    Batsis, Ioannis
    Mallouri, Despina
    Panteliadou, Alkistis-Kira
    Lazaridou, Andriana
    Vardi, Anna
    Constantinou, Varnavas
    Yannaki, Evangelia
    Papalexandri, Apostolia
    Kaloyannidis, Panayotis
    Smias, Christos
    Anagnostopoulos, Achilles
    JOURNAL OF CLINICAL APHERESIS, 2018, 33 (06) : 654 - 660
  • [34] Diagnostic accuracy of acoustic radiation force impulse elastography (ARFI) in comparison to other non-invasive modalities in staging of liver fibrosis in chronic HCV patients: single-center experience
    Shereen Abdel Alem
    Zeinab Abdellatif
    Mahasen Mabrouk
    Naglaa Zayed
    Aisha Elsharkawy
    Marwa Khairy
    Sherief Musa
    Ismail Anwar
    Ayman Yosry
    Abdominal Radiology, 2019, 44 : 2751 - 2758
  • [35] PROSPECTIVE INDEPENDENT VALIDATION AND COMPARISON OF 10 BIOMAKERS AND TRANSIENT ELASTROGRAPHY (FIBROSCAN™) FOR LIVER FIBROSIS ASSESSMENT IN PATIENTS WITH CHRONIC HEPATITIS C
    Zarski, J. P.
    Sturm, N.
    Guechot, J.
    Paris, A.
    JOURNAL OF HEPATOLOGY, 2010, 52 : S175 - S176
  • [36] Diagnostic accuracy of acoustic radiation force impulse elastography (ARFI) in comparison to other non-invasive modalities in staging of liver fibrosis in chronic HCV patients: single-center experience
    Alem, Shereen Abdel
    Abdellatif, Zeinab
    Mabrouk, Mahasen
    Zayed, Naglaa
    Elsharkawy, Aisha
    Khairy, Marwa
    Musa, Sherief
    Anwar, Ismail
    Yosry, Ayman
    ABDOMINAL RADIOLOGY, 2019, 44 (08) : 2751 - 2758
  • [37] Antiphospholipid antibodies in Crohn's disease: Results of a prospective single-center study
    Serghini, M.
    Ben Youssef, H.
    Baccouche, H.
    Hafi, M.
    Labidy, A.
    Ben Mustapha, N.
    Fekih, M.
    Boubaker, J.
    JOURNAL OF CROHNS & COLITIS, 2021, 15 : S290 - S291
  • [38] EFFECT OF KETOGENIC DIET ON GASTROESOPHAGEAL REFLUX DISEASE: A SINGLE-CENTER PROSPECTIVE STUDY
    Latorre-Rodriguez, Andres R.
    Mittal, Sumeet K.
    Munir, Seema
    GASTROENTEROLOGY, 2023, 164 (06) : S1546 - S1546
  • [39] Spleen stiffness measurement across the spectrum of chronic liver disease: A single-center experience
    Romero, S.
    Thompson, A. J.
    Howell, J.
    Ryan, M.
    Mei, S. L. Chen Yi
    Croagh, C.
    Demediuk, B.
    Papaluca, T.
    Desmond, P.
    Holmes, J.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2022, 37 : 95 - 96
  • [40] Protocol of Kupffer phase whole liver scan for metastases: A single-center prospective study
    Wu, Qiong
    Liu, Yilun
    Sun, Di
    Wang, Yan
    Wei, Xiaoer
    Li, Jing
    Liu, Beibei
    Wang, Shuhao
    Zhou, Yan
    Hu, Haiyan
    Zhang, Rui
    Jiao, Qiong
    Li, Yi
    Ying, Tao
    FRONTIERS IN MEDICINE, 2022, 9