OBJECTIVE, Our study was undertaken to develop diagnostic rules and to assess the reproducibility of dynamic and morphologic parameters for the ch;characterization of suspicious breast lesions using dynamic high-spatial-resolution MR imagine. MATERIALS AND METHODS. Fifty-seven patients with suspicious mammographic or palpable findings underwent preoperative contrast-enhanced MR imaging of the breast using a three-time-point method of acquisition. Each lesion was prospectively analyzed by two independent radiologists for morphologic and visual dynamic enhancement characteristics. A classification and regression tree was used to examine the optimal order, cutoff points, and combination of imaging parameters to build a diagnostic rule separating benign from malignant lesions using histopathology findings as the standard of reference, Kappa statistics were used to determine observer variability. RESULTS, Among 23 benign and 33 malignant lesions (12 invasive, three ductal carcinomaa in situ, and 19 mined cancer), margin morphology (p = 0.001) and enhancement pattern (p = 0.001) were the most significant MR imaging findings for lesion characterization. Focal mass lesions were classified as malignant when spiculated margins or both the washout enhancement pattern and "nonsmooth" margins were present. Interobserver agreement was almost perfect for washout pattern and substantial for margin assessment. In the limited population tested retrospectively, the diagnostic rule yielded a sensitivity and positive predictive value of 97% each and a specificity and negative predictive value of 96% each. CONCLUSION. The washout enhancement pattern combined with lesion margin assessment on dynamic: contrast-enhanced high-resolution MR imaging of the breast allows reproducible lesion characterization and may be a highly specific diagnostic tool.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [31] A combined high temporal and high spatial resolution 3 Tesla MR imaging protocol for the assessment of breast lesions: initial results
    Pinker, K.
    Grabner, G.
    Bogner, W.
    Gruber, S.
    Trattnig, S.
    Heinz-Peer, G.
    Fitzal, F.
    Pluschnig, U.
    Rudas, M.
    Helbich, T. H.
    EJC SUPPLEMENTS, 2010, 8 (03): : 236 - 236
  • [32] A Combined High Temporal and High Spatial Resolution 3 Tesla MR Imaging Protocol for the Assessment of Breast Lesions Initial Results
    Pinker, Katja
    Grabner, Gunther
    Bogner, Wolfgang
    Gruber, Stephan
    Szomolanyi, Pavol
    Trattnig, Siegfried
    Heinz-Peer, Gertraud
    Weber, Michael
    Fitzal, Florian
    Pluschnig, Ursula
    Rudas, Margarethe
    Helbich, Thomas
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 553 - 558
  • [33] Improved diagnostic accuracy of breast lesions with combined rapid dynamic and high-resolution contrast-enhanced MR imaging: A multivariate ROC analysis
    Plevritis, SK
    Daniel, BL
    Herfkens, RJ
    Glover, GH
    Yen, Y
    Leong, CS
    RADIOLOGY, 1997, 205 : 95 - 95
  • [34] High temporal resolution MR imaging in the assessment of mammographically suspicious microcalcifications
    Newstead, GM
    Yang, C
    Medved, M
    Abe, H
    Karczmar, GS
    Schmidt, RA
    Zamora, MA
    Foxley, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 56 - 56
  • [35] The spinal cord in multiple sclerosis: Relationship of high-spatial-resolution quantitative MR imaging findings to histopathologic results
    Bot, JCJ
    Blezer, ELA
    Kamphorst, W
    Nijeholt, GJLA
    Ader, HJ
    Castelijns, JA
    Ig, KN
    Bergers, E
    Ravid, R
    Polman, C
    Barkhof, F
    RADIOLOGY, 2004, 233 (02) : 531 - 540
  • [36] Rectal carcinoma: High-spatial-resolution MR imaging and T2 quantification in rectal cancer specimens
    Stollfuss, Jens C.
    Becker, Karen
    Sendler, Andreas
    Seidl, Stefan
    Settles, Marcus
    Auer, Florian
    Beer, Ambros
    Rummeny, Ernst J.
    Woertler, Klaus
    RADIOLOGY, 2006, 241 (01) : 132 - 141
  • [37] High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: Initial experience
    Nikolaou, Konstantin
    Kramer, Harald
    Grosse, Christina
    Clevert, Dirk
    Dietrich, Olaf
    Hartmann, Mike
    Chamberlin, Paul
    Assmann, Stefan
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    RADIOLOGY, 2006, 241 (03) : 861 - 872
  • [38] Atherosclerotic Plaque Progression in Carotid Arteries: Monitoring with High-Spatial-Resolution MR Imaging-Multicenter Trial
    Boussel, Loic
    Arora, Sandeep
    Rapp, Joseph
    Rutt, Brian
    Huston, John
    Parker, Dennis
    Yuan, Chun
    Bassiouny, Hisham
    Saloner, David
    RADIOLOGY, 2009, 252 (03) : 789 - 796
  • [39] High-spatial-resolution spectral imaging of acute neocortical seizures in rats
    Chen, James W.
    EPILEPSIA, 2006, 47 : 208 - 208
  • [40] Rapid high-spatial-resolution imaging of buried landmines using ESPI
    Sabatier, JM
    Aranchuk, V
    Alberts, WCK
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS IX, PTS 1 AND 2, 2004, 5415 : 14 - 20