Artifacts in optical coherence tomography (OCT) imaging of the retina

被引:7
|
作者
Strauss, R. W.
Scholz, F.
Ulbig, M. W.
Kampik, A.
Neubauer, A. S.
机构
[1] Univ Munich, Augenklin, D-80336 Munich, Germany
[2] Datamed Consulting, Hamburg, Germany
关键词
optical coherence tomography (OCT); artifact; error; image processing;
D O I
10.1055/s-2006-927274
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to investigate artifacts of OCT scans and of software analysis for retinal cross-section scans in a specialised retina clinic setting. Methods: A total of 205 vertical cross-hair OCT scans of retinal Stratus OCTs were randomly chosen from the database. All scans had been performed by one experienced technician. There were 75 (37%) normal findings, the remaining scans showed various types of retinal pathology: All scanning artifacts were analysed. Retinal thickness of all scans was measured automatically at the centre of the macula using two different software algorithms: the instrument's built-in "Stratus OCT Viewer V 4.01" and the stand-alone application "Datamedical OCTview V 3.5" (Datamedical Consulting, Hamburg). Errors of the software to correctly identify the retinal surface and the outer highly reflective layer were assigned into three categories: none, minor error (no influence on measurements) and major error. Results: A total of 7.3% of all OCT scans showed scanning artifacts: 5 motion artifacts, 9 scans with low signal intensity and I decentred scan. Scanning artifacts significantly increased the frequency of software errors (p = 0,012). The presence of retinal pathology also increased the number of errors (p = 0,004). Software analysis yielded a total of 20 major and 2 minor errors for the Stratus OCT (overall 10.7%) and 32 major and 64 minor errors for the Datamedical Viewer (p < 0.001). Measurements by Datamedical OCT view were a mean of 57 micron higher due to a different definition of the outer retinal border. Retinal pathologies significantly increased the likelihood of software errors for both algorithms (both p < 0.01), most critical were macular holes and changes in age-related macular degeneration. Conclusion: Scanning artifacts were associated with a significantly higher frequency of software errors. As artifacts of scans and software occur frequently, the interpretation of OCT scans requires special attention to artifacts.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 50 条
  • [21] Simultaneous fundus imaging and optical coherence tomography of the mouse retina
    Kocaoglu, Omer P.
    Uhlhorn, Stephen R.
    Hernandez, Eleut
    Juarez, Roger A.
    Will, Russell
    Parel, Jean-Marie
    Manns, Fabrice
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (03) : 1283 - 1289
  • [22] Intraoperative Optical Coherence Tomography Imaging of the Peripheral Vitreous and Retina
    Nishitsuka, Koichi
    Nishi, Katsuhiro
    Namba, Hiroyuki
    Kaneko, Yutaka
    Yamashita, Hidetoshi
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (03): : E20 - E22
  • [23] Development of an Optical Coherence Tomography System for Mouse Retina Imaging
    Dong, Rongyao
    Ma, Yanhong
    Song, Tianqi
    Zhou, Mingliang
    Wang, Shuai
    Zhang, Pengfei
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (21):
  • [24] Artifacts in macular optical coherence tomography
    Bazvand, Fatemeh
    Ghassemi, Fariba
    [J]. JOURNAL OF CURRENT OPHTHALMOLOGY, 2020, 32 (02): : 123 - 131
  • [25] An overview of methods to mitigate artifacts in optical coherence tomography imaging of the skin
    Adabi, Saba
    Fotouhi, Audrey
    Xu, Qiuyun
    Daveluy, Steve
    Mehregan, Darius
    Podoleanu, Adrian
    Nasiriavanaki, Mohammadreza
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2018, 24 (02) : 265 - 273
  • [27] Artifacts in Optical Coherence Tomography Angiography
    Anvari, Pasha
    Ashrafkhorasani, Maryam
    Habibi, Abbas
    Falavarjani, Khalil Ghasemi
    [J]. JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2021, 16 (02) : 271 - 286
  • [28] Heartbeat-Induced Axial Motion Artifacts in Optical Coherence Tomography Measurements of the Retina
    de Kinkelder, Roy
    Kalkman, Jeroen
    Faber, Dirk J.
    Schraa, Olaf
    Kok, Pauline H. B.
    Verbraak, Frank D.
    van Leeuwen, Ton G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (06) : 3908 - 3913
  • [29] In vivo imaging of inner plexiform layer (IPL) stratification in the human retina with visible light Optical Coherence Tomography (OCT)
    Srinivasan, Vivek
    Zhang, Tingwei
    Kho, Aaron
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [30] IMAGING OF MACULAR DEGENERATION AND CHOROIDAL NEOVASCULARIZATION WITH OPTICAL COHERENCE TOMOGRAPHY (OCT)
    WONG, C
    HEE, MR
    PULIAFITO, CA
    DUKER, JS
    REICHEL, E
    RUTLEDGE, B
    SCHUMAN, JS
    SWANSON, EA
    FUJIMOTO, JG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S240 - S240