Artifacts in optical coherence tomography (OCT) imaging of the retina

被引:7
|
作者
Strauss, R. W.
Scholz, F.
Ulbig, M. W.
Kampik, A.
Neubauer, A. S.
机构
[1] Univ Munich, Augenklin, D-80336 Munich, Germany
[2] Datamed Consulting, Hamburg, Germany
关键词
optical coherence tomography (OCT); artifact; error; image processing;
D O I
10.1055/s-2006-927274
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to investigate artifacts of OCT scans and of software analysis for retinal cross-section scans in a specialised retina clinic setting. Methods: A total of 205 vertical cross-hair OCT scans of retinal Stratus OCTs were randomly chosen from the database. All scans had been performed by one experienced technician. There were 75 (37%) normal findings, the remaining scans showed various types of retinal pathology: All scanning artifacts were analysed. Retinal thickness of all scans was measured automatically at the centre of the macula using two different software algorithms: the instrument's built-in "Stratus OCT Viewer V 4.01" and the stand-alone application "Datamedical OCTview V 3.5" (Datamedical Consulting, Hamburg). Errors of the software to correctly identify the retinal surface and the outer highly reflective layer were assigned into three categories: none, minor error (no influence on measurements) and major error. Results: A total of 7.3% of all OCT scans showed scanning artifacts: 5 motion artifacts, 9 scans with low signal intensity and I decentred scan. Scanning artifacts significantly increased the frequency of software errors (p = 0,012). The presence of retinal pathology also increased the number of errors (p = 0,004). Software analysis yielded a total of 20 major and 2 minor errors for the Stratus OCT (overall 10.7%) and 32 major and 64 minor errors for the Datamedical Viewer (p < 0.001). Measurements by Datamedical OCT view were a mean of 57 micron higher due to a different definition of the outer retinal border. Retinal pathologies significantly increased the likelihood of software errors for both algorithms (both p < 0.01), most critical were macular holes and changes in age-related macular degeneration. Conclusion: Scanning artifacts were associated with a significantly higher frequency of software errors. As artifacts of scans and software occur frequently, the interpretation of OCT scans requires special attention to artifacts.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 50 条
  • [1] From Imaging the Brain to Imaging the Retina: Optical Coherence Tomography (OCT) in Schizophrenia
    Schoenfeldt-Lecuona, Carlos
    Kregel, Thomas
    Schmidt, Arno
    Pinkhardt, Elmar H.
    Lauda, Florian
    Kassubek, Jan
    Connemann, Bernhard J.
    Freudenmann, Roland W.
    Gahr, Maximilian
    [J]. SCHIZOPHRENIA BULLETIN, 2016, 42 (01) : 9 - 14
  • [2] Optical Coherence Tomography (OCT) Imaging Technology
    Milanovic, Ljubica
    Milenkovic, Strahinja
    Petrovic, Nenad
    Grujovic, Nenad
    Slavkovic, Vukasin
    Zivic, Fatima
    [J]. 2021 IEEE 21ST INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (IEEE BIBE 2021), 2021,
  • [3] Optical coherence tomography imaging of the pediatric retina
    Cai, Sophie
    Therattil, Anthony
    Vajzovic, Lejla
    [J]. JOURNAL OF AAPOS, 2020, 24 (05): : 261 - 267
  • [4] Cancellation of coherent artifacts in optical coherence tomography imaging
    Piao, Daqing
    Zhu, Quing
    Dutta, Niloy K.
    Yan, Shikui
    Otis, Linda L.
    [J]. Applied Optics, 2001, 40 (28): : 5124 - 5131
  • [5] Cancellation of coherent artifacts in optical coherence tomography imaging
    Piao, DQ
    Zhu, QI
    Dutta, NK
    Yan, SK
    Otis, LL
    [J]. APPLIED OPTICS, 2001, 40 (28) : 5124 - 5131
  • [6] Imaging of atherosclerotic plaques by Optical Coherence Tomography (OCT)
    Perrée, J
    van Leeuwen, TG
    Pasterkamp, G
    Izatt, JA
    [J]. LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS X, 2000, 3907 : 522 - 527
  • [7] Imaging of actinic porokeratosis by optical coherence tomography (OCT)
    von Felbert, V.
    Neis, M.
    Megahed, M.
    Spoeler, F.
    [J]. HAUTARZT, 2008, 59 (11): : 877 - 879
  • [8] Optical coherence tomography (OCT) imaging in intraocular inflammations
    Walter, A
    Bialasiewicz, AA
    Hassenstein, A
    Schaudig, U
    Richard, G
    [J]. SOE '97 - XI CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, VOLS 1 AND 2, 1997, : 1583 - 1585
  • [9] Adaptive optics optical coherence tomography for retina imaging
    史国华
    戴云
    王玲
    丁志华
    饶学军
    张雨东
    [J]. Chinese Optics Letters, 2008, (06) : 424 - 425
  • [10] INVIVO IMAGING OF THE HUMAN RETINA WITH OPTICAL COHERENCE TOMOGRAPHY
    IZATT, JA
    SWANSON, EA
    HEE, MR
    HUANG, D
    LIN, CP
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 761 - 761