Comparison between and evaluation of some methods for the assessment of the sphericity of pellets

被引:25
|
作者
Eriksson, M
Alderborn, G
Nystrom, C
Podczeck, F
Newton, JM
机构
[1] UNIV UPPSALA,DEPT PHARM,S-75123 UPPSALA,SWEDEN
[2] UNIV LONDON,SCH PHARM,DEPT PHARMACEUT,LONDON WC1N 1AX,ENGLAND
关键词
air permeametry; aspect ratio; eccentricity factor; Heywood shape factor; image-analysis; one-plane critical stability; pellets; shape analysis;
D O I
10.1016/S0378-5173(96)04845-4
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The shape of pellets, prepared by extrusion-spheronisation, has been assessed by the analysis of the two-dimensional images in the form of an elongation ratio (direct microscopic measurement), aspect ratio (image analysis), one-plane critical stability (OPCS) and a shape factor e(R) (Podczeck and Newton, 1994) plus 3-dimensional characterisation by the Heywood shape coefficient and a permeametry shape factor (Eriksson et al., 1993). Steel ball bearings were used as a standard for each of the methods. The elongation and aspect ratio proved to be poor methods of distinguishing between the variations in shape of pellets within a batch nor particularly sensitive to measure differences between batches. OPCS and the shape factor, e(R), were more distinguishing in terms of detecting batch differences and inter-batch differences. The two-dimensional image methods ranked the batches in equivalent order of ranking. The Heywood shape coefficient gave the same ranking but the permeametry shape factor gave a significantly different ranking which could be associated with the surface texture of the spheres. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [31] COMPARISON OF SOME TECHNICAL METHODS FOR THE EVALUATION OF WHOLE-BODY VIBRATION
    HANSSON, JE
    WIKSTROM, BO
    ERGONOMICS, 1981, 24 (12) : 953 - 963
  • [33] Comparison of Bond Strength Evaluation Methods Between Pavement Layers
    Haslett, Katie E.
    Robinson, Zachary
    Wielinski, Jason
    TRANSPORTATION RESEARCH RECORD, 2022,
  • [34] COMPARISON BETWEEN DIFFERENT METHODS IN FLOW CYTOMETRY DATA EVALUATION
    Viola, Nadia
    Bartoloni, Lucia
    Novello, Enrica
    Pantano, Giorgia
    Sanzari, Maria Colomba
    Ortolani, Claudio
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (06) : 439 - 440
  • [35] Nutritional evaluation of cirrhotic patients: comparison between several methods
    Nunes, Flavia Feijo
    Fernandes, Sabrina Alves
    Bertolini, Cristine Maria
    Rabito, Estela Iraci
    Andreatta Gottschall, Catarina Bertaso
    SCIENTIA MEDICA, 2012, 22 (01) : 12 - 17
  • [36] Comparison between methods of evaluation of soybean mechanized harvesting losses
    Compagnon, Ariel Muncio
    da Silva, Rouverson Pereira
    Cassia, Marcelo Tufaile
    Graat, Denny
    Voltarelli, Murilo Aparecido
    SCIENTIA AGROPECUARIA, 2012, 3 (03) : 215 - 223
  • [38] Comparison between two methods for evaluation of the dialysis dose quality
    Inoue, Kelly Cristina
    Kuroda, Cristina Negumi
    Nakayama, Kazumi Gelia
    Dell'Agnolo, Catia Milene
    Matsuda, Laura Mitsue
    ACTA PAULISTA DE ENFERMAGEM, 2009, 22 : 494 - 496
  • [39] COMPARISON BETWEEN SOME DETERMINATION METHODS OF RESIDUAL STYRENE IN PLASTIC SCINTILLATORS
    BEZUGLYI, VD
    PONOMAREV, YP
    GUNDER, OA
    BITEMAN, VB
    SENCHISHIN, VG
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1988, 43 (03): : 419 - 422
  • [40] Thermographic assessment of skin prick tests in comparison with the routine evaluation methods
    Rok, Tomasz
    Rokita, Eugeniusz
    Taton, Grzegorz
    Guzik, Tomasz
    Sliwa, Tomasz
    POSTEPY DERMATOLOGII I ALERGOLOGII, 2016, 33 (03): : 193 - 198